cs.CVNov 22, 2026

CT-Navigator: Towards Interpretable and Generalizable CT Understanding through Agentic Perception and Tool-Invocation

Authors: Yibing Fu, Huidong Xie, Yihao Niu, Wei Ji, Heming Dong, Ziyue Wang, Jingyu Chen, Jun Zhao, 

Organizations: National University of Singapore · JD Health Inc. · Fudan University · Yale University · 

Abstract

Clinical computed tomography (CT) interpretation inherently requires progressive visual exploration, where radiologists navigate from whole scans to individual slices and regions of interest and interact with external tools when necessary. However, existing 3D medical multimodal large language models (MLLMs) typically connect a specialized 3D visual encoder to a language model, without fully leveraging the native 2D visual and agentic capabilities of generalist MLLMs. Trained on large-scale one-hop CT instruction-following data, these models also have limited ability to perform iterative reasoning and explicitly ground their conclusions in visual evidence, limiting their support for traceable CT interpretation. To solve these problems, we propose agentic perception as an alternative paradigm inspired by radiologists' interpretation workflows. We introduce CT-Navigator, a framework that harnesses generalist MLLMs' 2D visual and agentic capabilities to progressively ground CT interpretation in explicit, traceable visual evidence through hierarchical visual exploration and radiology tool invocation. To build these capabilities, we curate 8,904 visual chain-of-thought (V-CoT) trajectories for cold-start agentic supervised fine-tuning. We then optimize the policy through reinforcement learning on 33,219 questions, with data selection and dynamic rollout sampling prioritizing informative learning signals. Finally, we introduce CTNavi-Bench, a 3D CT visual question answering benchmark comprising 7,000 questions spanning anatomical regions throughout the human body. CT-Navigator achieves 79.50% accuracy on CTNavi-Bench, surpassing the strongest baseline by 17.59%, and demonstrates strong generalization across three external CT benchmarks. The code, model, and benchmark will be released on GitHub.

Figures & tables

Explore similar work

Feb 23, 2026

CT-Flow: Orchestrating CT Interpretation Workflow with Model Context Protocol Servers

Recent advances in Large Vision-Language Models (LVLMs) have shown strong potential for multi-modal radiological reasoning, particularly in tasks like diagnostic visual question answering (VQA) and radiology report generation. However, most existing approaches for 3D CT analysis largely rely on static, single-pass inference. In practice, clinical interpretation is a dynamic, tool-mediated workflow where radiologists iteratively review slices and use measurement, radiomics, and segmentation tools to refine findings. To bridge this gap, we propose CT-Flow, an agentic framework designed for interoperable volumetric interpretation. By leveraging the Model Context Protocol (MCP), CT-Flow shifts from closed-box inference to an open, tool-aware paradigm. We curate CT-FlowBench, the first large-scale instruction-tuning benchmark tailored for 3D CT tool-use and multi-step reasoning. Built upon this, CT-Flow functions as a clinical orchestrator capable of decomposing complex natural language queries into automated tool-use sequences. Experimental evaluations on CT-FlowBench and standard 3D VQA datasets demonstrate that CT-Flow achieves state-of-the-art performance, surpassing baseline models by 41% in diagnostic accuracy and achieving a 95% success rate in autonomous tool invocation. This work provides a scalable foundation for integrating autonomous, agentic intelligence into real-world clinical radiology.
Feb 20, 2026

3DMedAgent: Unified Perception-to-Understanding for 3D Medical Analysis

3D CT analysis spans a continuum from low-level perception to high-level clinical understanding. Existing 3D-oriented analysis methods adopt either isolated task-specific modeling or task-agnostic end-to-end paradigms to produce one-hop outputs, impeding the systematic accumulation of perceptual evidence for downstream reasoning. In parallel, recent multimodal large language models (MLLMs) exhibit improved visual perception and can integrate visual and textual information effectively, yet their predominantly 2D-oriented designs fundamentally limit their ability to perceive and analyze volumetric medical data. To bridge this gap, we propose 3DMedAgent, a unified agent that enables 2D MLLMs to perform general 3D CT analysis without 3D-specific fine-tuning. 3DMedAgent coordinates heterogeneous visual and textual tools through a flexible MLLM agent, progressively decomposing complex 3D analysis into tractable subtasks that transition from global to regional views, from 3D volumes to informative 2D slices, and from visual evidence to structured textual representations. Central to this design, 3DMedAgent maintains a long-term structured memory that aggregates intermediate tool outputs and supports query-adaptive, evidence-driven multi-step reasoning. We further introduce the DeepChestVQA benchmark for evaluating unified perception-to-understanding capabilities in 3D thoracic imaging. Experiments across over 40 tasks demonstrate that 3DMedAgent consistently outperforms general, medical, and 3D-specific MLLMs, highlighting a scalable path toward general-purpose 3D clinical assistants.Code and data are available at https://github.com/jinlab-imvr/3DMedAgent.
Apr 16, 2026

RadAgent: A tool-using AI agent for stepwise interpretation of chest computed tomography

Vision-language models (VLM) have markedly advanced AI-driven interpretation and reporting of complex medical imaging, such as computed tomography (CT). Yet, existing methods largely relegate clinicians to passive observers of final outputs, offering no interpretable reasoning trace for them to inspect, validate, or refine. To address this, we introduce RadAgent, a tool-using AI agent that generates CT reports through a stepwise and interpretable process. Each resulting report is accompanied by a fully inspectable trace of intermediate decisions and tool interactions, allowing clinicians to examine how the reported findings are derived. In our experiments, we observe that RadAgent improves chest CT report generation over its 3D VLM counterpart, CT-Chat, across three dimensions. Clinical accuracy improves by 5.8 points (35.4% relative) in macro-F1 and 5.1 points (18.6% relative) in micro-F1. Robustness under adversarial conditions improves by 24.7 points (41.9% relative). Furthermore, RadAgent achieves 37.0% in faithfulness, a new capability entirely absent in its 3D VLM counterpart. By structuring the interpretation of chest CT as an explicit, tool-augmented and iterative reasoning trace, RadAgent brings us closer toward transparent and reliable AI for radiology.