Patient-level splitting is the standard safeguard against subject leakage in medical imaging evaluation, but it cannot remove a confounder that every fold inherits: an acquisition variable aligned with the diagnosis across the whole cohort. We present a five-question audit of a candidate confounder: how well it predicts the diagnosis, whether it can be decoded from the images, whether diagnostic scores depend on it, whether the image adds predictive value beyond it and how much discrimination survives once it is controlled. We apply it to DMR-IR, the public dataset on which most machine-learning results in breast thermography rest. On 236 patients under a strict patient-disjoint protocol, the acquisition date alone predicts malignancy at AUROC 0.980, above every imaging arm we evaluated (best 0.949), because benign and malignant patients were recruited in different years. The acquisition year is decodable from the pixels among patients who share a diagnosis, largely through a global thermal offset outside the breast, yet only one arm, the one pooling every frame of a visit, demonstrably carries it into its diagnostic score. No arm improves on the date on paired folds, and once the date is controlled, discrimination either collapses or survives only on comparisons the benchmark cannot attribute. The dataset contains only eight cross-label same-date pairs, from ten patients, which limits reliable evaluation within recorded acquisition-date groups. A second, independently acquired cohort, whose dominant channel is patient age, reproduces every finding except legibility, from a confounder that is clinically legitimate. Mitigation may suppress such a confounder, but without cross-label acquisition support no evaluation on the benchmark can certify that what remains is pathology.

Figures & tables

Appendix figures & tables16 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 30, 2026

Scores That Hold, Benchmarks That Leak: Measuring Dataset Contamination in Public Brain-Tumor MRI Classification

Automated classification of brain tumors from MRI is a heavily published application of deep learning in medical imaging, with reported accuracies on public benchmarks routinely exceeding 98%. However, accuracy does not capture a critical dimension of benchmark quality: dataset integrity, defined as the independence of test from training data at the image, patient, and acquisition-source levels. We introduce a three-layer contamination framework comprising duplicate, patient, and source-label leakage to assess the public corpora on which this literature rests. We audit the three most widely used corpora against a chest-radiograph negative control and quantify each layer's effect on measured performance across nine architectures and three evaluation conditions. Contamination is severe at every layer: 28.8% of the dominant corpus's official test split has a near-twin in its own training split, a second corpus leaks 22.3% of its test images byte-identically, 95.5% of traceable test images share a patient with training, and file-header features containing no anatomy separate tumor from no-tumor at 0.959 balanced accuracy, at parity with fine-tuned ResNet backbones. The unexpected result is that removing every identified leaked test image leaves balanced accuracy essentially unchanged: stable performance after deduplication does not establish benchmark integrity. Our findings establish dataset integrity as a distinct, measurable axis of benchmark quality that a stable leaderboard cannot certify. For biomedical research, reported accuracy on these corpora alone does not establish that a model has learned to recognize tumors rather than exploit dataset-specific cues. We release the contaminated-file lists, recovered patient identifiers, and deduplicated splits.
Nov 20, 2026

Duplicate- and Patient-Overlap Leakage in Brain MRI Tumor Classification: A Multi-Model Evaluation

Background. Repeated MRI images and distinct slices from the same patient can both compromise evaluation of brain tumor classifiers. Objective. We audited image duplication and examined how patient overlap relates to discrimination, probability error and model ranking. Methods. The Cheng/Figshare dataset contains 3,064 contrast-enhanced T1 MRI slices, three tumor classes and 233 recorded patient IDs. The dataset author advised treating the IDs as individuals, but original DICOM records were unavailable for verification. Four CNN architectures were trained under image-level and recorded-ID-disjoint protocols with five folds matched on size and class counts (40 original runs). A patient-cluster bootstrap quantified uncertainty. The extension added 60 split-seed runs, 40 training-seed runs and 72 fixed-test sibling-exposure runs with class-matched other-patient controls. Results. We found no exact duplicate images and little evidence of cross-patient near-duplicates among screened pairs. Image-level minus recorded-ID-disjoint balanced accuracy ranged from +0.0318 to +0.0462 across models. Expected calibration error and multiclass Brier scores were lower on the image-level evaluation sample. The balanced-accuracy difference persisted across new seeds for ResNet50 and DenseNet121, but their original ranking reversal did not replicate. Only ResNet50 in fold 2 passed Holm correction in the five-test exposure family. All 16 correlated exploratory subgroup estimates were positive, with no consistent dose-response. Conclusions. Patient overlap was associated with higher apparent performance on this benchmark. Fixed-test comparisons could not isolate patient identity from shared anatomy or acquisition characteristics. No independent external clinical validation was performed.
Nov 5, 2026

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

Benchmarks of class-imbalance strategies for multimodal chest X-ray (CXR) and electronic health record (EHR) prediction are often evaluated on record-level splits of cohorts in which one patient contributes several radiographs. We audit such a benchmark on 29,083 MIMIC-CXR radiographs of 10,479 patients with eight diagnosis targets. First, the record-split benchmark was misleading: a lookup table that copies the label of a development-set radiograph with the same EHR vector nearly matched the best model, and on unseen patients every model fell to the level of predicting every case positive. Second, tracing the labels back to MIMIC-IV explained why: each patient's labels are keyword matches on the diagnosis codes of a single admission, copied, with one EHR vector per patient, to all of the patient's radiographs, so about a third of the radiographs carry labels that differ from the codes of their own admission. Third, under patient-separated evaluation with admission-aligned and rule-refined labels, the initial conclusions do not hold: in the evaluated configurations no imbalance strategy raised the observed mean macro F2 over no augmentation by more than 0.01, tuned tree ensembles showed no consistent advantage over tuned logistic regression, and the released EHR variables stayed at the level of the all-positive baseline, whereas the diagnostic history available at imaging time and image embeddings exceeded it, including, with rule-refined labels, a CheXpert-trained encoder that never saw these radiographs; RAD-DINO had seen 96.6% of them during self-supervised pretraining. Adding either encoder to the diagnostic history gave no statistically significant F2 gain; exploratory AUROC gains were significant with RAD-DINO but not with DenseNet. We provide reusable diagnostics, a leakage-aware protocol and a checklist.