cs.RONov 25, 2026

Calibration of Neuromusculoskeletal Models Using Differentiable Physics: Recommendations for Improving Model Accuracy

Authors: Philip Sanderink, Yingfan Zhou, Shuzhen Luo, Cheng Fang

Organizations: SDU Robotics, The Maersk Mc-Kinney Moller Institute, University of Southern Denmark, Denmark. · Department of Mechanical Engineering, Embry-Riddle Aeronautical University, United States.

Abstract

Differentiable physics has shown potential to usher in a new paradigm in human neuromusculoskeletal (NMS) model calibration. Early results from pioneering works have demonstrated that auto-differentiable NMS models can greatly reduce NMS model calibration time while achieving comparable accuracy compared to traditional calibration methods. The efficient gradient-based optimizers have enabled calibration of increasingly sophisticated human models with a large number of parameters, which seek to narrow the gap between simulation and reality. Several modules have been evaluated separately in different studies, but have never been directly compared within the same study. In this work, these modules are compared on the same differentiable upper limb model with a 3-DoF shoulder, a 2-DoF elbow, and 11 superficial and 5 deep muscles in the calibration to find an optimal pipeline for improving model accuracy. The considered modules include muscle synergy, learnable bone parameters, optimizable geometry of wrap objects, and constraint torque of the differentiable arm model. To evaluate the effect and interplay between the modules on calibration accuracy, one or more modules were used in each of 16 calibration configurations, which were compared in terms of the error between two joint torques calculated by the forward and inverse dynamics with the calibrated model on 9 distinctive testing movements across 4 subjects. Results showed that torque loss was reduced by 23.6% on average using muscle synergy extrapolation to estimate deep muscle activities, and by 10.9% on average through bone dynamic parameter optimization, which are both recommended to be incorporated in the calibration.

Figures & tables

Explore similar work

Sep 28, 2026

On the Numerical Reliability of Differentiable Physics-Based Optimization for Robotic Material Manipulation

Differentiable physics is increasingly used in robotic material manipulation for system identification, trajectory or skill optimization, demonstration generation, and robot or end-effector design. These applications depend on gradients propagated through long, contact-rich simulation rollouts. We study the numerical reliability of those gradients using two Material Point Method (MPM) system-identification benchmarks derived from elastoplastic and granular manipulation. The benchmarks provide controlled cases for three effects that also arise in broader differentiable physics-based optimization. GPU many-to-one sums whose order depends on thread scheduling changed long-horizon gradients and reversed the sign of one parameter gradient relative to a deterministic reference. Finite-difference checks became less reliable for longer rollouts because repeated-run loss variation grew much faster than the loss change produced by the tested parameter perturbations. Observation and loss definitions changed optimization behaviour and the solution preferred by an independent metric. These results motivate reproducible accumulation, finite-difference validation that compares perturbation-induced loss changes with repeated-run variation, and explicit reporting of objective construction when differentiable simulation is used for robotic optimization.
Oct 27, 2026

MyoAcross: A Framework for Scalable Individualized Musculoskeletal Simulation with a Generalist Morphology-Conditioned Policy

Musculoskeletal simulations powered by deep reinforcement learning (DRL) support human-robot interaction design and rehabilitation engineering, and they typically rely on a generic template model. However, differences in skeletal proportions and body mass alter dynamics, limiting the fidelity of generic models and the reuse of policies trained on them. Scaling individualized simulations requires a framework that connects model construction from accessible inputs with a generalist policy that transfers without fine-tuning. We present MyoAcross, which integrates skeletal-guided individual model construction, generalist morphology-conditioned policy learning, and virtual model augmentation for full-body muscle-driven control. Across 31 held-out individual models, MyoAcross achieves 99.24% completion with a 53.70 mm tracking error, compared with 8.32% completion for a baseline policy trained only on the generic model. Ablation studies show that morphology conditioning improves tracking accuracy while virtual model augmentation broadens generalization. Across input modalities, the pretrained policy demonstrates generalizability to models constructed from body shape (paired with mass), monocular images (paired with height and mass), and marker-based motion capture (paired with mass), making MyoAcross scalable. For biomechanical assessment, MyoAcross improves agreement with measured ground reaction forces and surface electromyography over the generic model on the external Gait120 dataset. These results establish MyoAcross as a practical framework for scalable individualized musculoskeletal simulation. It is suited for systematic cross-individual applications, such as exoskeleton DRL assistance policy design.
Nov 24, 2026

Fast Muscle-Driven Whole-Body Motion Tracking with a Differentiable World Model

Tracking motion capture with a whole-body musculoskeletal model means coordinating hundreds of muscles through contact, and current controllers take hours to days of GPU time to train, so every tuning decision is expensive. SuperMimic trains a tracking policy by backpropagating through the rollouts of a learned world model. We extend it to MS-Human-700 (700 muscles) and MyoFullBody (354 muscles), with MuJoCo's activation dynamics inside the world model. To make its training fast, our recipe takes the speedups developed for the Unitree G1, replaces three of their settings that fail on muscles, and adds four changes of our own: observations without muscle geometry, data collection concurrent with the updates, Beta exploration noise that keeps every excitation in [0,1][0,1], and 50 Hz control. On one RTX 5090 it trains MS-Human-700 in 6.3 minutes to the held-out return that SuperMimic's published hyperparameters reach in 3.9 hours, 37×\times sooner, and in 20 minutes to lower tracking errors than theirs after 10 hours. It trains MyoFullBody 34×\times sooner without retuning. Ablations show what is specific to muscles: a higher policy learning rate stalls half of the runs, and clipped Gaussian noise adds a tonic co-contraction that Beta noise avoids. Finally, refining the policy's actions through the world model at test time lowers the position error by a further 26% with no held-out clip failing, and reaches the same return after 5.1 instead of 6.3 minutes of training. Code, the training recipe and videos are on the project page https://muscle-supermimic.beanpow.top.