LesionAgent: Training-Free Agentic Tumor Tracking and Response Assessment in Longitudinal CT
Authors: Maximilian Rokuss, Jeya Maria Jose Valanarasu, Alejandro Lozano, Benjamin Hamm, Yannick Kirchhoff, Fabian Isensee, Klaus Maier-Hein
Organizations: Division of Medical Image Computing, German Cancer Research Center (DKFZ), Heidelberg, Germany · Faculty of Mathematics and Computer Science, Heidelberg University, Germany · Microsoft Research · Stanford University · Medical Faculty, Heidelberg University, Germany · HIDSS4Health, Heidelberg · National Center for Tumor Diseases (NCT) Heidelberg, Germany · Pattern Analysis and Learning Group, Department of Radiation Oncology, Heidelberg University Hospital, Germany
Every few months, a cancer patient's CT scans decide whether treatment continues. 3D foundation models can now detect, segment, register and track lesions, yet none of them reads the scans as a radiologist does. A radiologist decides which findings are lesions, which are the same lesion months later and whether a new spot means progression, and checks each decision against the extensive rules of a clinical guideline. We introduce LesionAgent, an LLM agent that performs this read end to end without task-specific training. It operates frozen 3D models as tools, acts in 3D through coordinate-labelled views, remembers every lesion across visits in a registry, verifies every model output it relies on, and leaves every number to a deterministic guideline engine. On four public longitudinal CT datasets, LesionAgent tracks more lesions and measures them more accurately than every automatic baseline, and where the same 3D models chained by fixed rules call progression falsely at 33 of 56 follow-ups, it does so twice. On clinical follow-up CTs, it agrees with the radiologists' response at 20 of 23 follow-ups, including every change in response, and without training on DeepLesion, it retrieves more of its lesions than every tracker trained on it (89.0% vs. 87.4%). Its harness, not its LLM, makes the difference: given the same LLM and 3D models but not the harness, Claude Code reaches a detection F1 of 41% and LesionAgent 78%, and an open-weight LLM that can run inside the hospital rises from 6% to 73%. LesionAgent and a napari reading app for any LLM are available at https://github.com/MIC-DKFZ/LesionAgent.
Figures & tables
Figure 2: LesionAgent. An LLM calls frozen 3D foundation models as tools (top). It checks their outputs in coordinate-labelled views, keeps every lesion at every visit in a registry (BL = baseline, FU = follow-up) and verifies masks with a second opinion. A deterministic guideline engine measures the lesions, assigns the response and writes the RECIST report. Optionally, a clinician answers the LLM’s questions (dashed). The bottom row shows the five steps of a read on real CT crops, from detecting all lesions to assessing the response.
Table 1: The 18 tools , the agent’s only means of action.
HCUCH [ 48 ]
TumorMap [ 28 ]
PanTrack [ 30 ]
NCI-MATCH [ 12 ]
Method
F1
Track
LD ↓
Resp.
F1
Track
LD ↓
Resp.
Rec.
Track
LD ↓
Rec.
Track
LD ↓
Models
LesionLocator [ 49 ]
–
98 ± 2
2.8 ± 0.4
75 ± 15
–
74 ± 4
7.3 ± 1.3
29 ± 9
–
94 ± 3
3.3 ± 1.0
–
81 ± 7
4.0 ± 1.2
LongiTrack [ 30 ]
–
98 ± 2
3.0 ± 0.6
91 ± 5
–
73 ± 4
7.9 ± 1.6
29 ± 6
–
92 ± 3
3.0 ± 0.4
–
74 ± 8
3.9 ± 1.0
Reg. → ULS [ 10 ]
–
98 ± 2
3.9 ± 0.5
95 ± 4
–
85 ± 3
7.9 ± 2.4
62 ± 10
–
83 ± 5
3.8 ± 0.9
–
84 ± 6
5.5 ± 1.9
Interactive
Agentic
LesionAgent (Opus 5.5)
–
100 ± 0
1.6 ± 0.4
95 ± 4
–
91 ± 3
4.5 ± 0.8
69 ± 9
–
97 ± 2
2.6 ± 0.3
–
97 ± 3
3.3 ± 1.2
Pipeline
VoxTell → LongiTrack
62 ± 2
86 ± 5
4.5 ± 0.8
40 ± 13
52 ± 3
54 ± 5
8.1 ± 1.9
37 ± 7
93 ± 6
84 ± 6
12.7 ± 3.4
52 ± 9
39 ± 8
4.8 ± 3.1
Table 2: End-to-end lesion tracking and response assessment. Interactive methods get one click per baseline lesion, automatic methods only the images. Without task-specific training, LesionAgent is best or on par on every metric in both settings, and with only open-weight models it is still the best open method on most metrics. Metrics are in % except LD (mm), Resp. is a balanced accuracy and ± the bootstrap standard deviation. Bold marks the best per setting, underlined the best open-weight automatic method.
Figure 3: LesionAgent next to human readers in detection, measurement and response assessment. (a–c) On LIDC, LesionAgent reads 436 screening CTs as a fifth radiologist, scored like each of the four readers against the nodules marked by at least two of the others. It finds fewer nodules, above all small ones (a), but its findings are more often real (b) and it measures them as accurately as the radiologists (c). Shading marks the nodules measurable under RECIST ( ≥ 10 mm). (d) On the 23 HCUCH follow-ups, its response matches the clinical reference 20 times, missing no response and no progression.
Figure 4: What LesionAgent catches. One real case per step of a read, from our test data: the tools’ outputs, the agent’s reasoning (shortened from the run log) and the prompts it gives nnInteractive. (1) The agent keeps the lesions VoxTell finds and, reading the scan itself, adds a nodule that no detector proposed. (2) A second opinion exposes a mask that includes a vessel. (3) LongiTrack follows another structure at the registered point, and the agent looks at the slices around it. (4) A small new spot counts as a new lesion only once it has grown, and the guideline engine derives the response. Every result agrees with the expert.
Table 6
Appendix figures & tables9 assets
Supplementary material from the paper’s appendix.
Appendix
Method
Venue
3D
Several scans
Find lesions
Measure
Track
Correct errors
New lesions
Response
Agent
Code
Here
3D foundation models
VoxTell [ 50 ]
CVPR’26
✓
–
✓
✓
–
–
–
–
–
✓
T, B
nnInteractive [ 23 ]
arXiv’25
✓
–
–
✓
–
–
–
–
–
✓
T
ULS23 [ 10 ]
MedIA’25
✓
–
–
✓
–
–
–
–
–
✓
B
uniGradICON [ 63 ]
MICCAI’24
✓
✓
–
–
∘
–
–
–
–
✓
T, B
TotalSegmentator [ 67 ]
Radiol. AI’23
✓
–
∘
∘
–
–
–
–
–
✓
T
Lesion trackers
DLT [ 4 ]
CVPR’21
✓
✓
–
–
✓
–
–
–
–
–
B †
Appendix
Table S1 : What related methods cover of tumor monitoring. Each prior method solves part of the read, and only LesionAgent covers every step. A ✓ marks a step the method does itself and ∘ a step it does in part, e.g . only for target lesions, only in 2D or with code but no weights. Find means locating lesions without being told where they are, and Correct detecting and correcting wrong model outputs. The last column gives how we use each method: as a tool of LesionAgent (T), as a baseline (B, † numbers from its paper) or by the same recipe with public models (R).
HCUCH
TumorMap
LesionAgent vs.
F1
Track
LD
Resp.
F1
Track
Resp.
Pipeline
+16 [5, 24]
+2 [ − 11, 18]
− 2.6 [ − 5.3, − 0.5]
+54 [25, 86]
+10 [4, 16]
+21 [13, 33]
+42 [22, 57]
Claude Code
+47 [4, 68]
+25 [9, 43]
− 0.4 [ − 2.0, 1.6]
+15 [ − 8, 23]
+13 [ − 12, 28]
+38 [15, 49]
+5 [ − 11, 23]
Qwen3.8 agent
+5 [ − 7, 16]
+6 [0, 21]
− 2.4 [ − 7.9, − 0.4]
+33 [11, 77]
+12 [6, 20]
+18 [9, 32]
+27 [6, 49]
Opus one-shot
+57 [17, 74]
+35 [16, 53]
− 4.3 [ − 12.9, − 1.6]
+7 [ − 2, 24]
+23 [ − 5, 39]
+48 [28, 56]
+10 [ − 10, 32]
Appendix
Table S2 : LesionAgent’s gains hold at the patient level. LesionAgent − baseline (in points, LD in mm, negative is better) with 95% CI from 4000 paired bootstrap resamples of the patients (HCUCH: series). Shaded and bold: the CI excludes zero. LesionAgent tracks lesions significantly better than Claude Code and Opus one-shot on both datasets and assesses the response significantly better than the pipeline and the open-weight agent. On HCUCH, it also finds and measures lesions significantly better than Opus one-shot.
Figure S1 : The agent’s judgement removes false progressions. Response at every follow-up with a reference (rows) against the call (columns), automatic setting: HCUCH (23 follow-ups, clinical measurements) and TumorMap (33). Response: complete or partial, merged here ( Tab. 2 scores them apart). With the same 3D models, the fixed pipeline calls progression falsely at 33 of the 56 follow-ups, LesionAgent only twice.
F1
Track
LD ↓
Resp.
LesionAgent, read 1
62.3
75.4
4.0
79.0
LesionAgent, read 2
61.8
73.7
4.5
76.1
LesionAgent, read 3
59.6
68.6
4.4
77.0
Mean ± SD
61.2 ± 1.5
72.6 ± 3.5
4.3 ± 0.3
77.4 ± 1.5
Pipeline
52.2
54.2
8.1
37.0
Claude Code
49.7
37.3
4.4
74.4
Appendix
Table S3 : Run-to-run variability on TumorMap. Three reads of all 33 studies by LesionAgent (Opus 5.5, automatic) with the same code and settings. Read 1 is the one in Tab. 2 . Below, the strongest other automatic methods of Tab. 2 , read once. F1, Track and Resp. in %, LD in mm.
Group
Tool
Input
Output
Perception
detect
visit, text prompts ( e.g . “liver metastasis”)
VoxTell candidates c1,c2,… with size, organ and the prompts that found them. At a follow-up, each candidate’s registered position at baseline, to tell a missed lesion from a new one
totalsegmentator
visit, task
the organ group of every lesion (RECIST counts targets per organ) and node hints, or more candidates from a second detector (lung nodules, liver tumors)
segment ∗
one point or a box, visit, method
a lesion’s mask at a visit from nnInteractive or LongiTrack and its long and short axis. A LongiTrack mask is checked as in track_all
track_all
target visit
every lesion propagated by uniGradICON and segmented by LongiTrack with its earlier mask as context, each with quality flags and an nnInteractive second opinion
refine_lesion
lesion, positive / negative points or scribbles
the mask corrected by nnInteractive, starting from the current mask. undo restores the previous one
edit_mask
lesion, operations
deterministic edits without a model: keep the largest component, remove one, fill holes, clip along an axis, subtract a neighbour
Appendix
Table S4 : Tool reference. The 18 tools with their input and output (typed JSON schemas, served to the model as an in-process MCP server). Every tool returns text, and tools marked ∗ also return an image. Points are voxel indices [z,y,x] .
Model
Input
Encoding
Valid
Found
Resp. (read)
Resp. (only)
s / study
MedGemma 1.5 4B [ 18 ]
40 slices / visit ⋆
grey
3/3
0/25
3/6
0/4
40
40 slices / visit
RGB, 3 windows
1/3
0/6
1/2
1/2
50
85 slices / visit
RGB, 3 windows
0/3
–
–
–
(OOM)
MedGemma 27B [ 54 ]
montage
grey
3/3
0/25
0/6
0/6
190
40 slices / visit
grey
3/3
1/25
5/6
0/6
290
40 slices / visit
RGB, 3 windows
3/3
3/25
5/6
0/6
270
Appendix
Table S5 : One-shot LLM input settings. To show each LLM at its best, we tried several ways of putting a longitudinal CT into it, on a subset of HCUCH patients to save compute (25 measurable reference lesions, 6 follow-ups). Whatever the input, the models find almost no lesions. Table 2 uses the best setting per model ( ⋆ ): 40 grey slices per visit for Qwen3.8 and for MedGemma 1.5, the only MedGemma trained on CT volumes. Valid counts the studies with a parsable answer, Found the measurable reference lesions and Resp. the follow-ups with a correct response, after the full read or when asked only for the response. Values are counts, not balanced accuracy of Tab. 2 .
Figure S2 : Fixed rules vs. LesionAgent on the same follow-up findings in three patients (HCUCH, TumorMap). The pipeline counts every VoxTell finding of at least 10 mm that lies at least 20 mm from all baseline lesions as a new lesion and calls progression. The agent looks at each finding: it rejects normal anatomy (A, B), recognises part of a known metastasis (C) and reads stable disease as the expert does.
Figure S3 : LesionAgent at work, step by step. Six reads on HCUCH and TumorMap, one per row. The left column states the situation, and the row then follows the agent from left to right. A label above each step names it, coloured by who or what runs it (legend). Purple boxes quote the agent’s reasoning, shortened from the run log. Images with yellow or cyan outlines are renders the agent saw, the others are CT crops with the stored masks. The clinician’s answer in row 6 is simulated for illustration. In the evaluation nobody answers, and the agent chose the same set by itself. BL, FU1, FU2: baseline, follow-up 1, 2.
Figure S4 : LesionAgent in napari during a live read of a patient with liver metastases (HCUCH, three visits). Top left: the window, simplified, with the place of each zoom. (a) Visit panels, (b) a clinician question, (c) the lesion registry, (d) the agent’s log, (e) the RECIST report from the guideline engine. The clinician sees every lesion, tool call and number behind the response and can correct any of them.
Tracking tumor lesions across serial CT scans is essential for oncological response assessment. Existing automated methods face a fundamental trade-off: end-to-end trackers achieve high automation but offer no opportunity to correct silent tracking failures, while decoupled registration-segmentation pipelines permit user verification yet discard the lesion's prior appearance, limiting accuracy in ambiguous cases. In this work, we propose a Verified Tracking paradigm: a clinician verifies a registration-proposed prompt, which the model leverages alongside the baseline lesion appearance to resolve segmentation ambiguities. We present a unified framework combining early spatial prompt fusion with latent temporal difference weighting for longitudinally-informed segmentation. To address data scarcity, we leverage large-scale synthetic pretraining, proving essential for exploiting longitudinal context, improving performance by up to 4.5 Dice points over training from scratch. Our approach secured first place in the MICCAI autoPET IV challenge. We further curate and release PanTrack, a new longitudinal pancreatic cancer benchmark, to assess out-of-distribution generalization. Experiments show that our model outperforms prior work in both fully automatic and the proposed verified tracking setting offering a clinically safe middle ground between automation and control. Code, model and dataset will be released at https://github.com/MIC-DKFZ/LongiSeg
Yannick Kirchhoff, Maximilian Rokuss, Daniel Philipp Mertens +5
German Cancer Research Center (DKFZ) Heidelberg, Division of Medical Image Computing, Germany · Faculty of Mathematics and Computer Science, Heidelberg University, Germany · HIDSS4Health – Helmholtz Information and Data Science School for Health, Karlsruhe/Heidelberg, Germany +3
Clinical computed tomography (CT) interpretation inherently requires progressive visual exploration, where radiologists navigate from whole scans to individual slices and regions of interest and interact with external tools when necessary. However, existing 3D medical multimodal large language models (MLLMs) typically connect a specialized 3D visual encoder to a language model, without fully leveraging the native 2D visual and agentic capabilities of generalist MLLMs. Trained on large-scale one-hop CT instruction-following data, these models also have limited ability to perform iterative reasoning and explicitly ground their conclusions in visual evidence, limiting their support for traceable CT interpretation. To solve these problems, we propose agentic perception as an alternative paradigm inspired by radiologists' interpretation workflows. We introduce CT-Navigator, a framework that harnesses generalist MLLMs' 2D visual and agentic capabilities to progressively ground CT interpretation in explicit, traceable visual evidence through hierarchical visual exploration and radiology tool invocation. To build these capabilities, we curate 8,904 visual chain-of-thought (V-CoT) trajectories for cold-start agentic supervised fine-tuning. We then optimize the policy through reinforcement learning on 33,219 questions, with data selection and dynamic rollout sampling prioritizing informative learning signals. Finally, we introduce CTNavi-Bench, a 3D CT visual question answering benchmark comprising 7,000 questions spanning anatomical regions throughout the human body. CT-Navigator achieves 79.50% accuracy on CTNavi-Bench, surpassing the strongest baseline by 17.59%, and demonstrates strong generalization across three external CT benchmarks. The code, model, and benchmark will be released on GitHub.
Yibing Fu, Huidong Xie, Yihao Niu +10
National University of Singapore · JD Health Inc. · Fudan University +2
Dense labels of the aorta in CT are slow to draw, and the public aortic CT datasets that could stand in for them each label different structures under their own conventions. Large language model (LLM) agents can now write code and read images. We asked whether such a model labels these scans better as a free-form agent that writes its own segmentation code, or inside a harness, where an automated pass labels the scan and the model reviews the result. We built a harness, Taurus, and compared it with free-form agents by blind label recovery: we withheld the human labels of six public datasets (939 volumes) and scored every approach against each dataset's own classes. In the first version of Taurus, the model's review raised the primary metric on only two of six datasets, by less than the noise between two reviews of the same case. A free-form agent running Claude Opus 5.5 scored higher on most datasets. Moving what the free-form agents did well into the automated pass then carried most of the gain on 38 held-out cases. The final version smooths the label surfaces with a fixed rule and checks for the large errors the automated pass tends to make, such as an aneurysm drawn to half its size. Each check that fires puts a multiple-choice question to the model, with candidate corrections drawn on the scan. It matched the surface smoothness of the human references, and in the primary metric we found no difference from the free-form Opus agent, at under half its cost, 1.22against2.71 per case. Most of what made Taurus competitive came from the harness and its automation rather than from the language model itself. Taurus shows that this kind of annotation can be automated, so that expert time can move from drawing labels to checking them.
Bing Hu, Rishabh Sharma
David R. Cheriton School of Computer Science, University of Waterloo Waterloo, Ontario, Canada