eess.IVNov 20, 2026

Beyond Outlier Rejection: Transient-Aware Reconstruction of Multi-Stack MRI

Authors: Anika Knupfer, Maximilian Lindholz, Maria Camila Bustos-Vivas, Joseph V. Hajnal, Bodo Rosenhahn, Jana Hutter

Organizations: Institute of Information Processing, Leibniz University Hannover, Hannover, Germany · Medizinische Hochschule Hannover, Hannover, Germany · CAIMED, L3S, Hannover, Germany · Department of Radiology, Charit´e Universitätsmedizin Berlin, Berlin, Germany · 

Abstract

Clinical MRI typically acquires the organ of interest as consecutive stacks of 2D slices in different orientations. Reconstruction methods such as SVRTK and NeSVoR fuse them into one volume and down-weight what does not fit, although in living tissue the change during the scan is often the signal itself and can contain clinically relevant physiological information, such as fetal motion and uterine contraction. We propose an analysis-by-synthesis decomposition that explains every acquired voxel through its exact acquisition geometry as a static anatomy shared by all stacks, a rigid and smooth non-rigid motion per stack, and a sparse transient field per stack for changes during one acquisition only. A robust reweighting keeps such changes out of the anatomy. The model is fitted per subject without training data, with one configuration for all datasets. On a digital phantom with known ground truth, static changes are kept entirely in the anatomy, and the transient field of the stack that saw a transient recovers 68% of it at 12mm radius. From identical inputs, the anatomy predicts held-out stacks better than SVRTK and NeSVoR on uterine (NCC 0.897 against 0.874 and 0.863, 123 patients) and on prostate MRI from unseen sites and scanners (0.847 against 0.795 and 0.757, 85 patients), and on fetal brain MRI as well as SVRTK and better than NeSVoR (0.771 against 0.763 and 0.747, 83 fetuses). The transient fields flag corrupted fetal slices with an AUROC of 0.94 against expert raters. As the input of a frozen anomaly detector trained on healthy subjects only, the anatomy localizes radiologist-delineated uterine lesions better than the SVRTK and NeSVoR volumes (AUROC 0.76 against 0.71 and 0.71, 37 patients).

Figures & tables

Appendix figures & tables5 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. M-Gaussian: An Magnetic Gaussian Framework for Efficient Multi-Stack MRI Reconstruction

    Feb 24, 2026Kangyuan Zheng, Xuan Cai, Jiangqi Wang +6Magnetic Resonance Imaging3D Gaussian Splatting

  2. PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

    Jul 22, 2026Busra Bulut, Maik Dannecker, Thomas Sanchez +14Fetal MRIImplicit Neural Representations

  3. MK-ResRecon: Multi-Kernel Residual Framework for Texture-Aware 3D MRI Refinement from Sparse 2D Slices

    May 5, 2026Prajyot Pyati, Sapna Sachan, Amulya Kumar Mahto +13D Medical ImagingImage Reconstruction