We propose the radiometric camera, a model that lifts any central geometric camera model to a radiometric one. The lifted model keeps the projection of the geometric model and adds a finite aperture, a free-form focus surface and a generic vignetting function. We calibrate it by inverse rendering directly on the relative irradiance of the sensor, from the same images of standard calibration targets used in geometric calibration. Geometric calibration absorbs the bias of its feature detections. The proposed radiometric calibration uses no features, and our radiometric cameras have lower reprojection errors on held-out test sets. The focus surface extends defocus modeling from the thin lens to any central camera, and we use it in a first multi-view radiometric reconstruction, which recovers the in-focus reflectance of a texture from defocused images. The vignetting is estimated jointly and accurately reproduces a flat field measured through a diffuser. Because every standard camera model lifts to a radiometric one, the radiometric camera naturally and directly extends generative scene models beyond multi-view geometry to multi-view radiometric ones, where phenomena such as lighting and attenuation can be accurately estimated.
Figures & tables
Figure 1: Our radiometric camera model can be applied in downstream tasks like vignetting correction in panorama stitching or texture learning in inverse rendering.
Proj.
Apert.
Focus
Vign.
Calib.
Thin lens [ 54 ] , Mitsuba [ 35 ]
(✓)
✓
(✓)
(✓)
–
Lens-design ray tracing [ 41 ]
(✓)
✓
(✓)
(✓)
–
Tang and Kutulakos [ 67 ]
(✓)
✓
(✓)
(✓)
–
Kang and Weiss [ 37 ]
(✓)
–
–
(✓)
(✓)
Kim and Pollefeys [ 39 ]
–
–
–
✓
(✓)
Neural lens model [ 76 ]
✓
–
–
✓
(✓)
Table 1: Prior camera models (top) and calibration methods (middle) against the radiometric camera: any central projection, a finite aperture, a free-form focus surface, a generic vignetting function, and the joint calibration of all of them from images. ✓: general; (✓): restricted, e.g . to the perspective projection, a plane of focus, the cos4 falloff or a subset of the parameters; –: not modeled. Section 2 gives the details.
Figure 2: The radiometric camera lifts any central geometric model, here a perspective and a fisheye model, in a cross-section. The geometric model alone sets the direction d^(p) in which the ray of the sensor point p leaves the center o of the aperture A ; the model does not trace the light inside the camera (dashed). The lift adds the aperture: the rays through all aperture points a meet in the point of focus xf(p) on the focus surface F , which is close to a plane for the perspective model and surrounds the camera for the fisheye. Where the scene is off F , the cone of these rays meets it in a region (thick blue), from which p collects its light.
Figure 3: Fixed samples (dots) miss a boundary that moves with a parameter (solid black to dashed red): none lies in the region that it sweeps, so the sampled gradient lacks its contribution (left). We remove both boundaries of the calibration (right). Top: the samples of the aperture are placed from the fixed unit disc D and move with its radius r . Bottom: the blur of the print makes the albedo ρ smooth across an edge of the pattern. Hollow dots: after the change.
Figure 4: The bias of a detector (column 2) is absorbed by a geometrically calibrated camera (columns 3 and 4). With the calibrated poses, the bias is pushed into the camera model (column 3); with the true poses (column 4), it shows that the poses compensate for part of it. Our radiometric refinement does not rely on a detector and removes most of the bias in both evaluations.
Tamron 20 mm
Sigma 14 mm
Sigma 8 mm fisheye
Model
AprilGrid
Siemens stars
AprilGrid
Siemens stars
AprilGrid
Siemens stars
Median reprojection error [px]
Brown–Conrady
0.119 → 0.067
0.288 → 0.135
0.499 → 0.377
0.687 → 0.359
–
–
OpenCV-14
0.107 → 0.060
0.308 → 0.131
0.476 → 0.359
0.600 → 0.384
1.98 → 1.70
0.123 → 0.079
Kannala–Brandt
0.117 → 0.106
0.183 → 0.176
0.456 → 0.351
0.567 → 0.329
2.00 → 1.52
0.113 → 0.063
Double Sphere
0.261 → 0.286
0.219 → 0.268
1.42 → 1.34
0.734 → 0.461
2.09 → 1.49
0.109 → 0.067
Table 2: Reprojection error on the held-out high-precision target, geometric start → radiometric refinement, for each camera model, lens and calibration target. The refined value is bold where it is significantly lower than the start and italic where it is significantly higher (95 % bootstrap interval of the difference, Tab. A4 ); the mean and the RMS are in Tab. A5 . –: Brown–Conrady cannot represent the 180∘ field of view of the fisheye.
Figure 5: Median reprojection error during the radiometric refinement of the central spline on the Sigma 14 mm, with respect to the detections that the geometric calibration was fitted to and on the held-out high-precision target. After the first iterations the curves diverge in both panels: the error on the detections rises while the error on the held-out target falls, which shows that the geometric calibration had absorbed the bias of its detector.
Figure 6: Normalized vignetting along the direction of the sensor diagonal through the principal point: the cos4 falloff of the thin lens and our learned vignetting against the measured flat field.
Figure 7: The focus model. Left: the learned focus surfaces, a hemisphere for the fisheye at f/4 and a plane for the Tamron 20 mm at f/8 . Right: a texture estimated from defocused images. The radiometric camera recovers sharp text, whereas the pinhole camera has to put the blur of the images into the texture.
Refinement
Median [px]
95th perc. [px]
Tamron 20 mm, f/8 , central spline
Geometric start
0.160
0.499
Pinhole
0.199
0.534
Aperture and focus
0.149
0.410
− pinhole
−0.051 [ −0.054 , −0.047 ]
−0.124 [ −0.139 , −0.103 ]
Zoom at 48 mm, f/10 , Brown–Conrady
Table 3: Defocus ablation on the held-out target: the refinement as a pinhole and with the aperture and the focus surface, and their difference with its 95 % bootstrap interval. Bold and italic as in Tab. 2 .
Figure A1 : The two calibration boards (rows) as the calibration of each of three lenses reconstructs them, from the photographs of one session. Surfaces: every point of the planar board moved by the offset learned for it in the calibration with that lens, in the plane by the print error (aspect and skew) and along the normal by the height; the offsets are drawn 50 times enlarged, the colour is the height in bands of 0.5 mm, and the dots are the 5×5 nodes of the height field. Maps: the length of the difference between the offsets learned with the two lenses (in the plane and along the normal together) at every point of the page. Under each map: the RMS and the largest value of that length in mm. In each row the three surfaces come first and the three maps follow, one for each pair of lenses (Sigma 14 mm minus Tamron 20 mm, fisheye minus Tamron 20 mm, Sigma 14 mm minus fisheye).
Lens
Type
Geom.
Vign.
Defocus
Tamron 20 mm F/2.8 Di III
wide angle
✓
✓
✓
Sigma 14 mm F2.8 EX HSM
rectilinear
✓
✓
✓
Sigma 8 mm F3.5 EX DG
circular fisheye
✓
✓
✓
24–70 mm zoom at 48 mm
normal
✓
Table A1 : The lenses of the data set and the experiments they take part in: geometric accuracy ( Sec. 5.2 ), vignetting ( Sec. 5.3 ) and defocus ( Sec. 5.4 ). The camera is a Sony ILME-FX3 throughout.
lens
target
role
distance [mm]
f/
exposure
captured
used
Geometric accuracy ( Sec. 5.2 )
Sigma 14 mm
Siemens stars
train
295
22
1.6 s
168
132
Sigma 14 mm
AprilGrid
train
–
22
2 s
408
399
Sigma 14 mm
Thorlabs
test
300
22
1/10 s
142
141
Sigma 8 mm fisheye
AprilGrid
train
186
22
2 s
407
249
Sigma 8 mm fisheye
Thorlabs
test
121
22
1/13 s
154
154
Table A2: The captures of the data set, grouped by experiment, each training set followed by the test set captured with it. Role is the training/test split: training images calibrate the camera, test images (Thorlabs) only score it. Captured : the images of the set; used : those that enter the experiment, i.e . for a training set the images in which the geometric pipeline that starts our refinement localizes the board, and for a test set those whose dots are registered. The used counts are those of the starts before the geometric image changed to the full-resolution green image ( Sec. A.14.2 ) and are to be regenerated. Distance: the median camera-to-target-plane distance inferred from the estimated poses (–: not yet computed). Of the 106 images of the text board, 63 fit the texture, 22 choose its regularization and 21 test it. Flat field : one image per lens through a diffuser (a white acrylic plate over the lens, hood on, lit by diffuse daylight), captured in the same session as the lens’s vignetting set (2026-10-28); it is the reference the learned vignetting is compared with, not used in any calibration. The fisheye Siemens-star set of 2026-10-27 (150 images, 118 Thorlabs) is excluded: the start pipeline localized too few of its images.
Figure A2 : The Thorlabs R3L3S7N1 target on its LED backlight, from our capture.
grid
17×17 dots, 80×80mm
dot spacing
5.000mm
dot diameter
0.500mm
tolerance ∗
±5μm
substrate
soda-lime glass, 90×90mm
coating
OD 3 chrome, 0.12μm
polarity
clear dots, opaque field
Table A3: Specifications of the Thorlabs R3L3S7N1 target (manufacturer’s drawing, 15 Nov 2024). ∗ Of the dot diameter, the dot spacing and the corner-to-corner distance.
Table A6 : Runtime of one radiometric calibration: the refinement of the central spline of the Sigma 14 mm lens on the Siemens-star set, from its loaded geometric start to the written calibrated camera, over 8 runs, each on its own GPU after an untimed warm-up run. The decoding of the photographs and the geometric start are not included.
Median [px]
95th percentile [px]
Model
Geom.
Radiom.
Δ [95 % interval]
Geom.
Radiom.
Δ [95 % interval]
Tamron 20 mm, AprilGrid (142 test images, 40,999 dots)
Brown–Conrady
0.119
0.067
−0.052 [ −0.062 , −0.043 ]
0.356
0.173
−0.183 [ −0.208 , −0.161 ]
OpenCV-14
0.107
0.060
−0.048 [ −0.059 , −0.037 ]
0.373
0.155
−0.217 [ −0.270 , −0.180 ]
Kannala–Brandt
0.117
0.106
−0.011 [ −0.020 , −0.001 ]
0.446
0.285
−0.162 [ −0.220 , −0.102 ]
Double Sphere
0.261
0.286
+0.025 [ +0.000 , +0.046 ]
1.70
1.16
−0.545 [ −0.773 , −0.294 ]
Table A4 : Median and 95 th percentile of the reprojection error on the held-out target at the geometric start and after the radiometric refinement, with their difference Δ and its 95 % bootstrap interval. Bold: significantly lower than the start; italic: significantly higher.
Mean [px]
RMS [px]
Model
Geom.
Radiom.
Δ [95 % interval]
Geom.
Radiom.
Δ [95 % interval]
Tamron 20 mm, AprilGrid (142 test images, 40,999 dots)
Brown–Conrady
0.147
0.077
−0.069 [ −0.080 , −0.059 ]
0.185
0.092
−0.093 [ −0.110 , −0.081 ]
OpenCV-14
0.144
0.070
−0.075 [ −0.090 , −0.063 ]
0.201
0.083
−0.118 [ −0.145 , −0.098 ]
Kannala–Brandt
0.159
0.124
−0.034 [ −0.052 , −0.020 ]
0.214
0.149
−0.065 [ −0.092 , −0.043 ]
Double Sphere
0.473
0.429
−0.044 [ −0.085 , −0.007 ]
0.875
0.696
−0.179 [ −0.228 , −0.128 ]
Table A5 : Mean and RMS of the reprojection error, as Tab. A4 .
Figure A3 : Stitched panoramas showing the improvement after our vignetting correction for the Sigma 14mm lens at f/4 , fisheye lens at f/4 and Tamron 20mm lens at f/2.8 . All panels are drawn with the same display curve (gain 2.5 , gamma 1.5 ).
Radiance fields, implemented with either implicit (NeRF) or explicit (Gaussian Splatting) representations, are advancing the state of the art in novel view synthesis at a rapid pace. Even though the rendered views they generate are often compelling, they are not free of errors. In this paper, we propose a new approach for pixel-wise uncertainty quantification based on measuring the inconsistencies among renderings by the radiance field model in virtual cameras sampled near the target viewpoint. We named our approach VCURF for Virtual Camera-based Uncertainty of Radiance Fields. VCURF treats the radiance field model as a black box, only assuming that it is capable of rendering color and depth on demand. This property makes our approach applicable to both NeRF and GS models without any modification. Our experiments on a combination of datasets, radiance field models and baselines demonstrate VCURF's effectiveness in pixel-wise uncertainty estimation. We conclude the paper with findings that question the way view selection is tackled by the majority of the current literature.
Recovering dense 3D geometry from unposed images remains a foundational challenge in computer vision. Current state-of-the-art models are predominantly trained on perspective datasets, which implicitly constrains them to a standard pinhole camera geometry. As a result, these models suffer from significant geometric degradation when applied to wide-angle imagery captured via non-rectilinear optics, such as fisheye or panoramic sensors. To address this, we present CAM3R, a Camera-Agnostic, feed-forward Model for 3D Reconstruction capable of processing images from wide-angle camera models without prior calibration. Our framework consists of a two-view network which is bifurcated into a Ray Module (RM) to estimate per-pixel ray directions and a Cross-view Module (CVM) to infer radial distance with confidence maps, pointmaps, and relative poses. To unify these pairwise predictions into a consistent 3D scene, we introduce a Ray-Aware Global Alignment framework for pose refinement and scale optimization while strictly preserving the predicted local geometry. Extensive experiments on various camera model datasets, including panorama, fisheye and pinhole imagery, demonstrate that CAM3R establishes a new state-of-the-art in pose estimation and reconstruction.
Namitha Guruprasad, Abhay Yadav, Cheng Peng +1
Johns Hopkins University, Baltimore, MD 21218, USA · University of Virginia, Charlottesville, VA 22904, USA
In 3D reconstruction, camera calibration is an essential element for achieving high fidelity and accuracy of the reconstructed geometry. While existing approaches rely upon 2D planar calibration, this work proposes a framework tailored for 3D reconstruction that is based on predicting scene rays, which adds flexibility to the reconstruction pipeline and enables the use of recent advances in camera models. Novel metrics, reconstruction and intersection error, derived from predicted scene rays are employed in combination with a bootstrapping procedure that statistically evaluates different calibration objects and calibration pipelines for both intrinsic and extrinsic camera parameters. The results show that the generalized distortion model more faithfully captures physical camera effects and yields an improvement in calibration accuracy. Reprojection error is shown to be a potentially misleading indicator of 3D accuracy, and the proposed ray-based metrics provide a more holistic assessment. An icosahedron calibration target is designed to enrich calibration information for 3D reconstruction together with a ring-feature-based detector. The icosahedral target yields approximately 40% lower mean intersection and more stable calibration across bootstrap trials on synthetic data, while real-data performance demands very tight fabrication tolerances.
Dennis Ruppel, Hasan Kutlu, Kai A. Neumann +4
Fraunhofer Institute for Computer Graphics Research, Darmstadt · Computer Vision, Imaging and Data Analysis Group, Technical University of Applied Sciences Würzburg-Schweinfurt · Mathematical and Applied Visual Computing, Technical University Darmstadt