Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI
Organizations: Institute of Information Processing, Leibniz University Hannover, Hannover, Germany · Medizinische Hochschule Hannover, Hannover, Germany · CAIMED, L3S, Hannover, Germany · Department of Radiology, Charit´e Universitätsmedizin Berlin, Berlin, Germany ·
Abstract
Clinical MRI typically acquires the organ of interest as consecutive stacks of 2D slices in different orientations. Reconstruction methods such as SVRTK and NeSVoR fuse them into one volume and down-weight what does not fit, although in living tissue the change during the scan is often the signal itself and can contain clinically relevant physiological information, such as fetal motion and uterine contraction. We propose an analysis-by-synthesis decomposition that explains every acquired voxel through its exact acquisition geometry as a static anatomy shared by all stacks, a rigid and smooth non-rigid motion per stack, and a sparse transient field per stack for changes during one acquisition only. A robust reweighting keeps such changes out of the anatomy. The model is fitted per subject without training data, with one configuration for all datasets. On a digital phantom with known ground truth, static changes are kept entirely in the anatomy, and the transient field of the stack that saw a transient recovers 68% of it at 12mm radius. From identical inputs, the anatomy predicts held-out stacks better than SVRTK and NeSVoR on uterine (NCC 0.897 against 0.874 and 0.863, 123 patients) and on prostate MRI from unseen sites and scanners (0.847 against 0.795 and 0.757, 85 patients), and on fetal brain MRI as well as SVRTK and better than NeSVoR (0.771 against 0.763 and 0.747, 83 fetuses). The transient fields flag corrupted fetal slices with an AUROC of 0.94 against expert raters. As the input of a frozen anomaly detector trained on healthy subjects only, the anatomy localizes radiologist-delineated uterine lesions better than the SVRTK and NeSVoR volumes (AUROC 0.76 against 0.71 and 0.71, 37 patients).
Figures & tables
| Uterus | Prostate | |
|---|---|---|
| vs. ground truth, NCC | ||
| Motion error, mm (applied ) | ||
| Static change found in (ideal 1) | ||
| Transient in own , mm | ||
| Transient leaked into | – | – |
| Ours ( ) | SVRTK | NeSVoR | Mean of stacks | ||||
| aligned | unaligned | ||||||
| Uterus | Seen | NCC | 0.934 | 0.951 | 0.946 | – | – |
| SSIM | 0.608 | 0.791 | 0.757 | – | – | ||
| PSNR | 23.8 | 24.7 | 24.1 | – | – | ||
| Held out | NCC | 0.897 | 0.874 | 0.863 | 0.870 | 0.835 | |
| SSIM | 0.486 | 0.446 | 0.446 | 0.432 | 0.386 | ||
Appendix figures & tables5 assets
Supplementary material from the paper’s appendix.
Appendix
| Experiment (question) | Data | Setup and parameters | Evaluation |
| Reconstruction | |||
| Held-out stack prediction (Sec. 3.3 ) Does the volume predict an acquisition it has not seen? | U: all 123 patients, 369 cases (cases scored where every method returned a volume) F: 83 fetuses = 65 healthy test fetuses + 18 with pathology, 249 cases (one stack without a usable brain mask) P: the 85 healthy test patients, 255 cases | Each stack left out in turn, all methods reconstruct from the remaining stacks. frozen, stack registered anew to every volume (rigid, non-rigid, gain, offset and smooth bias, 400 iterations, no transient) and simulated through its slice profile. Methods: ours, SVRTK (template by fixed rule), NeSVoR (SVoRT for F, stack registration for U and P), mean of the other stacks with and without our motion correction. | NCC, SSIM, PSNR in a common region (U, P: organ + 10 mm, F: brain mask), also after a common in-plane low-pass ( = 1, 2, 4 mm) and per frequency band, median over cases, per-patient Wilcoxon test, better if median difference favors a method and . |
| Seen-stack consistency (Sec. 3.3 ) How closely does the volume reproduce its own inputs? | The same subjects as above: U 123, F 83, P 85 | Same registration and simulation as above, applied to every stack the volume was reconstructed from. | As above. Interpreted together with the held-out result, since keeping single-stack changes raises this score. |
| Separation | |||
| Digital phantom (Sec. 3.2 ) Are static and transient changes attributed to the right component? | U, P: 20 patients each, seeded draw (U: among the patients with an SVRTK reconstruction, without the patients of the benchmarks used for the configuration, P: among the 85 test patients) | Ground truth : SVRTK reconstruction. Simulated stacks with motion , mm, smooth deformation 1–3 mm, trapezoidal slice profile, in-plane blur, per-slice jitter 0.3 mm, polynomial bias , Rician noise. Per patient one case without and two with changes: two transients (one stack each, spheres , 8 or 12 mm, contrast ), one compression up to 3 mm (one stack), one static change (all stacks). | NCC and SSIM of against ground truth, motion error (mm), share of each change in and in its (projection onto the inserted change, change isolated by subtracting the unchanged case). |
| Ablation (Sec. D ) Which parts of the model matter? | U, F: 20 patients each, seeded draw from the training split U phantom: the 20 phantoms above and a harder variant F: the corruption benchmark below | One change at a time: rigid only, no , no robust reweighting, from the non-rigid stage, reference stack instead of centered gauge, no slice profile, down to 2 mm, grid 4 / 2 mm. Our configuration refitted with another seed as reference for the refit variability. Hard phantom: noise , jitter 1 mm, texture 5%. | Median per-patient held-out NCC difference to ours, phantom share of transients in and , SSIM of , flagging AUROC. |
| Static pathology | |||
| Lesion insertion benchmark (Sec. C ) Which input should the detector use? | U, F, P: 20 healthy test subjects each (U: all 20 test patients, F, P: seeded draw from the test split), 2 cases per subject | Per case three static lesions (all stacks, contrast , , 5, 8 or 12 mm, inside the organ or at its boundary, mm apart) and two transient distractors (one stack, contrast , or 8 mm, mm from other changes), rendered through each stack’s fitted motion, slice profile, gain and bias, then refitted. Candidates (U, F, P): , mean of the motion-corrected stacks, that mean weighted by and , second-largest stack, with 2 mm grid. | Pre-registered criterion: mean over strata (contrast size location) of the median voxel AUROC, the simplest candidate within 0.01 of the best wins. Share of distractor voxels with . |
| Real lesion detection (Sec. C ) How well does each input localize real lesions? | U: the 37 patients with radiologist masks in every stack showing the lesion F: the 18 fetuses with pathology P: the 47 patients with clinically significant cancer and an expert delineation (axial stack) | Frozen detector: PatchCore on DINOv3 tokens at two scales (8 and 16 mm), PCA and memory from the healthy training subjects (U: 40, F: 196, P: 118, i.e. training split without the 10 calibration subjects), tail calibration on these 10 held-out healthy subjects, , maximum over scales, Gaussian smoothing 1.5 mm. Evaluated once, U also per finding and without deep infiltrating endometriosis (declared from the radiologist’s rating of label reliability). P: with the frozen detector, the other inputs with banks rebuilt for the selection. | Per-patient voxel AUROC of lesion voxels against all others in organ + 40 mm seen by stacks, excluding 3 mm around each lesion, lesions in and stacks (P: ), by polarity. False positives: share of healthy voxels with . |
| Detector on SVRTK and NeSVoR (Sec. C ) Is a better input than SVR volumes? | Benchmark: U 37 cases (SVRTK failed on 3 of 40), F 40, P 40 Real lesions: U 37 patients, F 18 fetuses | benchmark cases with all three inputs Same detector, PCA and memory rebuilt per input from that input’s healthy training subjects, volumes registered rigidly to , one common region. | Benchmark criterion as above, better if ahead by more than 0.02. Real lesions: per-patient AUROC, Wilcoxon test. |
| Normative model (Sec. C ) Memory bank or normalizing flow? | U, F: insertion benchmark | Same tokens and held-out calibration, nearest-neighbor memory against a normalizing flow. | Benchmark criterion, on training against unseen healthy subjects. |
| Same-cohort fetal reference (Sec. C ) Does the cohort shift inflate the fetal results? | F: 165 healthy control fetuses of the cohort and protocol of the fetuses with pathology (25% test, seeded, one without coverage skipped), the 18 fetuses with pathology | Frozen detector, PCA, memory and calibration rebuilt from the training controls of that cohort, inputs and the mean of the motion-corrected stacks. Declared before running. | Lesion AUROC of the 18 fetuses against the original reference, patient-level AUROC against the held-out controls of the same cohort. |
| Single-vendor reference (Sec. C , exploratory) Does scanner heterogeneity explain the prostate result? | P: Siemens 31 / 69 / 102, Philips 16 / 16 / 26 (diseased / test / training) | PCA, memory and calibration from the healthy training subjects of one vendor, declared before running. | As for real lesions, plus gland volume as a confound. |
| Input | Uterus (37) | Fetal (18) | Prostate (47) | Healthy FP (uterus) |
|---|---|---|---|---|
| 0.74 / 0.76 | 0.88 / 0.93 | 0.38 / – | 0.34% | |
| Mean of motion-corrected stacks | 0.77 / 0.79 | 0.89 / 0.95 | 0.47 / – | 0.23% |
| Mean, weighted by and | 0.72 / 0.74 | 0.69 / 0.63 | 0.63 / – | 0.01% |
| Second-largest stack | 0.71 / 0.67 | 0.84 / 0.90 | 0.45 / – | 0.02% |
| , 2 mm grid | 0.70 / 0.68 | 0.88 / 0.92 | 0.42 / – | 0.06% |
| Separation (phantom) | Flagging | Fidelity, NCC | |||
| / | SSIM | AUROC | Uterus | Fetal | |
| Ours | 0.66 / 0.08 | 0.899 | 0.90 | – | – |
| Ours, other seed | 0.65 / 0.09 | 0.898 | – | ||
| Transient field | |||||
| No , rigid only | – / 0.23 | 0.873 | – | ||
| No , non-rigid | – / 0.27 | 0.882 | – | ||
Image Reconstruction
Image reconstruction recovers images, volumes, or scenes from incomplete, noisy, indirect, or compressed measurements using physical models and learned priors.
See all 326 papers