Organizations: College of Computer Science and Software Engineering and School of Artificial Intelligence, Shenzhen University, Shenzhen, China · Department of Oral and Maxillofacial Surgery, Digital Center of Stomatology, The Affiliated Stomatology Hospital, Kunming Medical University, China
Salivary gland tumors are common lesions in oral and maxillofacial practice, and accurate identification of tumor regions and surrounding salivary gland tissues is important for tissue assessment, pathological sampling, and clinical decision support. Hyperspectral imaging (HSI) records continuous spectral responses together with spatial imaging information, providing a promising way to capture fine-grained tissue-discriminative information. Nevertheless, the development of salivary gland HSI tissue segmentation remains limited due to the lack of standardized benchmarks with pixel-level annotations and unified evaluation protocols. To address this issue, we introduce SalivaryHSI-Seg, a hyperspectral tissue segmentation benchmark for ex vivo salivary gland specimens, containing 119 HSI samples from 31 patients with multi-class pixel-level annotations. We establish a patient-level five-fold cross-validation protocol and evaluate different input representations, model architectures, and challenging subsets with small tumor and complex boundary. Based on this benchmark, we further propose HyBSD, a hyperspectral boundary-guided spectral-difference network for full-HSI salivary gland tissue segmentation. HyBSD exploits boundary-guided spectral-difference cues to improve tissue delineation in ambiguous transition regions. Extensive experiments show that full-HSI input provides more discriminative information than sampled spectrums, and that HyBSD achieves 74.97% mDice and 87.76% Tumor Dice, with further advantages on the challenging subsets. Dataset and code will be released.
Figures & tables
Dataset
Acquisition
Spectral Information
Dataset Size
Annotations
Target
Setting
Bands
Range (nm)
Specimens
HSI
Pixel Mask
Dense Labels
Classes
ODSI-DB [ 10 ]
Oral/dental
In vivo
51; 204
450–950; 400–1000
30
316
△
—
35
HELICoiD [ 5 ]
Brain
In vivo
826
400–1000
22
36
△
—
4
SLIMBRAIN [ 15 ]
Brain
In vivo
25; 369
660–950; 400–1000
193
193
△
—
19
Leipzig HSI [ 18 ]
Thyroid/GI
In vivo
100
500–1000
100
NR
△
—
15
Placenta HSI [ 19 ]
Placenta
Ex vivo
38–78
515–700; 515–900
4
101
✓
△
4
Table 1: Comparison of representative medical HSI datasets for human tissue analysis.
Figure 1: Overview of SalivaryHSI-Seg. Tumor in the spectral curves denotes the diagnosis-specific tumor category in the selected sample.
Figure 2: Spatial and spectral characteristics of SalivaryHSI-Seg.
Figure 3: Overview of the proposed boundary-aware full-HSI segmentation framework.
Metric
Category
Pseudo-RGB
PCA-3
5 Bands
Full HSI
Dice ↑
Overall
53.58 ± 9.52
30.66 ± 3.48
56.14 ± 7.18
67.22 ± 9.79
Tumor
60.05 ± 12.36
29.82 ± 5.34
64.16 ± 9.77
75.56 ± 13.22
IoU ↑
Overall
43.33 ± 9.96
22.93 ± 3.26
45.98 ± 8.56
58.99 ± 11.21
HD95 ↓
Overall
257.39 ± 43.72
237.49 ± 52.58
246.90 ± 42.73
190.57 ± 61.22
Specificity ↑
Overall
96.25 ± 1.76
94.27 ± 1.93
97.00 ± 1.31
97.91 ± 1.59
Table 2: Comparison of different input representations using the same 2D U-Net architecture. Dice, IoU, and specificity are reported in percentage; HD95 is reported in pixels.
2D CNN
3D CNN
3D Transformer
Metric
Category
2D U-Net
3D U-Net
VNet
SegResNet
HyBSD (Ours)
UNETR
SwinUNETR
HyBSD-Swin
Dice ↑
Overall
67.22 ± 9.79
62.61 ± 9.08
46.97 ± 4.90
60.21 ± 6.84
74.97 ± 7.90
38.43 ± 13.23
56.83 ± 13.73
66.87 ± 10.87
Gland
59.05 ± 11.48
46.37 ± 10.51
25.83 ± 7.03
43.50 ± 5.40
61.65 ± 11.71
29.94 ± 7.04
42.94 ± 11.77
55.93 ± 12.61
Conn
61.98 ± 9.33
53.11 ± 8.86
43.03 ± 4.58
50.04 ± 4.16
62.71 ± 7.25
31.36 ± 13.15
42.45 ± 19.23
59.32 ± 4.22
PA
74.87 ± 16.23
78.34 ± 12.10
66.43 ± 22.74
65.04 ± 28.04
84.19 ± 10.75
60.05 ± 11.16
62.65 ± 20.11
78.31 ± 12.27
WT
89.76 ± 8.68
72.63 ± 28.59
52.59 ± 30.24
82.27 ± 14.59
91.33 ± 8.88
32.38 ± 44.70
79.29 ± 16.28
73.91 ± 31.07
Table 3: Full-HSI benchmark results. Dice, IoU, and specificity are reported in percentage; HD95 is reported in pixels.
Small tumor: 36 (15/21)
Method
Tumor Dice ↑
Tumor HD95 ↓
mDice p ↑
Full-HSI U-Net
61.46 ± 38.07
360.01 ± 408.22
69.20 ± 18.76
SegResNet
60.16 ± 38.70
360.19 ± 427.20
61.51 ± 21.87
HyBSD (Ours)
76.29 ± 35.71
166.09 ± 335.00
75.07 ± 21.20
Complex boundary: 36 (24/12)
Method
Tumor Dice ↑
Tumor HD95 ↓
mDice p ↑
Table 4: Results of challenging subsets.
Figure 4: Qualitative segmentation results on representative and challenging samples. Correct Tumor denotes the diagnosis-consistent tumor class, Wrong Tumor denotes the other tumor class, and Unlabeled denotes unannotated regions.
Components
Performance
BAR
SBS
BSCE
mDice ↑
mIoU ↑
HD95 ↓
Tumor Dice ↑
SegResNet
–
–
–
60.21 ± 6.84
51.76 ± 6.56
190.03 ± 40.24
73.66 ± 12.50
√
–
–
72.12 ± 9.09
63.99 ± 10.53
166.50 ± 38.70
84.34 ± 8.84
√
√
–
74.13 ± 8.33
66.86 ± 9.34
152.87 ± 51.31
86.54 ± 10.15
√
√
√
74.97 ± 7.90
67.55 ± 9.30
133.96 ± 37.01
87.76 ± 7.08
Table 5: Ablation study of BAR, SBS, and BSCE on CNN and Transformer backbones.
Figure 5: Intermediate-response visualization of HyBSD. Top: BSCE, including the pseudo-RGB image, ground truth, normalized raw spectral-difference response, and normalized boundary modulation weight. Bottom: boundary-aware refinement, including the pseudo-RGB image, ground truth, and WT-class probability maps before and after refinement.
Medical image benchmarks compare AI methods on curated clinical images, tasks, and evaluation protocols to measure accuracy, robustness, and clinical usefulness.
Many works have been done on salient object detection using supervised or unsupervised approaches on colour images. Recently, a few studies demonstrated that efficient salient object detection can also be implemented by using spectral features in visible spectrum of hyperspectral images from natural scenes. However, these models on hyperspectral salient object detection were tested with a very few number of data selected from various online public dataset, which are not specifically created for object detection purposes. Therefore, here, we aim to contribute to the field by releasing a hyperspectral salient object detection dataset with a collection of 60 hyperspectral images with their respective ground-truth binary images and representative rendered colour images (sRGB). We took several aspects in consideration during the data collection such as variation in object size, number of objects, foreground-background contrast, object position on the image, and etc. Then, we prepared ground truth binary images for each hyperspectral data, where salient objects are labelled on the images. Finally, we did performance evaluation using Area Under Curve (AUC) metric on some existing hyperspectral saliency detection models in literature. The dataset is publicly available on our GitHub repository and Hugging Face dataset hub. Repository: https://github.com/nevrez/HS-SOD; (Old original repository https://github.com/gistairc/HS-SOD) Dataset: https://huggingface.co/datasets/gsvrg/HS-SOD.
Nevrez Imamoglu, Yu Oishi, Xiaoqiang Zhang +4
Artificial Intelligence Research Center, National Institute of Advanced Industrial Science and Technology, Tokyo, Japan · School of Information Technology, Jiangxi University of Finance and Economics, Nanchang, China
Hyperspectral Imaging (HSI) is a promising modality for intraoperative assessment of resection margins in Breast-Conserving Surgery (BCS), but its clinical translation requires aligning the inherently 2D spectral information onto the 3D shape of the excised tissue so that suspicious regions can be precisely localized for targeted follow-up. We present a fully automated, calibration-free pipeline that produces a 3D hyperspectral point cloud of an ex-vivo lumpectomy specimen from a set of consumer-camera RGB images and a single top-down HSI acquisition. The 3D geometry is reconstructed with a deep-learning Structure-from-Motion backbone, stabilized in a metric reference frame by a custom bundle adjustment that enforces consistency on the corners of four ArUco markers placed around the specimen. The HSI cube is then registered to the reconstruction without recovering the HSI camera pose: the markers, visible in both modalities, define 16 corner correspondences that drive a planar homography, and 3D coordinates are recovered by lookup on an orthographically rendered depth map. Evaluated on two ex-vivo lumpectomy specimens, the pipeline achieves a median 3D registration error below 1 mm and a 2D reprojection error below 0.02 mm, with a total per-specimen processing time under 4 minutes on accelerated hardware. These results support the feasibility of integrating HSI-guided spatial localization into intraoperative margin assessment workflows for breast-conserving surgery.
Anna Bicchi, Alberto Rota, Leonardo Passoni +10
Authors are with the Department of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, Italy · Authors are with the Department of Physics, Politecnico di Milano, Milan, Italy
Quantifying wound tissue composition is essential for monitoring chronic ulcer progression and guiding treatment decisions. However, pixel-level annotations are costly, and multi-tissue wound datasets remain scarce, particularly for neglected diseases such as leprosy. We introduce LUTSeg, a longitudinal chronic ulcer dataset comprising 141 images from 39 patients with wound masks and five tissue categories annotated by five expert clinicians, including a multi-expert gold-standard subset for inter-rater agreement analysis. To establish an initial benchmark for LUTSeg, we further propose TiSage, a semi-supervised tissue segmentation framework that integrates multi-scale semantic priors from a frozen medical vision-language model within a teacher-student architecture. We evaluate TiSage on LUTSeg and DFUTissue, showing improvements over supervised and semi-supervised baselines in most low-label settings. Code & data: https://github.com/carlosh93/TiSage
Karen Sanchez, Carlos Hinojosa, Albert A. Ávila +5
King Abdullah University of Science and Technology (KAUST), Saudi Arabia · Subred Norte E.S.E, Hospital Simón Bolívar, Colombia · Universidad del Rosario, Bogotá, Colombia