Scalable Evaluation of Medical AI using Evidence-based Practice Recommendations
Organizations: Google Research · NYU Grossman School of Medicine, NYU Langone Health
Abstract
Rigorously evaluating medical artificial intelligence (AI) requires testing open-ended clinical management across diverse presentations and stages of care. However, existing benchmarks rely on manual expert authoring, limiting coverage across conditions, conditional care pathways, and evolving guidelines. We develop an automated pipeline that extracts and verifies structured clinical criteria and branching decision trees from practice recommendations to generate scenarios spanning the care continuum, including nuanced presentations and practice variations across regions and guideline editions. Applied to 436 BMJ Best Practice clinical monographs (354 US, 82 International), this yields 3,200 scenarios spanning differential diagnosis, investigations, treatment, and complications, plus targeted suites for regional specificity (731 US/International pairs) and temporal freshness (630 scenarios). To grade responses, we develop a clinician-calibrated autorater that scores management plans on a 4-point rubric stratifying deviations by clinical severity. Across Gemini models, scaling improves adherence, while web search (+0.8 percentage points [pp] on average) and multi-sample synthesis (+2.2 pp) combine additively (+2.8 pp). In context, full monographs consistently trail condensed excerpts. On targeted suites, web search narrows international performance gaps (+4.2 pp) and improves adherence to newly updated guidance (+4.6 pp). In a study with Primary Care Physicians (n = 9) across 200 scenarios, AI assistance raises adherence from 50.5% to 70.0%, driven largely by fewer clinical omissions. Overall, our results demonstrate a scalable evaluation setup using an evidence-based corpus originally written to guide human clinical decision-making, and demonstrate its viability to assess medical AI and its assistance on clinician decision-making.
Figures & tables
| Score (1–4) | Category | Description |
|---|---|---|
| 4 | Adherent / Acceptable | Matches the evidence-based practice recommendation, or an alternative but clinically appropriate choice (e.g., equivalent drug from the same class). |
| 3 | Minor Deviation | Suboptimal but safe (e.g., omitting routine monitoring; ordering a test too early). |
| 2 | Moderate Deviation | Clinically significant omission or suboptimal choice without immediate risk of severe harm. |
| 1 | Major Deviation | Contraindicated treatment, unsafe dose, or missed life-threatening red flag. |
Appendix figures & tables18 assets
Supplementary material from the paper’s appendix.
Appendix
| Perturbation Dimension | Perturbation Construction | Rel. Length | Exact 4-Tier | Adjacent ( ) |
|---|---|---|---|---|
| Repeat Sampling | Independent re-evaluation of identical prompt and response | ( ) | ( ) | |
| Presentation Order | Swap Ground Truth and AI Response order in prompt | ( ) | ( ) | |
| Structural Order | Permute intra-response lists and reverse JSON key ordering | ( ) | ( ) | |
| Output Length (Shorter) | Concise telegraphic phrasing (stripped rationales) | ( ) | ( ) | |
| Output Length (Longer) | Verbose narrative prose framing around identical actions | ( ) | ( ) |
| Model | Inference Harness | Major Deviation (%) | Moderate Deviation (%) | Minor Deviation (%) | Adherent (%) |
|---|---|---|---|---|---|
| Gemini 3.1 Flash Lite | Baseline | 0.78 [0.54, 1.03] | 16.88 [15.76, 17.99] | 10.75 [10.00, 11.57] | 71.60 [70.24, 72.89] |
| With Search | 0.79 [0.55, 1.05] | 16.87 [15.78, 17.98] | 10.42 [9.66, 11.22] | 71.92 [70.59, 73.22] | |
| Synthesize-4 | 0.66 [0.44, 0.90] | 15.14 [14.05, 16.18] | 9.84 [9.03, 10.64] | 74.36 [73.02, 75.62] | |
| Search + Synth-4 | 0.69 [0.47, 0.94] | 15.53 [14.47, 16.59] | 9.25 [8.59, 10.04] | 74.54 [73.16, 75.75] | |
| Dynamic Guideline | 0.87 [0.64, 1.13] | 16.09 [15.01, 17.16] | 9.86 [9.09, 10.58] | 73.18 [71.89, 74.43] | |
| Dynamic Excerpt | 0.57 [0.38, 0.81] | 12.33 [11.40, 13.23] | 8.60 [7.88, 9.35] | 78.49 [77.34, 79.71] |
| Error Pattern | Oracle Excerpt | Oracle Guideline | Mechanism & Illustrative Examples |
|---|---|---|---|
| 1. Omitted First-Line Therapy or Primary Workup | Mechanism: The model identifies the right condition and care setting, but leaves out a required upfront medication or primary diagnostic test due to full-monograph dilution ( Oracle Guideline ) or missing cross-section context ( Oracle Excerpt ). Examples: For a hospitalized older adult developing acute severe hypernatremia with neurological changes and osmotic diuresis, the guideline specifies urgent brain MRI to evaluate for osmotic demyelination or intracranial hemorrhage. Given the focused Complications excerpt, the model orders urgent neuroimaging alongside controlled fluid correction, whereas given the full guideline (dominated by fluid-calculation branches) it manages the sodium deficit and hyperglycemia but omits the brain MRI. Conversely, in an Investigations scenario for Crohn’s disease with a draining perianal fistula, Oracle Excerpt orders every required scan and scope but misses first-line antibiotics (metronidazole or ciprofloxacin) listed only in the unprovided Treatment section, which Oracle Guideline includes. | ||
| 2. Conditional Deferral or Under-Triage | Mechanism: The model mentions the appropriate test, medication, or escalation step, but defers an immediate guideline requirement as a conditional fallback or manages an urgent case as a routine clinic visit. Examples: For a patient with lumbar S1 radiculopathy accompanied by objective plantar-flexion weakness ( ) and a diminished ankle reflex ( ) on exam (focal neurological deficits warranting upfront lumbar spine MRI), Oracle Excerpt orders the MRI upfront in most runs, whereas Oracle Guideline usually defers or declines immediate imaging by misapplying the uncomplicated -week low-back-pain rule. In rarer acute cases, when an outpatient with chronic methamphetamine use presents with new-onset focal seizures, severe untreated hypertension, and cognitive decline (suspected cerebral vasculitis), the model arranges outpatient neuroimaging and neurology follow-up instead of immediate Emergency Department transfer and inpatient admission. | ||
| 3. Misapplied Subgroup Criteria, Cutoffs, or Contraindications | Mechanism: Prominent cues in the patient story override an explicit laboratory threshold, timing criterion, or subgroup rule stated in the provided guideline. Examples: In a postpartum patient presenting hours after cesarean delivery with worsening thrombocytopenia, anemia, hemolysis, and petechiae, the guideline notes that progressive cytopenias beyond hours exclude uncomplicated HELLP syndrome and point to acute myeloid leukemia (AML). Anchoring on the postpartum obstetric framing, the model diagnoses persistent HELLP or thrombotic microangiopathy and omits AML from the differential diagnosis and diagnostic workup. Similarly, for suspected late Lyme arthralgia lasting longer than weeks—where the guideline restricts second-tier confirmatory immunoblot testing strictly to IgG Borrelia antibodies— Oracle Excerpt follows the timing rule whereas Oracle Guideline orders both IgM and IgG Western blots. | ||
| 4. Omitted Secondary Screening, Rule-Out, or Supportive Checks | Mechanism: The model follows all primary diagnostic, triage, and first-line treatment recommendations, but leaves out a secondary tumor screen, prophylaxis measure, or targeted supportive check listed in the guideline. Examples: In a young woman presenting with acute psychosis, fever, and suspected anti-NMDA receptor autoimmune encephalitis (mimicking neuroleptic malignant syndrome), the model outlines the complete neurodiagnostic, lumbar puncture, antibody, and ICU immunotherapy plan, but receives a Minor Deviation for omitting pelvic imaging (ultrasound or CT) to screen for an underlying ovarian teratoma. Similarly, in a -year-old woman with giant cell arteritis on tocilizumab and chronic high-dose prednisone ( ) presenting with drug-induced liver injury, plans appropriately hold tocilizumab and order hepatic workup, but omit guideline-indicated Pneumocystis jirovecii pneumonia prophylaxis. | ||
| Total Non-Adherent | Residual non-adherence ( ) in Table SI3 . |
Clinical Language Model Evaluation
Clinical language model evaluation measures whether AI systems are accurate, safe, fair, and useful across medical tasks and care settings.
See all 471 papers