Ultrasound Imaging

Momentum

12 papers in the last four weeks, up 140% on the four weeks before. 0.1% of all new papers.

Jul 13Week of Sep 28

Latest papers 96

Mar 1, 2026cs.CV

Adaptive Bidirectional Task Interaction for Joint Segmentation and Classification of Breast Ultrasound

Joint lesion segmentation and tissue classification in breast ultrasound are usually trained with a shared encoder, so the two branches stop exchanging information once their decoders separate. That is exactly where boundary detail and semantic evidence are most complementary. The proposed method restores this exchange during decoding and, because its value differs between images, lets the network decide per image how much to keep. A Task Interaction Module (TIM) at each of four decoder levels passes pooled boundary context into the classification representation and modulates decoder channels with class-conditioned priors. An Adaptive Interaction Weighting (AIW) unit then blends interacted and original features with a coefficient computed for each image and level. On BUSI the model reaches 74.19% IoU and 90.60% accuracy, and on BUSI-WHU 86.40% IoU and 95.00% accuracy, ahead of encoder-sharing multi-task, transformer segmentation and decoder-interaction baselines evaluated under the same protocol. The ablation shows that multi-scale context and cross-task exchange are not independent: applied separately they contribute 4.00 points of IoU in total, applied together 6.76. Adding the adaptive blend to task interaction alone raises AUC from 94.41% to 97.31%, indicating that the blend acts primarily on the classification branch. Code: https://github.com/C-loud-Nine/Adaptive-Task-Interaction-BUS.
Feb 22, 2026cs.CV

US-JEPA: A Joint Embedding Predictive Architecture for Ultrasound

Ultrasound (US) imaging poses unique challenges for representation learning due to its inherently noisy acquisition process. The low signal-to-noise ratio and stochastic speckle patterns hinder standard self-supervised learning methods relying on a pixel-level reconstruction objective. Joint-Embedding Predictive Architectures (JEPAs) address this drawback by predicting masked latent representations rather than raw pixels. However, standard approaches depend on hyperparameter-brittle and computationally expensive online teachers updated via exponential moving average. We propose US-JEPA, a self-supervised framework that adopts the Static-teacher Asymmetric Latent Training (SALT) objective. By using a frozen, domain-specific teacher to provide stable latent targets, US-JEPA decouples student-teacher optimization and pushes the student to expand upon the semantic priors of the teacher. In addition, we provide the first rigorous comparison of all publicly available state-of-the-art ultrasound foundation models on UltraBench, a public dataset benchmark spanning multiple organs and pathological conditions. Under linear probing for diverse classification tasks, US-JEPA achieves performance competitive with or superior to domain-specific and universal vision foundation model baselines. Our results demonstrate that masked latent prediction provides a stable and efficient path toward robust ultrasound representations.
Dec 6, 2025cs.AI

Echo-CoPilot: A Multiple-Perspective Agentic Framework for Reliable Echocardiography Interpretation

Echocardiography interpretation requires integrating multi-view temporal evidence with quantitative measurements and guideline-grounded reasoning, yet existing foundation-model pipelines largely solve isolated subtasks and fail when tool outputs are noisy or values fall near clinical cutoffs. We propose Echo-CoPilot, an end-to-end agentic framework that combines a multi-perspective workflow with knowledge-graph-guided measurement selection. Echo-CoPilot runs three independent ReAct-style agents, structural, pathological, and quantitative, that invoke specialized echocardiography tools to extract parameters while querying EchoKG to determine which measurements are required for the clinical question and which should be avoided. A self-contrast language model then compares the evidence-grounded perspectives, generates a discrepancy checklist, and re-queries EchoKG to apply the appropriate guideline thresholds and resolve conflicts, reducing hallucinated measurement selection and borderline flip-flops. On MIMICEchoQA, Echo-CoPilot provides higher accuracy compared to SOTA baselines and, under a stochasticity stress test, achieves higher reliability through more consistent conclusions and fewer answer changes across repeated runs. Our code is publicly available at https://github.com/moeinheidari7829/Echo-CoPilot.
Mar 21, 2025eess.IV

Echo-E3^3Net: Efficient Endocardial Spatio-Temporal Network for Ejection Fraction Estimation

Left ventricular ejection fraction (LVEF) is a primary marker of cardiac function. However, routine estimation from endocardial measurements requires manual delineation at end-diastole (ED) and end-systole (ES), a process that is time-consuming and subject to inter-observer variability. Reliable automation is especially valuable for point-of-care ultrasound (POCUS), where computational resources are limited and acquisition quality varies. We propose Echo-E3^3Net, an anatomy-guided spatio-temporal network that explicitly embeds cardiac anatomy into LVEF prediction. A dual-phase Endocardial Border Detector (E2^2CBD) uses phase-specific cross-attention to localize ED/ES endocardial landmarks and produce phase-aware landmark embeddings, while an Endocardial Feature Aggregator (E2^2FA) fuses these embeddings with global statistical descriptors of deep feature maps to refine EF regression. Training is guided by a lightweight geometric loss that uses ED and ES endocardial landmarks to regularize EF prediction. On EchoNet-Dynamic and a PSAX subset of EchoNet-Pediatric, Echo-E3^3Net attains competitive performance using only 1.55M parameters and 8.05 GFLOPs, an order-of-magnitude compute reduction versus recent baselines, supporting real-time deployment. Our code is publicly available at https://github.com/moeinheidari7829/Echo-E3Net.
Nov 14, 2023eess.IV

Performance of Machine Learning Classification in Sonomammogram Images using BI-RADS

This research aims to investigate the classification accuracy of various state-of-the-art image classification models across different categories of breast ultrasound images, as defined by the Breast Imaging Reporting and Data System (BI-RADS). To achieve this, we used 2,945 sonomammogram images for training and 936 images for validation, with the source cohort reported as comprising 1,540 patients. In order to conduct a thorough analysis, we employed six advanced classification architecture families, including VGG19 \cite{simonyan2014very}, ResNet50 \cite{he2016deep}, GoogleNet \cite{szegedy2015going}, ConvNeXt \cite{liu2022convnet}, EfficientNet \cite{tan2019efficientnet}, and Vision Transformers (ViT) \cite{dosovitskiy2020image}, instead of traditional machine learning models. We evaluate models in three different settings: full fine-tuning, linear evaluation and training from scratch. Our findings demonstrate the effectiveness and capability of our Computer-Aided Diagnosis (CAD) system, with a remarkable accuracy of 76.39% and an F1 score of 67.94% in the full fine-tuning setting. Our findings indicate the potential for enhanced diagnostic accuracy in the field of breast imaging, providing a solid foundation for future endeavors aiming to improve the precision and reliability of CAD systems in medical imaging.
Date pendingcs.CV

Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits

Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: https://github.com/BonniciJ/OrbitalEcho/