Is the learner or the summary the limit? Auditing machine-learning energy reconstruction for air-shower arrays on KASCADE and GRAPES-3
Organizations: Department of Computer Science and Engineering, Indian Institute of Technology Jodhpur, Jodhpur, India. · Department of Computer Science, Ashoka University, Sonipat, Haryana, India
Abstract
Machine-learning energy estimators for cosmic-ray arrays are usually trained on a few fitted shower parameters, not station signals. When their resolution stops improving, standard diagnostics cannot say whether a better model would help or the summary has run out of information. We use a five-step audit that compares trained models with a learner-independent estimate of the lowest error the summary allows (its squared-loss Bayes risk, or floor), tests which inputs add information and flags inputs merely computed from the fit. We apply it to public KASCADE simulations with three hadronic-interaction models (QGSJET-II-04, EPOS-LHC and SIBYLL-2.3d), to 13,848,509 measured KASCADE events and to simulated GRAPES-3 events. Within known energy decades below 10^16 eV, gradient boosting on nine reconstructed features is within 2.2% of the estimated floor under every estimator setting, so more capacity is not expected to gain more than about 2%. The floor is an estimate, accurate to about 1% in a semi-synthetic benchmark with intervals that under-cover, and not a bound on the true Bayes risk. Replacing reconstructed by true particle numbers removes 70 to 72% of the error variance below 10^15 eV and 24 to 26% between 10^16 and 10^17 eV on all three models, yet simulated station signals close about a tenth of that gap. On GRAPES-3, networks given images rendered from the fit do no better than the fit. In measured data, the mean muon size at fixed electron size lies within every model's proton-to-iron bracket and a label-free probe finds the muon channel used as in simulation; neither fixes the energy scale. Energy-labelled results are simulated.
Figures & tables
| Question | Result | Sec. |
|---|---|---|
| Is the learner the limit below eV? | Boosting within of the estimated floor | 4 |
| How does the fixed KCDC formula compare? | Calibrated, – above the floor estimate | 4.2 |
| What do reconstructed sizes cost? | – of error variance below eV; – at – eV | 4.4 |
| How much do station networks recover? | – of the oracle gap | 4.6 |
| Does a rendered image help on GRAPES-3? | No new information: CNN , boosting on the fit | 6 |
| model | events | boosting | floor est. | excess | interval | oracle | oracle gap | |
|---|---|---|---|---|---|---|---|---|
| – | QGSJET-II-04 | |||||||
| EPOS-LHC | ||||||||
| SIBYLL-2.3d | ||||||||
| – | QGSJET-II-04 | |||||||
| EPOS-LHC | ||||||||
| SIBYLL-2.3d |
| KCDC estimate | bias spread across primaries | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| model | boosting | floor est. | raw (bias) | calibrated | above floor | boosting | KCDC | oracle | |
| – | QGSJET-II-04 | ( ) | |||||||
| EPOS-LHC | ( ) | ||||||||
| SIBYLL-2.3d | ( ) | ||||||||
| – | QGSJET-II-04 | ( ) | |||||||
| EPOS-LHC | ( ) | ||||||||
| boosting, nine features | KCDC estimate | lost to reconstruction | ||||||
|---|---|---|---|---|---|---|---|---|
| model | per decade | generated | flat | calibrated | raw | per decade | flat | |
| – | QGSJET-II-04 | |||||||
| EPOS-LHC | ||||||||
| SIBYLL-2.3d | ||||||||
| – | QGSJET-II-04 | |||||||
| EPOS-LHC | ||||||||
| floor | + station | + image | gap closed | network features | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| model | test | boosting | estimate | oracle | features | network | features | network | (paired interval) | |
| – | QGSJET | |||||||||
| EPOS | ||||||||||
| SIBYLL | ||||||||||
| – | QGSJET | |||||||||
| EPOS | ||||||||||
| mean | distance to data | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| events | model | data | proton | mixture | iron | proton | mixture | iron | |
| 14–15 | QGSJET-II-04 | ||||||||
| EPOS-LHC | |||||||||
| SIBYLL-2.3d | |||||||||
| 15–16 | QGSJET-II-04 | ||||||||
| EPOS-LHC | |||||||||
| input and model | predicted | random split | shower cross-fit | |
|---|---|---|---|---|
| A | four fit parameters , gradient boosting | |||
| B | CNN on image rendered from | |||
| C | CNN on rendered image 16 measured muon counts | |||
| C ′ | 16 muon counts, gradient boosting | — | — | |
| C ′′ | as C ′ zenith angle | — | — | |
| D | nine features, gradient boosting |
Appendix figures & tables10 assets
Supplementary material from the paper’s appendix.
Appendix
| random split | shower cross-fit | |
| Learned estimators, nine features | ||
| Ridge (10 coefficients) | ||
| Random forest | ||
| Gradient boosting | ||
| MLP | ||
| XGBoost | — | |
| Representation | true floor | error | best learned | |
|---|---|---|---|---|
| summary (six numbers) | ||||
| and measured channel | ||||
| , and noise-scale channel | ||||
| measurement (32 numbers) | ||||
| image rendered from , CNN | — | — |
| model | fit | + zenith | + muon size | |
|---|---|---|---|---|
| – | QGSJET-II-04 | |||
| EPOS-LHC | ||||
| SIBYLL-2.3d | ||||
| – | QGSJET-II-04 | |||
| EPOS-LHC | ||||
| SIBYLL-2.3d |
| boosting above floor est. (%) | bias of est. | ||||||
|---|---|---|---|---|---|---|---|
| sample | model | boosting | floor est. (ref.) | ref. | interval | all settings | (benchmark, %) |
| – (stations) | QGSJET | ||||||
| EPOS | |||||||
| SIBYLL | |||||||
| – | QGSJET | ||||||
| EPOS | |||||||
| sample | model | reference | shower interval | – | 3 scalings | Manhattan | six coord. | direct 1-NN |
|---|---|---|---|---|---|---|---|---|
| – (stations) | QGSJET | – | – | |||||
| EPOS | – | – | ||||||
| SIBYLL | – | – | ||||||
| – | QGSJET | – | – | |||||
| EPOS | – | – | ||||||
| SIBYLL | – | – |
| bias of the floor estimate (%) | coverage | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| sample | model | true floor | reference | – | robust | rank | Manhattan | six coord. | 1-NN | of interval |
| – (stations) | QGSJET | to | ||||||||
| EPOS | to | |||||||||
| SIBYLL | to | |||||||||
| – | QGSJET | to | ||||||||
| EPOS | to | |||||||||
| Encoder | size | image only | range | correction | range | gap closed |
|---|---|---|---|---|---|---|
| small CNN | 0.2 M | – | – | |||
| residual network | 6.3 M | – | – | |||
| station transformer | 1.2 M | – | – | |||
| graph network | 0.4 M | – | – | |||
| graph net., absolute pos. | 0.4 M | – | – |
High-Energy Physics
High-energy physics studies the fundamental particles and forces of nature through collider, neutrino, cosmic-ray, and theory-driven experiments.
See all 184 papers