cs.CLOct 26, 2026

EXCISE: Locating and Excising Distracting Sentences in Medical Question Answering

Authors: Yerim Hong, Sohyun Son, Heeseung Chung, Mujeen Sung

Organizations: Kyung Hee University

Abstract

Language models are increasingly considered for clinical decision support, where their answers should be grounded in clinical evidence and remain robust to irrelevant information. Prior work shows that a single irrelevant sentence can lower the accuracy of medical models, but not where inside the model its effect can be removed, or how to do so without knowing which sentence it is. We find that blocking attention to a known distractor restores the answer, whereas head masking can suppress correct answers. We also show that the model's hidden states mark the distractor as the sentence that least fits the case even when the model follows it. To remove a distractor's effect without knowing which sentence it is, we propose EXCISE, an inference-time method that blocks the sentence most influencing the answer, but only if the model's hidden states mark it as inconsistent with the case. On MedQA-TD (MedQA with Targeted Distractors), a benchmark we construct in which each distractor targets a specific wrong option, EXCISE gains 16.7-22.8 accuracy points at a 1.5-2.1-point cost on the same questions without distractors, outperforming prompting, rewriting, and steering baselines for all three models. Its gains extend to MedDistractQA and BiasMedQA, as well as chain-of-thought generation.

Figures & tables

Appendix figures & tables22 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 9, 2026

An Empirical Study of Development-Tuned Representation Sensitivity for Medical QA Data Selection

We study medical question-answering (QA) data selection when a developer already has questions, labels, and auxiliary explanatory texts but can retain only BB examples for a final LoRA update. Representation-Sensitivity Prioritization (RSP) first restricts the candidate bank to its top-4B4B predictive-entropy examples, then combines the frequency of answer flips with non-flipping contraction of the top-two answer margin under hidden-state perturbations. We evaluate this operational score on five medical QA datasets with google/medgemma-4b-it, B=128B=128, and three seed branches. After removing four MedExpQA test questions that also occur in its acquisition pool, dataset-specific development-tuned RSP attains the highest observed five-dataset mean accuracy (53.44%) and Macro-F1 (48.21%) among the evaluated selectors. Relative to random selection within the same entropy-restricted pool, the descriptive differences are +1.49 and +2.10 percentage points, respectively; paired 95% bootstrap intervals include zero. The audit mixes benchmarks with different relationships to documented backbone post-training sources, and the same test cohorts had been used in earlier analyses before the expanded tuning grid was designed. Results are therefore exploratory, modest, and dataset-dependent rather than evidence of statistical superiority. RSP point estimates also exceed an archived no-update reference, but unpinned model revisions and incomplete historical input identifiers limit attribution of that difference to fine-tuning. Because every selected training example includes auxiliary text and no matched answer-only control is evaluated, the experiments also do not identify a causal benefit from auxiliary-text conditioning itself.
May 31, 2026

HypothesisMed: Inference-Time Answer Fusion and Structured Hypothesis-Space Reporting for Biomedical Question Answering

Biomedical question answering with large language models is commonly evaluated using answer accuracy, but answer accuracy alone does not indicate whether a model can produce parseable outputs, follow structured reliability instructions, recognize weak answer spaces, or avoid confident incorrect commitments. This paper presents HypothesisMed, an inference-time reliability pipeline for biomedical multiple-choice question answering. It combines direct, chain-of-thought, HypothesisMed-v3 prompting, and answer fusion. The final answer is selected by fusion, while HypothesisMed-v3 supplies SPACE labels and confidence information. SPACE labels mark the answer space as VALID, INCOMPLETE, or CONTRADICTED. We evaluate Qwen2.5-7B, Phi-4-mini, DeepSeek-R1-32B, and BioMistral-7B on MedQA, MedMCQA, and PubMedQA using 1,000 examples per dataset. The pipeline improves weighted accuracy over each model's best direct or chain-of-thought baseline while increasing parse and SPACE coverage. We also scale evaluation to Qwen2.5-7B and Phi-4-mini using 10,183 examples per model. Fusion improves Phi-4-mini accuracy from 0.4296 to 0.5192, while Qwen2.5-7B chain-of-thought remains slightly higher in answer accuracy. However, Qwen2.5-7B fusion achieves complete parse and SPACE coverage with much lower false commitment. A 12,000-example SPACE stress test shows answer-space diagnosis remains difficult, with SPACE accuracy of 0.3074 for Qwen2.5-7B and 0.4168 for Phi-4-mini. These results show that answer accuracy, parseability, structured reliability reporting, calibration behavior, and false-commitment behavior are separable capabilities. The main contribution is not a universal state-of-the-art claim, but a reproducible inference-time framework for evaluating biomedical question answering models as auditable workflow components under structured reliability constraints.
Mar 5, 2026

Med-V1: Small Language Models for Zero-shot and Scalable Biomedical Evidence Attribution

Assessing whether an article supports an assertion is essential for hallucination detection and claim verification. While large language models (LLMs) have the potential to automate this task, achieving strong performance requires frontier models such as GPT-5 that are prohibitively expensive to deploy at scale. To efficiently perform biomedical evidence attribution, we present Med-V1, a family of small language models with only three billion parameters. Trained on high-quality synthetic data newly developed in this study, Med-V1 substantially outperforms (+27.0% to +71.3%) its base models on five biomedical benchmarks unified into a verification format. Despite its smaller size, Med-V1 performs comparably to frontier LLMs such as GPT-5, along with high-quality explanations for its predictions. We use Med-V1 to conduct a first-of-its-kind use case study that quantifies hallucinations in LLM-generated answers under different citation instructions. Results show that the format instruction strongly affects citation validity and hallucination, with GPT-5 generating more claims but exhibiting hallucination rates similar to GPT-4o. Additionally, we present a second use case showing that Med-V1 can automatically identify high-stakes evidence misattributions in clinical practice guidelines, revealing potentially negative public health impacts that are otherwise challenging to identify at scale. Overall, Med-V1 provides an efficient and accurate lightweight alternative to frontier LLMs for practical, real-world biomedical evidence attribution. Med-V1 is available at https://github.com/NLM-DIR/Med-V1.