ground reaction force estimation
Latest papers
8 papers0 papers in the last four weeks, against 1 the four weeks before. 0.0% of all new papers.
Deep networks that estimate ground reaction forces and centers of pressure from motion-capture markers are validated within one laboratory, in a seldom-stated coordinate frame, and sometimes with trial-level splits that put the same person in the training and the test set. We measured what each practice costs, and whether such models transfer between laboratories. Three sequence models (convolutional, convolutional-recurrent, and convolutional-transformer) were evaluated on two independent datasets, locomotion (6 subjects) and occupational patient handling (10 subjects), under one pipeline, one tuning procedure, three seeds, and four protocols: trial-level split, leave-one-subject-out, pooled two-laboratory training with matched held-out subjects, and cross-laboratory transfer. At a fixed configuration, trial-level splits overstated the subject-held-out coefficient of determination by +0.040 to +0.194; on occupational data the overstatement exceeded every difference between architectures. With subjects held out, the three models reached values between 0.583 and 0.804; the leader differed between datasets, and gaps lay within subject-to-subject variability. Pooling the laboratories changed neither dataset on matched subjects. Transfer between laboratories was below chance in both directions, including the vertical force, which no in-plane rotation can affect. Leaving force targets in the plate frame while inputs were heading-aligned cost 0.57 of locomotion anteroposterior-force explained variance, enough to make that force look hardest; a Newton's-law correlation detected the mismatch before training. Split protocol and target frame changed reported accuracy more than architecture did. Learned force estimators should be validated with subjects held out, checked for frame consistency before training, and tested across laboratories before deployment claims are made.
Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury
Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset
Deep Learning-Based Estimation of Ground Reaction Forces in Parkinsonian Gait Using an Optimized Set of IMU Data
Accurate gait analysis in Parkinson's disease (PD) typically relies on laboratory-based systems to capture biomechanical data, such as ground reaction forces (GRFs). Estimating GRFs using inertial measurement units (IMUs) provides a feasible alternative. However, this approach remains challenging in pathological gait like PD due to its high variability and complexity. Moreover, existing monitoring approaches often require multiple body-mounted sensors, which limit practicality and reduce patient compliance. To date, no study has investigated the application of deep learning approaches to address this challenge. This study proposes, for the first time, a deep learning framework to estimate bilateral vertical GRFs (vGRFs) in PD using an optimized set of wearable IMUs. A hybrid CNN-BiLSTM model was trained separately on data from 61 PD patients and 65 healthy controls (HC) using 13 IMUs. The model achieved high intra-subject accuracy ( = 0.98) and strong inter-subject generalization ( = 0.93 for HC, = 0.91 for PD). Sensor configuration was found to significantly influence estimation accuracy, with optimal sensor placement varying between PD patients and HC. For PD patients, estimation accuracy dropped markedly when reducing to a single IMU. The optimal configuration for PD used four IMUs. We identified a minimal setup with only two IMUs still enabled robust estimation. This compact setup offers a practical and scalable solution. Overall, the proposed approach supports the development of wearable vGRF-based gait analysis systems for Parkinsonian gait and potentially other pathological conditions, enabling accessible clinical assessments, remote monitoring, and personalized rehabilitation.
Gravity-guided Contact Dynamics Estimation from 3D Human Motions
Ground contact forces acting on the human body, are crucial for biomechanics studies or sport performance analysis. Prior methods rely on force plates or pressure mats to collect ground contact dynamics, limiting their applicability to carefully controlled settings. A more scalable solution is to estimate the dynamics directly from motion capture data. Recent approaches only roughly estimate the ground contact dynamics from the vertical distance between the body and the ground plane, which cannot capture the complex pressure distribution of all contact points. To this end, we propose GraCE -- Gravity-guided Contact Dynamics Estimation, a novel full-body contact dynamics model for human motions using a realistic influence of body mass distribution and gravity. We use the human's center of gravity to estimate the ground contacts based on its relative distance to the human body. The applied force on each contact is estimated via the product of predicted contact probabilities and the total exterior force computed from the center of mass trajectory. We outperform related work on the GroundLink dataset for ground reaction force estimation, and on the MOYO dataset for detailed contact pressure prediction. The code is published at https://github.com/cuongle1206/GraCE
BadmintonGRF: A Multimodal Dataset and Benchmark for Markerless Ground Reaction Force Estimation in Badminton
Multimodal resources for non-periodic court sports with laboratory-grade sensing remain scarce: few publicly pair instrumented ground reaction force (GRF) with high-frame-rate multi-view video, limiting markerless load estimation in realistic training settings. BadmintonGRF records eight synchronized RGB views at ~120 FPS, four Kistler force plates, and Vicon motion capture (C3D) without hardware genlock across modalities; alignment combines human-verified events, automated quality assurance, and per-camera time offsets with uncertainty metadata. Tier 1 distributes pose, time-aligned GRF, metadata, and splits under CC BY-NC 4.0, enabling the primary benchmark without raw RGB or C3D; we report a Tier 1 task that maps 2D pose to GRF. Tier 2 provides raw RGB and C3D under controlled access for studies that require appearance or full kinematics. The public release contains 17,425 impact-segment archives in the 10-subject benchmark tree (156 instrumented trials; raw multi-view RGB alone exceeds 1 TB); benchmark loader gates retain 12,867 view-specific instances and 1,732 unique impacts after multi-view deduplication. We are not aware of prior public badminton corpora that combine this sensing layout with audited video--GRF alignment for impact-centric GRF estimation. We distribute preprocessing code, leave-one-subject-out splits, ten reference baselines, and optional late fusion (one deterministic test-time pass per instance; no test-time augmentation), with a within-trial diagnostic in the supplementary material.
Selective Correlation Based Knowledge Distillation for Ground Reaction Force Estimation
Wearable sensor-based human gait analysis holds great promise in healthcare, rehabilitation, clinical diagnosis and monitoring, and sports activities. Specifically, ground reaction force (GRF) provides essential insights into the body's interaction with the ground during movement and is typically measured using instrumented treadmills equipped with force plates. However, such equipment is expensive and restricted to laboratory environments. To enable a more portable solution, wearable insole sensors have been used to measure GRF. These sensors, however, are prone to noise and external interference, which reduces measurement accuracy. Deep learning methodologies could be adopted to address these issues, but they often require significant computing resources to achieve high accuracy, limiting their applicability for real-time analysis on portable devices. To overcome these limitations, we propose Selective Correlation Based Knowledge Distillation (SCKD) for estimating GRF from data collected by insole sensors. Our proposed method utilizes selected features considering temporal characteristics in the process of extracting correlation maps for knowledge transfer, enhancing interpretability and mitigating issues in high dimensional data processing. We demonstrate the effectiveness of the compact models generated by our distillation framework through comparison with existing methods. Various configurations of teacher-student architectures and training approaches are examined based on multiple evaluation criteria, utilizing data collected at different walking speeds and with different window sizes. Experimental results confirm that our approach outperforms existing methods in estimating GRF from wearable insole sensor data. Therefore, our approach offers a reliable and resource-efficient solution for human gait analysis.
QuietWalk: Physics-Informed Reinforcement Learning for Ground Reaction Force-Aware Humanoid Locomotion Under Diverse Footwear
Humanoid robots operating in human-centered environments (e.g., homes, hospitals, and offices) must mitigate foot--ground impact transients, as impact-induced vibration and noise degrade user experience and repeated impacts accelerate hardware wear. However, existing low-noise locomotion training often relies on kinematic proxy objectives or fragile force sensors, and footwear-induced changes in contact dynamics introduce distribution shifts that hinder policy generalization.We present QuietWalk, a physics-informed reinforcement learning framework for ground-reaction-force-aware humanoid locomotion under diverse footwear conditions. QuietWalk employs an inverse-dynamics-constrained physics-informed neural network (PINN) to estimate per-foot vertical ground reaction forces (GRFs) from proprioceptive signals, and integrates the frozen predictor into the RL training loop to penalize predicted impact forces without requiring force sensors at deployment.On a held-out real-robot dataset, enforcing inverse-dynamics consistency reduces vertical GRF prediction errors by 82%-86% compared with a purely supervised predictor and improves the coefficient of determination from 0.39/0.67 to 0.99/0.99 for the left/right feet. On hardware at 1.2 m/s (barefoot; averaged over four floor materials), QuietWalk reduces mean A-weighted noise level by 7.17 dB and peak noise level by 4.98 dB under a consistent recording setup. Cross-footwear experiments (barefoot, skate shoes, athletic sneakers, and high heels) across multiple surfaces further demonstrate robust adaptation to footwear-induced contact variations.
A Multi-Modal Dataset for Ground Reaction Force Estimation Using Consumer Wearable Sensors
This Data Descriptor presents a fully open, multi-modal dataset for estimating vertical ground reaction force (vGRF) from consumer-grade Apple Watch sensors with laboratory force plate ground truth. Ten healthy adults aged 26--41 years performed five activities: walking, jogging, running, heel drops, and step drops, while wearing two Apple Watches positioned at the left wrist and waist. The dataset contains 492 validated trials with time-aligned inertial measurement unit (IMU) recordings (approximately 100 Hz) and force plate vGRF (Force_Z, 1000 Hz). The release includes raw and processed time series, trial-level metadata, quality-control flags, and machine-readable data dictionaries. Trial-level matching manifests link recordings across modalities using stable identifiers. Of the 492 validated trials, 395 are triad-complete, containing wrist, waist, and force plate data, enabling cross-sensor analyses and reproducible model evaluation. Dataset quality is characterised through a three-phase cross-sensor plausibility and consistency framework, repeatability analysis of peak vGRF (intraclass correlation coefficient 0.871--0.990), and systematic checks of force ranges and trial completeness. Monte Carlo sensitivity analysis showed that correlation-based validation metrics were robust to single-sample timing perturbations at the IMU sampling resolution. All data are released under CC BY 4.0, with analysis scripts archived alongside the dataset and mirrored on GitHub. This resource supports reproducible research in wearable biomechanics, benchmarking of machine learning models for vGRF estimation, and investigation of sensor placement effects using widely available consumer wearables.