cs.CVNov 3, 2026

From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation

Authors: Efthymios Georgiou, Ioannis Kakogeorgiou, Sarah Brüningk

Organizations: Department of Digital Medicine, University of Bern, Switzerland · Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Switzerland · IIT, National Centre for Scientific Research “Demokritos”, Greece

Abstract

Transfer learning from natural images is standard in supervised and increasingly adopted in self-supervised medical image analysis, but its role in generative modelling, and in particular diffusion denoisers, remains underexplored. Medical diffusion models typically train the denoiser from scratch, with no systematic evaluation of natural-image transfer. We analyse this across latent and pixel paradigms, model sizes (131M-952M) and two radiology datasets (RadImageNet, BraTS), and ask which aspects of transfer support generation. We find that: i) Natural-image initialisation consistently improves generation, by 21-34% relative gFID in pixel space against 14% in latent space, where the tokeniser supplies much of the prior. gFID gains mirror downstream pathology classification and radiomic-feature FD, both proxies for clinical fidelity. ii) Benefits reflect spatial structure, not semantics: semantic probing does not predict generation quality, whereas a spatial-structure metric adapted to internal denoiser representations tracks gFID at ∣r∣=0.85|r|=0.85, positioning spatial organisation as a channel through which pretraining manifests. iii) Mixed-domain denoiser training shows that natural and medical images share similar layer-wise representations up to the late blocks, and mixing natural images into medical training improves fidelity. iv) Transfer benefit is tied to natural image initialisation, outperforming in-domain medical pretraining and several reinitialisation schemes. Overall, natural image denoisers transfer positively to medical ones in our setup. Code is available at https://github.com/CAIROLab-Bern/rad-dit

Figures & tables

Explore similar work

Oct 19, 2026

3D Diffusion Models for Medical Imaging

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.
Mar 17, 2026

CompDiff enables fair and zero shot medical image generation across demographic intersections through compositional diffusion

Medical image generators trained on imbalanced data can fail at demographic intersections absent from training. We introduce CompDiff, which encodes age, sex and race separately and composes supervised demographic tokens alongside clinical text. Across chest radiographs and fundus images, CompDiff improves overall and subgroup fidelity relative to prompt conditioning (RoentGen-v2) and loss reweighting (FairDiffusion). It generalises in zero-shot generation to 16 chest X-ray intersections excluded from training, achieving the lowest mean FID-RadImageNet in every intersection. In a blinded reader study of these unseen intersections, two radiologists gave CompDiff the highest mean scores among generators for anatomical realism and agreement with the clinical impression, and selected its images most often as the most realistic. Pretraining with CompDiff images improved downstream classification, while CompDiff audit cohorts reduced estimation error on rare intersections. These findings support compositional demographic conditioning for extending medical image synthesis to underserved populations. Code: https://github.com/mahmoudibrahim98/CompDiff
Apr 14, 2026

Domain-Specific Latent Representations Improve the Fidelity of Diffusion-Based Medical Image Super-Resolution

Latent diffusion models for medical image super-resolution universally inherit variational autoencoders designed for natural photographs. We show that this default choice, not the diffusion architecture, is the dominant constraint on reconstruction quality. In a controlled experiment holding all other pipeline components fixed, replacing the generic Stable Diffusion VAE with MedVAE, a domain-specific autoencoder pretrained on more than 1.6 million medical images, yields +2.91 to +3.29 dB PSNR improvement across knee MRI, brain MRI, and chest X-ray (n = 1,820; Cohen's d = 1.37 to 1.86, all p < 10^{-20}, Wilcoxon signed-rank). Wavelet decomposition localises the advantage to the finest spatial frequency bands encoding anatomically relevant fine structure. Ablations across inference schedules, prediction targets, and generative architectures confirm the gap is stable within plus or minus 0.15 dB, while hallucination rates remain comparable between methods (Cohen's h < 0.02 across all datasets), establishing that reconstruction fidelity and generative hallucination are governed by independent pipeline components. These results provide a practical screening criterion: autoencoder reconstruction quality, measurable without diffusion training, predicts downstream SR performance (R^2 = 0.67), suggesting that domain-specific VAE selection should precede diffusion architecture search. Code and trained model weights are publicly available at https://github.com/sebasmos/latent-sr.