cs.CVNov 5, 2026

An Anatomy-guided 3D Segmentation Pipeline for Prostate Surgical Phantoms from CT Scans

Authors: Iven Chen, Kuan-I Chung, Ayberk Acar, Susheela Sharma Stern, Alejandro O. Chara, Jie Ying Wu, Daniel Moyer

Organizations: Department of Computer Science, Vanderbilt University, Nashville, TN, USA · Vanderbilt Institute for Surgery and Engineering, Nashville, TN, USA · Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA · Vanderbilt University Medical Center, Nashville, TN, USA

Abstract

Full autonomy has been a long-term goal in robotic surgery and a near-to-medium-term goal for prostatectomy. Due to the relatively closed structure of the procedure, its standard-of-care robotic/laparoscopic solutions, and procedure economics, prostate procedures are an optimal early target for surgical automation. Prototyping and testing of possible solutions is done in constructed laboratory phantoms, either synthetic tissues or animal phantoms. To enable measurement of perceptual and robotic motion error, phantoms undergo volumetric imaging; these images are critical to both a potential deployed automatic system, used in planning motion and treatment (cutting, ablation, suturing, etc.), as well as post-hoc assessment of system performance. Rapid iteration on these phantom models yields small, inconsistent datasets, while the current workflow for human annotation is often anatomically unreliable and prohibitively time-consuming, rendering deep learning unsuitable at reasonable scales. To address these limitations, we present an automated 3D segmentation pipeline that uses classical medical image-processing techniques to encode the known anatomy of the phantoms as explicit geometric and intensity priors, which requires no training corpus and is transferred to each new phantom revision without re-annotation. Across 57 scans spanning multiple phantom revisions, our pipeline recovers the capsule interior at 0.83 median Dice on 11 contrast-suppressed scans and detects all 32 annotated focal lesions without false positives, completing a full scan in 2-8 minutes on commodity CPU hardware versus 1-2 hours by hand.

Figures & tables

Appendix figures & tables3 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Feb 19, 2026

Promptable segmentation with region exploration enables minimal-effort expert-level prostate cancer delineation

Purpose: Accurate segmentation of prostate cancer on magnetic resonance (MR) images is crucial for planning image-guided interventions such as targeted biopsies, cryoablation, and radiotherapy. However, subtle and variable tumour appearances, differences in imaging protocols, and limited expert availability make consistent interpretation difficult. While automated methods aim to address this, they rely on large expertly-annotated datasets that are often inconsistent, whereas manual delineation remains labour-intensive. This work aims to bridge the gap between automated and manual segmentation through a framework driven by user-provided point prompts, enabling accurate segmentation with minimal annotation effort. Methods: The framework combines reinforcement learning (RL) with a region-growing segmentation process guided by user prompts. Starting from an initial point prompt, region-growing generates a preliminary segmentation, which is iteratively refined through RL. At each step, the RL agent observes the image and current segmentation to predict a new point, from which region growing updates the mask. A reward, balancing segmentation accuracy and voxel-wise uncertainty, encourages exploration of ambiguous regions, allowing the agent to escape local optima and perform sample-specific optimisation. Despite requiring fully supervised training, the framework bridges manual and fully automated segmentation at inference by substantially reducing user effort while outperforming current fully automated methods. Results: The framework was evaluated on two public prostate MR datasets (PROMIS and PICAI, with 566 and 1090 cases). It outperformed the previous best automated methods by 9.9% and 8.9%, respectively, with performance comparable to manual radiologist segmentation, reducing annotation time tenfold.
Aug 14, 2026

Zero-Shot Adaptation of Medical Vision Foundation Models for High-Frequency Micro-Ultrasound Prostate Segmentation

Prostate cancer claims a life every 80 seconds. Early detection is needed to prevent disease progression, and both PSA density calculation and biopsy decisions rely on knowing the exact boundary of the gland. Conventional ultrasound at 6-12 MHz blurs this boundary, missing one in three high-risk cancers. Micro-ultrasound (29 MHz) improves resolution threefold but introduces dense acoustic speckle that obscures the outer wall; given the same image, two clinicians draw outlines differing by over 10% in area. Supervised methods are costly and generalise poorly across scanners. Can a foundation model segment the prostate with no training data? We present the first zero-shot pipeline for this modality: MedSAM, pre-trained on over 1.5 million medical images, localises the prostate; we then apply CLAHE to sharpen the outer wall, binary dilation to recover missed pixels, and Fourier smoothing (4 modes, s=1.05) to refine the boundary. MedSAM requires a spatial prompt, so we evaluate bounding-box and point-click strategies across 75 patients of the Micro-Ultrasound Prostate Segmentation dataset (2,621 slices). On the 20-patient held-out test set, the pipeline reduces mean boundary-distance error by 45% (Dice 0.749+/-0.043 to 0.865+/-0.029; HD95 217.2+/-36.9 to 120.1+/-26.1 px), reaching Dice 0.859 across the cohort. Its mean overlap shows no significant difference from the three non-expert rater groups (p>0.19), while segmenting 38-52% more consistently (lower inter-patient standard deviation). Point-click prompts fail regardless of placement (best Dice=0.350), because speckle gives no stable local contrast. Only an approximate bounding box is required, so any clinic can deploy it without data collection, annotation, or retraining.
Aug 20, 2026

Learning Prostate Anatomy at Test Time for Cancer Detection in Micro-Ultrasound

Domain shift across clinical centers using different imaging hardware or acquisition protocols remains a fundamental barrier to deploying deep learning models for prostate cancer (PCa) detection. Existing test-time adaptation (TTA) methods address distribution shift through entropy minimization or augmentation-based self-supervision, correcting for statistical differences in image appearance but ignoring the anatomical structure of the target domain. We propose ANT, a segmentation-guided TTA framework that adapts a pretrained cancer detection encoder to the target domain by solving an auxiliary prostate segmentation task at test time, supervised by pseudo-masks from a frozen pretrained segmentation network. By aligning encoder representations to prostate anatomy in the target domain, ANT corrects domain-specific feature drift while preserving cancer-discriminative structure. The model was trained on 693 patients imaged with an earlier-generation micro-ultrasound scanner in a multi-center clinical trial, and evaluated on 118 patients acquired with a newer-generation system across two centers in another clinical trial. Under a leave-one-center-out protocol with identical evaluation conditions across all methods, ANT improves mean AUC by 2.9% and 3.6% at the biopsy-core and patient levels, respectively, over no adaptation, outperforming TTA baselines. Code is available at: https://github.com/ObedDzik/ant.git.