Learning deformable physical world models requires dynamics that generalize beyond observed motion. Accurate reconstruction alone does not ensure accurate future prediction, motivating us to learn how observations should influence physical identification. However, visual reliability alone does not determine how informative an observation is about physical dynamics. We propose ViTrust to learn 3D observation trust, determining how strongly each tracked point influences physical identification. Its key design is a visual-contact trust adapter that combines pointwise spatiotemporal evidence with interaction history on a persistent contact graph to predict time-varying observation weights. A single-stage, shared-forward objective jointly optimizes these weights and physical parameters through weighted geometry and correspondence losses, with constraints to prevent observation-weight collapse. All learning uses only the observed prefix. The fitted physics remains fixed for future prediction under supplied controls. Experiments on real-world sequences demonstrate improved future prediction over the evaluated baselines, alongside qualitative demonstrations of novel-control rollouts and cross-object transfer.
Figures & tables
Figure 2: Consistent gains in future physical prediction. Scene-equal averages over 22 sequences and 735 future frames, normalized to PhysTwin (100); outward is better. Outer bands group geometry and motion (teal) and appearance quality (purple). Blue labels show gains over PhysTwin.
Figure 3: Overview of ViTrust . (a) Pointwise Spatiotemporal Evidence. Depth-consistent sampling of frozen VideoMAE features, combined with depth and motion cues, forms pointwise spatiotemporal descriptors. (b) Visual–Contact Observation Trust. Contact graph message passing and a temporal GRU encode interaction history on persistent patches defined by fixed point-to-anchor assignments. Patch-level contact adjustments are broadcast back to points and fused with pointwise visual scores to predict relative observation weights Wψ for physical identification. (c) Single-Stage Training. A regularized objective jointly updates physical parameters θ and adapter parameters ψ through trust-weighted geometry and tracking losses from a shared forward simulation on the observed prefix. (d) Future Prediction. Frozen physical parameters predict motion under future controls without refitting or future object observations, with 3D Gaussians used for rendering. Flame and snowflake symbols indicate optimized and frozen components, respectively.
Figure 4: Focused reconstruction and future-prediction comparison. We select four interactions with large future-frame CD reductions. Each interaction pairs calibration reconstruction (left) with future prediction (right). RGB renders and geometric errors use the same frame and predicted trajectory, with shared crops and local zoom-in regions across methods. Error maps show one-sided L1 distances from common visible GT points to each predicted surface, using a shared color scale. The arrow indicates increasing pointwise error from blue (0 mm) to red ( ≥30 mm). Colors saturate at 30 mm; labels report full-frame PSNR (dB) and mean CD (mm), not inset-only metrics. Mean CD is computed from unclipped distances. MatPhys uses the public-checkpoint configuration in Appendix E . DeformMaster (NeurIPS 2026) uses the configuration in Appendix E .
Figure 5: Cross-object physics transfer under three scripted controls. Frozen parameters identified from Lift Sloth are transferred to a static plush-dog reconstruction [ 17 ] , without fitting target motion.
Reconstruction & Resimulation
Future Prediction
Method
CD ↓
Track ↓
IoU ↑
PSNR ↑
SSIM ↑
LPIPS ↓
CD ↓
Track ↓
IoU ↑
PSNR ↑
SSIM ↑
LPIPS ↓
Spring-Gaus (ECCV 2024)
31.24
37.36
64.99
25.38
93.91
6.50
63.75
92.40
38.94
21.89
91.96
11.12
GS-Dynamics (CoRL 2024)
39.65
56.06
49.95
22.77
92.78
9.64
49.23
105.66
20.18
21.38
92.07
12.63
PhysTwin (ICCV 2025)
5.59
9.36
74.91
26.27
94.35
3.98
13.11
26.40
61.79
24.38
93.66
6.53
MatPhys (arXiv 2026)
16.02
25.14
68.99
25.50
94.04
5.01
30.68
48.86
53.01
23.26
93.07
7.95
DeformMaster (NeurIPS 2026)
6.12
11.36
80.86
29.33
95.87
3.41
19.95
38.49
57.65
24.14
93.52
8.33
Table 1: Reconstruction/resimulation and future prediction on 22 scenes. Scene-equal means for the calibration prefix (left) and 735 held-out future frames (right); tracking uses available manual annotations. Distances are in mm; PSNR in dB; SSIM, LPIPS, and IoU are scaled by 100 . Baseline-specific settings are in Appendix E . Best and second-best numerical values across displayed rows are bold and underlined, using unrounded values.
Reconstruction & Resimulation
Future Prediction
Variant
CD ↓
Track ↓
IoU ↑
PSNR ↑
SSIM ↑
LPIPS ↓
CD ↓
Track ↓
IoU ↑
PSNR ↑
SSIM ↑
LPIPS ↓
Visual trust only
5.72
10.36
75.28
26.46
94.39
3.95
13.06
26.72
62.53
24.51
93.72
6.43
Contact-graph trust only
5.54
9.88
75.11
26.29
94.36
3.98
12.77
25.35
63.37
24.69
93.79
6.24
Frame-wise (no GRU)
5.51
9.73
75.28
26.34
94.37
3.94
12.83
25.07
62.74
24.56
93.78
6.28
w/o Weight regularization
5.63
10.07
74.97
26.24
94.32
4.03
13.08
26.10
62.14
24.40
93.66
6.51
CoTracker confidence
5.49
9.74
75.24
26.30
94.37
3.95
12.91
25.32
62.46
24.48
93.73
6.37
Table 2: Observation-weighting ablations. Scene-equal means over 22 scenes; units follow Table 1 . Bold ranks learned-weight variants. Heuristics follow Appendix F ; per-scene results are in Tables 6 and 7 .
Appendix figures & tables6 assets
Supplementary material from the paper’s appendix.
Appendix
Quantity
Shape
RGB Itν
Tc×V×HI×WI×3
Depth Dtν
Tc×V×HI×WI
Tracks yt,p
Tc×P×3
Masks mt,p
Tc×P
Controllers ct,j
Tc×30×3
VideoMAE maps HVM
Nclip×8×14×14×768
Appendix
Table 3: Calibration tensor shapes for one scene. VideoMAE maps are listed per camera view.
Figure 6: Temporal evolution of single-stage observation trust on Lift Cloth 3. Rows show RGB observations, frozen VideoMAE similarity, and learned pointwise weights at four calibration times. As deformation evolves, the weights become spatially differentiated beyond the raw similarity cue. Bottom: empirical probability densities of visible weights and relative effective sample size (rESS). The dashed line marks neutral influence ( w=1 ). The distributions broaden from their initially concentrated profile, revealing down-weighted ( w<1 ) and up-weighted ( w>1 ) observations, while rESS stays above the prescribed 0.7 floor, indicating selectivity without weight collapse. Gray points are unavailable observations and are excluded from both statistics. No retraining, weight renormalization, or temporal interpolation is applied.
Reconstruction & Resimulation
Physical (mm)
Rendering (PSNR: dB; others: ×100 )
Scene
Method / Variant
CD ↓
Track ↓
RMSE ↓
Median ↓
P95 ↓
PSNR ↑
SSIM ↑
LPIPS ↓
IoU ↑
Cloth Lift 1 (C)
Spring-Gaus (ECCV 2024)
10.64
10.54
12.37
8.85
20.08
27.59
95.15
4.85
91.80
GS-Dynamics (CoRL 2024)
12.48
25.60
26.67
25.61
36.11
24.28
94.44
7.47
80.92
PhysTwin (ICCV 2025)
3.04
3.33
4.12
2.42
7.29
27.57
95.19
3.58
91.65
MatPhys (arXiv 2026)
3.92
8.39
8.65
8.50
10.84
27.41
95.13
4.08
91.48
DeformMaster (NeurIPS 2026)
3.33
4.26
4.59
4.22
6.71
32.44
97.82
2.30
95.35
Appendix
Table 4: Per-scene baseline results: reconstruction and resimulation. Each scene includes five baselines and the full ViTrust model (shaded). Distances are in mm; PSNR in dB; SSIM, LPIPS, and IoU are scaled by 100 . Each method follows its native protocol. Baseline settings are in Appendix E . Best and second-best numerical values among the six displayed rows within each scene are bold and underlined, using unrounded values.
Future Prediction
Physical (mm)
Rendering (PSNR: dB; others: ×100 )
Scene
Method / Variant
CD ↓
Track ↓
RMSE ↓
Median ↓
P95 ↓
PSNR ↑
SSIM ↑
LPIPS ↓
IoU ↑
Cloth Lift 1 (C)
Spring-Gaus (ECCV 2024)
18.20
18.00
21.70
13.68
38.91
25.49
94.18
7.02
85.32
GS-Dynamics (CoRL 2024)
15.93
38.98
53.97
31.69
98.08
20.66
92.52
12.76
62.36
PhysTwin (ICCV 2025)
10.81
26.95
28.75
23.73
42.24
23.63
93.76
6.77
82.75
MatPhys (arXiv 2026)
7.59
17.26
17.98
16.92
24.55
24.95
94.03
6.24
86.73
DeformMaster (NeurIPS 2026)
11.45
15.62
16.69
15.17
24.10
26.13
96.04
5.36
87.51
Appendix
Table 5: Per-scene baseline results: future prediction. Each scene includes five baselines and the full ViTrust model (shaded). Distances are in mm; PSNR in dB; SSIM, LPIPS, and IoU are scaled by 100 . Baseline settings are in Appendix E . Best and second-best numerical values among the six displayed rows within each scene are bold and underlined, using unrounded values. Lift Dinosaur tracking metrics use the same 23 annotated future frames as ViTrust; CD and rendering use all 26 frames.
Reconstruction & Resimulation
Physical (mm)
Rendering (PSNR: dB; others: ×100 )
Scene
Method / Variant
CD ↓
Track ↓
RMSE ↓
Median ↓
P95 ↓
PSNR ↑
SSIM ↑
LPIPS ↓
IoU ↑
Cloth Lift 1 (C)
Visual trust only
4.39
11.66
11.81
11.44
14.48
31.18
95.96
2.89
95.58
Contact-graph trust only
3.02
3.32
4.14
2.43
7.29
27.68
95.17
3.68
91.75
Frame-wise (no GRU)
3.07
3.34
4.16
2.45
7.33
27.69
95.17
3.67
91.75
w/o Weight regularization
3.73
5.29
5.86
4.76
9.19
26.53
94.88
4.12
89.61
CoTracker confidence
3.21
3.63
4.43
2.90
7.79
27.29
95.16
3.68
91.01
Appendix
Table 6: Per-scene ablation results: reconstruction and resimulation. Each scene includes seven ablation variants and the full ViTrust model (shaded). Distances are in mm; PSNR in dB; SSIM, LPIPS, and IoU are scaled by 100 . Definitions and protocol differences are given in Appendix F . Best and second-best numerical values among the six learned-weight rows within each scene are bold and underlined, using unrounded values.
Future Prediction
Physical (mm)
Rendering (PSNR: dB; others: ×100 )
Scene
Method / Variant
CD ↓
Track ↓
RMSE ↓
Median ↓
P95 ↓
PSNR ↑
SSIM ↑
LPIPS ↓
IoU ↑
Cloth Lift 1 (C)
Visual trust only
9.38
24.66
25.23
23.27
33.32
25.20
94.16
6.09
87.04
Contact-graph trust only
5.09
9.61
12.70
6.05
23.94
27.12
94.72
4.12
93.15
Frame-wise (no GRU)
7.73
16.02
18.35
13.17
30.96
25.47
94.38
4.98
89.29
w/o Weight regularization
9.25
21.68
23.75
18.78
37.18
24.46
94.20
5.83
86.54
CoTracker confidence
8.81
19.42
21.66
17.91
35.23
24.85
94.29
5.36
87.63
Appendix
Table 7: Per-scene ablation results: future prediction. Each scene includes seven ablation variants and the full ViTrust model (shaded). Distances are in mm; PSNR in dB; SSIM, LPIPS, and IoU are scaled by 100 . Definitions and protocol differences are given in Appendix F . Best and second-best numerical values among the six learned-weight rows within each scene are bold and underlined, using unrounded values. Lift Dinosaur tracking metrics use the same 23 annotated future frames as ViTrust; CD and rendering use all 26 frames.