Electrocardiogram Representation Learning

Also known as ECG

Latest papers

33 papers6 papers in the last four weeks, up 50% on the four weeks before. 0.0% of all new papers.

Oct 6, 2026

MS-ECG-FM: Towards a More Universal Electrocardiogram Foundation Model for Health Monitoring using Multi-source Contrastive Learning

Electrocardiography (ECG) records the electrical activity of the heart, aiding diagnosis by detecting abnormalities in cardiac function. ECG foundation models have demonstrated promising results, but are limited by a reliance on ECG interpretation reports as their sole supervision. Because interpretation reports only capture the subset of waveform information routinely recognized by clinicians, this constrains representation learning to overlook the broader diagnostic signals present in ECG. We introduce a new ECG foundation model --- MS-ECG-FM --- that is trained through contrastive alignment to multiple distinct clinical note types, including ECG, echocardiography, radiology, and discharge reports. We evaluate MS-ECG-FM on an extended set of ECG detection benchmarks, showing that it comprehensively outperforms existing methods on the full span of conditions that ECG can detect, including in reduced-lead configurations. Different reports improve representations for different diagnostic domains, while multi-source alignment captures their complementary information and produces consistently strong representations across clinically diverse tasks.
Sep 30, 2026

Robust Transfer Learning for Paper ECG Recognition

Paper ECG recognition is challenging because real-world ECG images vary in layout, physical artifacts, and label availability. We introduce RobECG-CL, a rank-aware contrastive learning framework for robust paper ECG representation learning. Starting from standard 12-lead ECG recordings, we construct progressively degraded paper ECG views with heterogeneous layouts and train the model to balance same-recording invariance with degradation-aware ordering. Across synthetic stress tests on CODE-II and EchoNext, RobECG-CL improves robustness under severe degradation and few-shot transfer, outperforming contrastive learning baselines and surpassing the waveform-based foundation model, ECG-FM, in the 1% labeled setting. On 312 samples of hospital data with 37 labels, RobECG-CL achieves the best macro AUROC.
Sep 28, 2026

TRACE: Expert-Aligned ECG Representation Learning with Rigorous Benchmarking and Real-World Validation in Acute Cardiac Care

TRACE (Text-Reinforced Analysis of Cardio ECGs) is a multimodal electrocardiogram (ECG) representation model that learns clinically grounded signal embeddings for downstream cardiac classification. It is designed to address the limitations of existing CLIP-style training, which often struggles with noisy clinical text and fails to leverage the complementary strengths of unimodal (from ECG) and cross-modal (between ECG and matched cardiologist reports) learning. To bridge this gap, we propose a hybrid architecture that jointly learns unimodal and cross-modal representations via uncertainty-weighted multi-task learning while utilizing an LLM-based pipeline to extract high-fidelity findings from cardiologist reports. We evaluate TRACE across a spectrum of clinical urgency, establishing robust performance on public benchmarks for arrhythmia classification and structural abnormalities relative to existing unimodal and multimodal ECG models. To demonstrate real-world utility, we further validate the model on acute coronary occlusion (ACO), where the prevailing ST-elevation criteria miss 25-34% of true occlusions. Utilizing a large private ACO dataset with expert-annotated ground truth, TRACE significantly outperforms real-world clinical practice, yielding a 19.0% increase in sensitivity or a 62.6% reduction in false positive rates at the clinical baseline. This extensive evaluation confirms that TRACE delivers both strong performance on benchmark tasks and tangible clinical impact in the most acute, high-risk cardiac scenarios.
Sep 25, 2026

BeatGraph: Self-Supervised Heartbeat Graphs for Infant ECG Representations from the Home Environment

Electrocardiogram (ECG) foundation models typically tokenize the signal into fixed-length patches that ignore cardiac structure, so a patch may split a heartbeat and the number of beats in each patch shifts with heart rate. This matters most for infants, whose heart rates are higher and whose ECG differs from the adult, clinic-recorded 12-lead data these models are built on. A model for infant ECG should therefore reason about heartbeats directly rather than recover them from arbitrary patches. We propose BeatGraph, which makes the heartbeat its unit of representation, modeling each 30-second window as a graph of beats. A shared beat encoder embeds each heartbeat from its waveform and inter-beat intervals, a Transformer with positional encoding orders the beats in time, and residual graph attention layers relate every beat to every other before attention pooling yields a window embedding. We pretrain BeatGraph on our new corpus of unlabeled infant recordings by predicting masked-beat embeddings, then fine-tune it for each task. One backbone supports sleep-wake detection, infant-state classification, activity-source identification (infant- or caregiver-initiated movement), and affect recognition, improving macro-F1 over the strongest baseline on each task by 0.076 to 0.158. It also transfers across age groups, reaching 0.892 AUROC on the ZZU-pECG pediatric benchmark (ages 0 to 14), within 0.001 of the best published self-supervised ECG model, and matching that model under linear evaluation on the adult PTB-XL benchmark despite infant-only pretraining. Finally, to our knowledge, we release the first public infant ECG corpus collected in homes, classrooms, and laboratory settings with state and affect labels. It contains 3,408 hours of single-channel ECG from 143 infants aged 3 to 11 months, with unlabeled pretraining data, benchmark tasks, and subject-level splits.
Sep 24, 2026

A Hybrid CNN--State-Space--Attention Backbone with Joint-Embedding Predictive Pretraining for 12-Lead ECG Classification

Automatic 12-lead electrocardiogram (ECG) classification requires representations that jointly capture local waveform morphology, long-range temporal dynamics, and cross-lead dependencies, yet integrating these properties within a single efficient architecture remains challenging. This paper introduces a hybrid CNN-SSM-Attention backbone for 12-lead ECG classification. A convolutional stem performs early waveform tokenization and temporal reduction, mixed state-space and depthwise-convolutional blocks model temporal dynamics and local morphology, and a late self-attention stage enables global token interaction at reduced resolution. To improve transfer from unlabeled data, we further develop an ECG-oriented Joint-Embedding Predictive Pretraining (JEPA) framework. Unlike ViT-based JEPA methods that mask patch tokens before the encoder, the proposed method samples span masks at the latent temporal resolution and projects them back to the waveform domain, then predicts clean latent targets from a momentum encoder without waveform reconstruction. Experiments on CPSC2018, Chapman-Shaoxing, and PTB-XL, with pretraining on approximately 350K unlabeled CODE-15 recordings, show that the proposed backbone provides strong supervised baselines under a compact parameter budget. JEPA pretraining further improves transfer, particularly in reduced-label settings and under both full fine-tuning and LoRA-based adaptation. Code: https://github.com/yakoubbazi/Hybrid_ECG_Jepa
Sep 23, 2026

From ECG Signals to Representative-Morphology Heatmaps for Biometric Recognition

Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-morphology heatmaps, a deterministic ECG-to-image representation adapted from ECGXtractor. Within each block of ten aligned beats, the five beats closest to the block mean are averaged into a 400 by L matrix and rendered either as a conventional trace or as a dense cardiac-time-by-lead heatmap. Since both representations contain identical physiological samples, their comparison isolates the effect of rendering. We evaluate verification and closed-set identification on PTB, ECG-ID, and MIMIC-IV-ECG-DEMO. Five compact models, including ZACH-ViT, are trained from scratch, while six ImageNet-pretrained CNN and transformer backbones assess model scale and visual transfer. Heatmaps improve both FNMR operating points and both identification ranks in all 15 compact model-dataset comparisons, while EER improves in 14. Across the matched experiments, EER decreases by 9.59 percentage points and Rank-1 increases by 24.69 points on average. ConvNeXt-Tiny reaches 2.43% EER on PTB and 5.79% on ECG-ID, whereas DeiT-Base reaches 14.92% on MIMIC-DEMO. ImageNet initialization clearly benefits the two multilead datasets but has a mixed effect on ECG-ID, and performance does not increase monotonically with model size. The best heatmap systems approach the strongest signal-domain EER on PTB and ECG-ID, while DeiT-Base provides the strongest evaluated performance on MIMIC-DEMO. Lead-channel ablation further shows that useful channel combinations depend on the cohort and biometric task. Overall, representative-morphology heatmaps provide an effective image representation for ECG verification and identification.
Sep 14, 2026

On the role of the tokenizer in ECG transformer models

Tokenization determines both the physiological content presented to an ECG Transformer and the sequence over which attention operates. We compare eight tokenization strategies across Transformer, Informer, Reformer, and FEDformer on the nine-label CPSC2018 classification task. The input projection and principal backbone capacity are controlled to isolate the effect of token construction. Median-beat and HeartLang tokenization achieve mean macro-AUCs of 0.893 and 0.889 across the four backbones, compared with 0.822 and 0.824 for point-wise and patch-wise tokenization. Pooling the two physiology-aware representations yields an 8.2% relative improvement in macro-AUC. They also reduce mean sequence length from 1,250 to 158 tokens and mean peak training memory from 5.21 to 0.27 GB. The results show that aligning tokens with ECG morphology can improve both predictive performance and memory efficiency without increasing backbone capacity. The source code is available on https://github.com/LeeJarvis996/ecg_tokenizer.
Sep 4, 2026

Learning from VAE Errors to support ECG-based Differential Diagnosis of Myocardial Scar

Late Gadolinium Enhancement (LGE) on cardiac magnetic resonance is a key marker of myocardial scar, but its limited accessibility motivates routine ECG-based screening. We evaluated whether ββ-variational autoencoder (VAE)-derived ECG representations can discriminate LGE+ from LGE- cardiomyopathic patients in a local cohort of 300 subjects. We compared 32-dimensional features from the foundation ECGx.AI model with those from a shallower ββ-VAE trained on normal PTB-XL ECGs, evaluating downstream classification and Dynamic Time Warping (DTW)-based reconstruction errors. ECGx.AI reached an area under ROC of 0.686 with Random Forest, while the proposed ββ-VAE reached 0.577 with sensitivity of 0.775 with Gradient Boosting. Notably, DTW-reconstruction errors significantly differed between classes in 10 out of 12 leads according to Mann-Whitney U test and help in classification, leading to an area under ROC of 0.643 with Logistic Regression, supporting their potential as markers of scar-related ECG alterations.
Aug 31, 2026

Beat-Synchronous Tokenization for ECG Transformers

Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split heartbeat structures across token boundaries. We study beat-synchronous tokenization as a physiologically grounded alternative, comparing fixed patches with three beat-aligned strategies: resampled beats, adaptive pooled beats, and resampled beats augmented with R--R interval information. Experiments span two settings: 10-second 12-lead diagnostic classification on PTB-XL after MIMIC-IV-ECG masked pretraining, and 60-second single-lead rhythm classification on Icentia11k after patient-level contrastive pretraining. On PTB-XL, resampled beat tokens achieve the highest mean macro Area Under the ROC Curve (AUROC; 0.8945) and nearly match the best fixed-patch macro Area Under the Precision-Recall Curve (AUPRC; 0.7414), reducing average sequence length from 100 to 11.2 tokens. On Icentia11k, beat-synchronous tokenizers obtain comparable AUPRC to fixed patching with better stability across runs. These results suggest morphology-preserving beat tokenization is a compact, competitive alternative to fixed temporal patching.
Aug 27, 2026

Graph-Based Pseudo-multimodal Contrastive Learning for 12-Lead ECG Representations

12-lead electrocardiogram (ECG) is a standard, non-invasive examination widely used for diagnosing coronary artery disease, where clinical interpretation relies on comparing waveform patterns across multiple leads. However, most existing ECG analysis methods focus on single-lead signals or treat each lead independently, and typically process ECG signals as one-dimensional time-series data using CNNs or RNNs. While effective in modeling local waveform changes, such approaches have difficulty capturing inter-lead dependency and global waveform patterns essential for clinical diagnosis. To address this limitation, we propose a graph-based pseudo-multimodal contrastive learning framework called Graph-CMMC. ECG waveforms are transformed into Gramian Angular Difference Field (GADF) images to construct complementary representations of the same cardiac activity, enabling a pseudo-multimodal learning setting. Using all 12 leads, Graph-CMMC aligns waveform and GADF representations in a self-supervised manner, while a graph-based relational module is employed to model inter-lead dependency and enforce structural consistency across leads during contrastive learning. Experimental results on a multi-label coronary artery occlusion classification task demonstrate that the proposed framework achieves competitive performance compared to supervised learning methods. These results further suggest the effectiveness of using GADF as a complementary representation and incorporating explicit graph-based modeling of inter-lead dependency for learning robust 12-lead ECG representations.
Aug 21, 2026

Capturing Cardiac Cyclicity through Phase-Equivariant Self-Supervised Learning

The cyclic structure of physiological processes offers a natural prior for self-supervised representation learning, and the cardiac cycle provides a particularly well-defined setting in which to exploit it. We derive a phase-equivariant self-supervised objective and introduce Winder, a joint-embedding architecture that organises representations into phase-invariant coordinates and phase-rotating harmonic subspaces. Its transport operator is fixed and closed-form, derived from the cycle's geometry rather than learned, and adds no parameters. Evaluated on PTB-XL under a frozen linear-probe protocol, Winder attains diagnostic accuracy within the range reported by state-of-the-art self-supervised methods at a ~1 M parameter footprint, while exhibiting phase-equivariant latent geometry. These findings demonstrate that explicitly encoding cardiac-phase symmetry can preserve diagnostically useful information while yielding a latent geometry that is legible, parameter-efficient, and directly tied to a measurable physiological quantity.
Aug 13, 2026

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.
Aug 13, 2026

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.
Aug 4, 2026

LAEF: A Lead-Agnostic ECG Foundation Model Towards Point-of-Care Diagnostics

Point-of-care cardiac devices such as smartwatches and handheld ECG recorders typically capture 1--2 leads, yet existing ECG foundation models are architecturally constrained to fixed 12-lead inputs, degrading or failing under these reduced configurations. We introduce LAEF (Lead-Agnostic ECG Foundation), a 7M-parameter ECG foundation model that can natively process any lead subset without zero-padding or architectural modification. LAEF represents ECGs as variable-size spatiotemporal graphs with physiologically motivated intra- and inter-lead connectivity, processed by a Graph Attention Network that scales naturally with active lead count.Pre-trained on 9.2M 12-lead ECGs via masked node modelling with stochastic lead sampling, LAEF learns representations robust to lead configuration. Across 18 downstream datasets, LAEF is on par with specialized 12-lead baselines over 12×\times larger at full lead availability. Under direct point-of-care-oriented diagnostics (1--2 leads), it outperforms all zero-padded alternatives on 17 out of 18 datasets with with a single randomly sampled lead and on 14 out of 18 with 2 leads, with an average AUROC gain of +3.2 points. Representation analysis links this advantage to architectural lead-agnosticism, and a lead-importance study across 164 cardiovascular conditions shows population-level performance is stable across single standard input leads while still recovering established clinically lead-condition associations.
Jul 29, 2026

ECG-InterpBench: Benchmarking the Interpretability of ECG Foundation Models with Matched-Scale Sparse Autoencoders

Existing benchmarks for electrocardiogram foundation models primarily evaluate downstream predictive performance, providing limited insight into whether their internal representations can be faithfully decomposed, clinically interpreted, or reproduced across independent analyses. We introduce ECG-InterpBench, a benchmark designed to systematically evaluate the interpretability of ECG foundation-model representations. ECG-InterpBench uses sparse autoencoders as standardized measurement instruments and matches their capacity across models to enable controlled comparisons. We evaluate six frozen ECG foundation models across five standardized encoder depths, five matched dictionary widths, and three random seeds, producing a 450-cell interpretability atlas comprising 75 exactly matched six-model comparison blocks. The benchmark evaluates complementary dimensions of representation interpretability, including sparse reconstruction fidelity, single-feature accessibility and coverage of 49 clinically meaningful ECG measurements, and cross-seed feature reproducibility. The evaluation further quantifies patient-sampling uncertainty, depth- and seed-dependent variation, and sensitivity to the sparsity parameterization. The benchmark reveals that ECG foundation models exhibit distinct interpretability profiles. A matched replication on MIMIC-IV-ECG confirms that reconstruction fidelity and clinical accessibility identify different leading models. The benchmark is accompanied by executable evaluation code, standardized manifests, cell-level metrics, and reproducibility audits. ECG-InterpBench complements performance-centered ECG benchmarks by providing a capacity-controlled and reproducible framework for comparing ECG foundation models across distinct dimensions of representation interpretability.
Jul 28, 2026

CADENCE: A Cardiac Atom Dictionary for Interpretable Neural Concept Extraction from ECG Foundation Models

Foundation models for 12-lead electrocardiograms (ECGs) transfer well across clinical tasks, but the physiological knowledge encoded in their representations remains opaque. We present CADENCE, a framework that decomposes an ECG foundation model into a human-interpretable, queryable dictionary of physiological concepts. Using a BatchTopK sparse autoencoder, CADENCE factorizes Layer-6 embeddings from more than nine million ECG tokens into 8,192 sparse cardiac atoms. These atoms align better than individual dense embedding dimensions with clinical phenotypes and waveform morphology, recovering arrhythmias, conduction abnormalities, infarction and repolarization patterns, chamber and axis findings, and lead- and beat-phase-specific waveform primitives. At Layer 6, the best atoms achieve mean AUROCs of 0.88 for clinical phenotypes and 0.90 for morphology, versus 0.78 and 0.83 for the best dense dimensions. Sparse atom probes match or outperform dense probes for phenotype, morphology, and age prediction while attributing each prediction to a small set of interpretable atoms; phenotype AUROC improves from 0.93 to 0.95. Atom-space geometry recovers physiologically coherent relationships, and targeted atom ablation selectively changes frozen downstream outputs. An automated LLM pipeline generates and quantitatively validates atom descriptions by predicting held-out activations. On independent external ECG datasets, CADENCE recovers overlapping concepts and maintains consistent phenotype-prediction performance. CADENCE provides a scalable framework for discovering and auditing the physiological knowledge encoded by ECG foundation models.
Jul 13, 2026

NeuroECG: ECGFounder-Based Deep ECG Representation for EEG-Free Neurological Prognostication After Cardiac Arrest

Neurological prognostication after cardiac arrest commonly relies on electroencephalography (EEG). However, EEG demands high clinical resources. Bedside electrocardiography (ECG) is standard and low-cost. Yet, its value for predicting neurological outcomes remains underexplored. In this study, we propose NeuroECG, an ECGFounder-based deep representation framework for EEG-free auxiliary prognostication. NeuroECG adapts a pretrained ECG foundation model via task-specific fine-tuning. We implement a gradual unfreezing strategy on single-channel bedside monitoring ECG. Multiple ECG segments per patient are encoded into segment-level deep features. These embeddings are aggregated via quantile pooling (q = 0.24) and compressed using principal component analysis (PCA). Experiments on 412 ECG-available patients from the multicenter I-CARE database show that the adapted ECGFounder backbone achieves the best performance among ECG-only backbone baselines, with a test AUROC of 0.7333. We further combine the learned deep ECG representation with static clinical covariates. The proposed NeuroECG model achieves a test AUROC of 0.8077 and an AUPRC of 0.8970. These results support deep bedside ECG representations as a useful source of auxiliary prognostic information. Their integration with static clinical covariates improves prediction in an EEG-free setting. The source code is available at https://github.com/goddream66/NeuroECG
Jul 3, 2026

MorphologyFM: A Foundation Model for Morphology-Aware Representation Learning from ECG and Pulse Oximetry Waveforms

Foundation models have recently emerged as a powerful paradigm for learning transferable representations from large scale biomedical data, yet existing approaches for physiological waveforms primarily optimize reconstruction or forecasting objectives that do not explicitly preserve clinically meaningful waveform morphology. Electrocardiograms (ECGs) and pulse oximetry (SpO2) waveforms encode rich cardiovascular and hemodynamic information through their morphological structure. In this work, we introduce MorphologyFM, a multimodal foundation model pretrained on paired ECG and SpO2 waveforms from the MIMIC critical care database using a morphology aware self supervised learning objective. MorphologyFM combines morphology guided masking, cross modal representation learning, and contrastive latent alignment to learn representations that capture clinically relevant physiological structure without requiring manual annotations. We evaluate MorphologyFM across multiple downstream prediction tasks, including arrhythmia classification, hypoxemia prediction, mortality prediction, and length of stay estimation, demonstrating consistent improvements over representative self supervised learning methods, including Masked Autoencoders (MAE), contrastive learning, Barlow Twins, and Joint Embedding Predictive Architectures (JEPA). Furthermore, we show that jointly modeling ECG and SpO2 waveforms produces more transferable representations than single modality pretraining. Our results establish waveform morphology as a powerful inductive bias for self supervised physiological representation learning and introduce MorphologyFM as a general purpose foundation model for continuous physiological monitoring.
May 29, 2026

Learning Cardiac Latent Representations in Vectorcardiogram Space

Electrocardiography (ECG) is a cornerstone of cardiac assessment, making the learning of informative ECG representations fundamental to tasks ranging from disease diagnosis to clinical report generation. However, existing methods operate almost exclusively in the observable ECG signal space. In practice, the standard twelve-lead ECG represents multiple projections of the same underlying cardiac electrical activity from different spatial orientations. Therefore, representation learning in the ECG space inevitably introduces substantial redundancy, which may lead to spurious correlations and increased risk of overfitting. To address this and motivated by the Frank vectorcardiogram (VCG) model, we propose learning a unified latent representation of cardiac electrical activity directly in the VCG space. We introduce LVCG, the first general self-supervised representation learning framework designed to operate in this physically grounded latent space. By learning view-invariant latent VCG representations rather than lead-specific artifacts, VCG minimizes redundancy and improves generalization. LVCG generally outperforms ECG-space baselines across tasks, demonstrating enhanced robustness and generalization, especially in domain shift settings.
May 26, 2026

Information-theoretic Multimodal Representation Learning for Electrocardiogram Signals

Electrocardiograms (ECGs) are widely used non-invasive measurements of cardiac activity and play a central role in clinical diagnosis. Recent multimodal approaches align ECG signals with clinical reports to incorporate diagnostic semantics, but clinical reports often fail to preserve the rich physiological structure of ECG waveforms, particularly across multiple levels of abstraction ranging from coarse diagnostic categories to fine-grained morphology. To address this limitation, we formulate ECG representation learning from an information-theoretic perspective and derive a tractable objective that jointly preserves signal structure and integrates clinical semantics. Based on this principle, we propose MERIT (Multimodal ECG Representation via Information Theory), a dual-branch pretraining framework combining masked ECG modeling with ECG--text contrastive alignment. Extensive experiments on PTB-XL and additional benchmarks demonstrate consistent improvements over prior methods, including gains exceeding 33% F1 on PTB-XL All and 55% F1 on SubClass classification. In zero-shot evaluation, MERIT further improves performance by up to +2.66% +2.66\% AUC and +2.11% +2.11\% F1 on PTB-XL SubClass, while also demonstrating robustness under multiple distribution-shift settings. Moreover, leveraging the learned ECG representations for ECG-conditioned clinical text generation with large language models improves text quality across several metrics, including ROUGE and METEOR. Together, these results demonstrate that MERIT learns more informative and clinically meaningful ECG representations, particularly for fine-grained clinical applications.
May 25, 2026

A Signal-Language Foundation Model for Broad-Spectrum Cardiovascular Assessment from Routine Electrocardiography

Electrocardiography (ECG) is central to cardiovascular care, but conventional AI models are often restricted to common arrhythmias and may generalize poorly across populations or clinically subtle diseases. We developed ECG Contrastive Language-Image Pre-training (ECGCLIP), a signal-language contrastive learning framework that aligns ECG waveforms with expert diagnostic reports. ECGCLIP was pre-trained on 2,837,962 ECG studies from 1,324,856 patients and evaluated on a held-out internal test set plus nine independent external cohorts comprising about 1.5 million ECGs. Evaluation covered 89 downstream tasks, including 45 ECG diagnoses, 39 echocardiographic targets, and 5 rare cardiac diseases, using PRAUC as the primary metric. ECGCLIP consistently improved performance over random initialization and Merl-R18 baselines. On the internal test set, ECGCLIP-R34 achieved strong performance for atrial fibrillation (PRAUC 0.900) and ST-segment elevation myocardial infarction (PRAUC 0.383), with robust generalization across all external cohorts. It also improved low-prevalence and diagnostically elusive diseases, including Ebstein anomaly, constrictive pericarditis, dextrocardia, and cardiac amyloidosis, with internal PRAUC values of 0.253, 0.175, 0.121, and 0.201, respectively. ECGCLIP was data efficient, matching or exceeding full-dataset baseline performance with only 10% of training data. Feature visualization and saliency analysis suggested clinically meaningful representations aligned with established electrocardiographic criteria. These findings indicate that large-scale ECG-report contrastive pre-training can expand routine ECG interpretation beyond common arrhythmias toward broad cardiovascular assessment and opportunistic screening of echocardiographic and rare conditions.
May 17, 2026

How Do Electrocardiogram Models Scale?

While scaling laws have established a fundamental framework for foundation models in natural language processing, their applicability to electrocardiogram (ECG) models remains poorly characterized. Indeed, recent studies do not always yield consistent downstream gains as one increases the model size or pre-training dataset size of ECG models, leaving the exact roles of architectural inductive biases, pre-training paradigms, and expected improvements with size largely unanswered. In this work, we systematically investigate neural and loss-to-loss scaling laws within the ECG domain. By pre-training over 120120 models (ranging from 2020K to 200200M parameters) on the large-scale CODE dataset (2.32.3M records), we decouple the effects of model architecture (ResNet vs. Transformer) and pre-training paradigm, namely supervised learning (SL) versus self-supervised learning (SSL). We found that (i) SL models are data-bottlenecked in-distribution, whereas SSL models scale robustly across both model and data sizes; (ii) for out-of-distribution (OOD) generalization, ResNets are 1.31.3 to 2.52.5 times more parameter-efficient than Transformers, while SSL is up to 1616 times more data-efficient and achieves up to 7.67.6 times higher transfer efficiency than SL on unseen clinical tasks; (iii) across the observed scales, ResNet-based models generally achieve the lowest OOD loss, with SSL dominating on unseen clinical tasks and self-supervised Transformers overtaking at very large model sizes. Our results suggest that the path to effective ECG foundation models lies in the strategic alignment of architecture and paradigm rather than brute-force scaling.
May 12, 2026

Pretraining Strategies and Scaling for ECG Foundation Models: A Systematic Study

Specialized foundation models are beginning to emerge in various medical subdomains, but pretraining methodologies and parametric scaling with the size of the pretraining dataset are rarely assessed systematically and in a like-for-like manner. This work focuses on foundation models for electrocardiography (ECG) data, one of the most widely captured physiological time series world-wide. We present a comprehensive assessment of pretraining methodologies, covering five different contrastive and non-contrastive self-supervised learning objectives for ECG foundation models, and investigate their scaling behavior with pretraining dataset sizes up to 11M input samples, exclusively from publicly available sources. Pretraining strategy has a meaningful and consistent impact on downstream performance, with contrastive predictive coding (slightly ahead of JEPA) yielding the most transferable representations across diverse clinical tasks. Scaling pretraining data continues to yield meaningful improvements up to 11M samples for most objectives. We also compare model architectures across all pretraining methodologies and find evidence for a clear superiority of structured state space models compared to transformers and CNN models. We hypothesize that the strong inductive biases of structured state space models, rather than pretraining scale alone, are the primary driver of effective ECG representation learning, with important implications for future foundation model development in this and potentially other physiological signal domains.
Apr 24, 2026

Beyond Patient Invariance: Learning Cardiac Dynamics via Action-Conditioned JEPAs

Self-supervised learning in healthcare has largely relied on invariance-based objectives, which maximize similarity between different views of the same patient. While effective for static anatomy, this paradigm is fundamentally misaligned with clinical diagnosis, as it mathematically compels the model to suppress the transient pathological changes it is intended to detect. We propose a shift towards Action-Conditioned World Models that learn to simulate the dynamics of disease progression, or Event-Conditioned. Adapting the LeJEPA framework to physiological time-series, we define pathology not as a static label, but as a transition vector acting on a patient's latent state. By predicting the future electrophysiological state of the heart given a disease onset, our model explicitly disentangles stable anatomical features from dynamic pathological forces. Evaluated on the MIMIC-IV-ECG dataset, our approach outperforms fully supervised baselines on the critical triage task. Crucially, we demonstrate superior sample efficiency: in low-resource regimes, our world model outperforms supervised learning by over 0.05 AUROC. These results suggest that modeling biological dynamics provides a dense supervision signal that is far more robust than static classification. Source code is available at https://github.com/cljosegfer/lesaude-dynamics
Apr 13, 2026

CoRe-ECG: Advancing Self-Supervised Representation Learning for 12-Lead ECG via Contrastive and Reconstructive Synergy

Accurate interpretation of electrocardiogram (ECG) remains challenging due to the scarcity of labeled data and the high cost of expert annotation. Self-supervised learning (SSL) offers a promising solution by enabling models to learn expressive representations from unlabeled signals. Existing ECG SSL methods typically rely on either contrastive learning or reconstructive learning. However, each approach in isolation provides limited supervisory signals and suffers from additional limitations, including non-physiological distortions introduced by naive augmentations and trivial correlations across multiple leads that models may exploit as shortcuts. In this work, we propose CoRe-ECG, a unified contrastive and reconstructive pretraining paradigm that establishes a synergistic interaction between global semantic modeling and local structural learning. CoRe-ECG aligns global representations during reconstruction, enabling instance-level discriminative signals to guide local waveform recovery. To further enhance pretraining, we introduce Frequency Dynamic Augmentation (FDA) to adaptively perturb ECG signals based on their frequency-domain importance, and Spatio-Temporal Dual Masking (STDM) to break linear dependencies across leads, increasing the difficulty of reconstructive tasks. Our method achieves state-of-the-art performance across multiple downstream ECG datasets. Ablation studies further demonstrate the necessity and complementarity of each component. This approach provides a robust and physiologically meaningful representation learning framework for ECG analysis.
Apr 2, 2026

Learning ECG Image Representations via Dual Physiological-Aware Alignments

Electrocardiograms (ECGs) are among the most widely used diagnostic tools for cardiovascular diseases, and a large amount of ECG data worldwide appears only in image form. However, most existing automated ECG analysis methods rely on access to raw signal recordings, limiting their applicability in real-world and resource-constrained settings. In this paper, we present ECG-Scan, a self-supervised framework for learning clinically generalized representations from ECG images through dual physiological-aware alignments: 1) Our approach optimizes image representation learning using multimodal contrastive alignment between image and gold-standard signal-text modalities. 2) We further integrate domain knowledge via soft-lead constraints, regularizing the reconstruction process and improving signal lead inter-consistency. Extensive benchmarking across multiple datasets and downstream tasks demonstrates that our image-based model achieves superior performance compared to existing image baselines and notably narrows the gap between ECG image and signal analysis. These results highlight the potential of self-supervised image modeling to unlock large-scale legacy ECG data and broaden access to automated cardiovascular diagnostics.
Mar 27, 2026

Foundation Model for Cardiac Time Series via Masked Latent Attention

Electrocardiograms (ECGs) are among the most widely available clinical signals and play a central role in cardiovascular diagnosis. While recent foundation models (FMs) have shown promise for learning transferable ECG representations, most existing pretraining approaches treat leads as independent channels and fail to explicitly leverage their strong structural redundancy. We introduce the latent attention masked autoencoder (LAMAE) FM that directly exploits this structure by learning cross-lead connection mechanisms during self-supervised pretraining. Our approach models higher-order interactions across leads through latent attention, enabling permutation-invariant aggregation and adaptive weighting of lead-specific representations. We provide empirical evidence on the Mimic-IV-ECG database that leveraging the cross-lead connection constitutes an effective form of structural supervision, improving representation quality and transferability. Our method shows strong performance in predicting ICD-10 codes, outperforming independent-lead masked modeling and alignment-based baselines.
Mar 18, 2026

Pathology-Aware Multi-View Contrastive Learning for Patient-Independent ECG Reconstruction

Reconstructing a 12-lead electrocardiogram (ECG) from a reduced lead set is an ill-posed inverse problem due to anatomical variability. Standard deep learning methods often ignore underlying cardiac pathology losing vital morphology in precordial leads. We propose Pathology-Aware Multi-View Contrastive Learning, a framework that regularizes the latent space through a pathological manifold. Our architecture integrates high-fidelity time-domain waveforms with pathology-aware embeddings learned via supervised contrastive alignment. By maximizing mutual information between latent representations and clinical labels, the framework learns to filter anatomical "nuisance" variables. On the PTB-XL dataset, our method achieves approx. 76% reduction in RMSE compared to state-of-the-art model in patient-independent setting. Cross-dataset evaluation on the PTB Diagnostic Database confirms superior generalization, bridging the gap between hardware portability and diagnostic-grade reconstruction.
Mar 9, 2026

Echo2ECG: Enhancing ECG Representations with Cardiac Morphology from Multi-View Echos

Electrocardiography (ECG) is a low-cost, widely used modality for diagnosing electrical abnormalities like atrial fibrillation by capturing the heart's electrical activity. However, it cannot directly measure cardiac morphological phenotypes, such as left ventricular ejection fraction (LVEF), which typically require echocardiography (Echo). Predicting these phenotypes from ECG would enable early, accessible health screening. Existing self-supervised methods suffer from a representational mismatch by aligning ECGs to single-view Echos, which only capture local, spatially restricted anatomical snapshots. To address this, we propose Echo2ECG, a multimodal self-supervised learning framework that enriches ECG representations with the heart's morphological structure captured in multi-view Echos. We evaluate Echo2ECG as an ECG feature extractor on two clinically relevant tasks that fundamentally require morphological information: (1) classification of structural cardiac phenotypes across three datasets, and (2) retrieval of Echo studies with similar morphological characteristics using ECG queries. Our extracted ECG representations consistently outperform those of state-of-the-art unimodal and multimodal baselines across both tasks, despite being 18x smaller than the largest baseline. These results demonstrate that Echo2ECG is a robust, powerful ECG feature extractor. Our code is accessible at https://github.com/michelleespranita/Echo2ECG.
Mar 4, 2026

ECG-MoE: Mixture-of-Expert Electrocardiogram Foundation Model

Electrocardiography (ECG) analysis is crucial for cardiac diagnosis, yet existing foundation models often fail to capture the periodicity and diverse features required for varied clinical tasks. We propose ECG-MoE, a hybrid architecture that integrates multi-model temporal features with a cardiac period-aware expert module. Our approach uses a dual-path Mixture-of-Experts to separately model beat-level morphology and rhythm, combined with a hierarchical fusion network using LoRA for efficient inference. Evaluated on five public clinical tasks, ECG-MoE achieves state-of-the-art performance with 40% faster inference than multi-task baselines.