cs.LGNov 6, 2026

A Clinical Evaluation of Conformal Prediction for Chest Radiograph Report Generation

Authors: Nikolaos Kontogeorgis, Pascal Krezer, Klaus-Rudolf Kladny, Arne Estler, Christian F. Baumgartner, Lisa Koch, Saif Afat, Michael Muehlebach

Organizations: Max Planck Institute for Intelligent Systems, Tübingen, Germany · University Hospital Tübingen, Tübingen, Germany · University of Lucerne, Lucerne, Switzerland · University of Bern, Bern, Switzerland · 

Abstract

While multimodal large language models (MLLMs) have improved automated radiology report generation, they remain prone to hallucinations, necessitating clinically meaningful risk-control methods. Conformal prediction (CP) provides statistical guarantees, yet existing CP approaches rely on uncalibrated automated extractors and fail to account for the clinical relevance of errors. We introduce clinical admissibility criteria (CLARITY), a framework for evaluating radiology reports that explicitly distinguishes clinically consequential errors from minor deviations. To eliminate reliance on automatic judges, we collected radiologist annotations of MLLM-generated reports using CLARITY. By benchmarking CP strategies and automatic evaluation metrics against these expert annotations, we demonstrate that commonly used admissibility proxies systematically fail to detect clinically relevant errors. Our findings reveal that automated admissibility judgments are largely decoupled from true clinical admissibility.

Figures & tables

Explore similar work

Mar 31, 2026

Calibrated Confidence Expression for Radiology Report Generation

Safe deployment of Large Vision-Language Models (LVLMs) in radiology report generation requires not only accurate predictions but also clinically interpretable indicators of when outputs should be thoroughly reviewed, enabling selective radiologist verification and reducing the risk of hallucinated findings influencing clinical decisions. One intuitive approach to this is verbalized confidence, where the model explicitly states its certainty. However, current state-of-the-art language models are often overconfident, and research on calibration in multimodal settings such as radiology report generation is limited. To address this gap, we introduce ConRad (Confidence Calibration for Radiology Reports), a reinforcement learning framework for fine-tuning medical LVLMs to produce calibrated verbalized confidence estimates alongside radiology reports. We study two settings: a single report-level confidence score and a sentence-level variant assigning a confidence to each claim. Both are trained using the GRPO algorithm with reward functions based on the logarithmic scoring rule, which incentivizes truthful self-assessment by penalizing miscalibration and guarantees optimal calibration under reward maximization. Experimentally, ConRad substantially improves calibration and outperforms competing methods. In a clinical evaluation we show that ConRad's report level scores are well aligned with clinicians' judgment. By highlighting full reports or low-confidence statements for targeted review, ConRad can support safer clinical integration of AI-assistance for report generation.
May 28, 2026

CCS: Clinical Consensus Selection for Radiology Report Generation

Radiology report generation (RRG) is commonly formulated as a single-path generation task, where a multimodal large language model (MLLM) produces one decoded report as the final output. While recent progress has largely been driven by scaling training data, model capacity, and retrieval mechanisms, improving report quality at inference time remains underexplored. In this work, we observe that fixed radiology MLLMs often generate clinically stronger reports elsewhere in their candidate pool than the one selected by default decoding, suggesting that inference-time decision making remains an overlooked bottleneck. To address this, we propose Clinical Consensus Selection (CCS), a decoder-agnostic inference-time selection framework that samples multiple candidate reports and selects the one with the highest clinical consensus across the rollout pool. CCS unifies text-based utilities with a radiology-adapted utility computed by an image--report-trained multimodal embedder, which measures candidate agreement beyond surface-level textual similarity. Across three datasets and multiple radiology MLLMs, CCS consistently improves inference-time performance over single-path decoding and generic Best-of-N baselines, with particularly clear gains on clinical metrics. Further analysis shows that image-grounded utility forms a selection axis distinct from textual consensus and that substantial headroom remains for improving RRG at inference time.
Mar 6, 2026

CRIMSON: A Clinically-Grounded LLM-Based Metric for Generative Radiology Report Evaluation

We introduce CRIMSON, a clinically grounded evaluation framework for chest X-ray report generation that assesses reports based on diagnostic correctness, contextual relevance, and patient safety. Unlike prior metrics, CRIMSON incorporates full clinical context, including patient age, indication, and guideline-based decision rules, and prevents normal or clinically insignificant findings from exerting disproportionate influence on the overall score. The framework categorizes errors into a comprehensive taxonomy covering false findings, missing findings, and eight attribute-level errors (e.g., location, severity, measurement, and diagnostic overinterpretation). Each finding is assigned a clinical significance level (urgent, actionable non-urgent, non-actionable, or expected/benign), based on a guideline developed in collaboration with attending cardiothoracic radiologists, enabling severity-aware weighting that prioritizes clinically consequential mistakes over benign discrepancies. CRIMSON is validated through strong alignment with clinically significant error counts annotated by six board-certified radiologists in ReXVal (Kendalls tau = 0.61-0.71; Pearsons r = 0.71-0.84), and through two additional benchmarks that we introduce. In RadJudge, a targeted suite of clinically challenging pass-fail scenarios, CRIMSON shows consistent agreement with expert judgment. In RadPref, a larger radiologist preference benchmark of over 100 pairwise cases with structured error categorization, severity modeling, and 1-5 overall quality ratings from three cardiothoracic radiologists, CRIMSON achieves the strongest alignment with radiologist preferences. We release the metric, the evaluation benchmarks, RadJudge and RadPref, and a fine-tuned MedGemma model to enable reproducible evaluation of report generation, all available at https://github.com/rajpurkarlab/CRIMSON.