eess.IVJan 19, 2026

Pixelwise Uncertainty Quantification of Accelerated MRI Reconstruction

Authors: Ilias I. GiannakopoulosLokesh B Gautham MuthukumarYvonne W. LuiRiccardo Lattanzi

Organizations: Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, NYU Grossman School of Medicine, 10016, New York, NY, United States of America · Courant Institute of Mathematical Sciences, NYU, 10012, New York, NY, United States of America · Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, NYU Grossman School of Medicine, 10016, New York, NY, United States of America

Abstract

Parallel imaging techniques reduce magnetic resonance imaging (MRI) scan time but image quality degrades as the acceleration factor increases. In clinical practice, conservative acceleration factors are chosen because no mechanism exists to automatically assess the diagnostic quality of undersampled reconstructions. This work introduces a general framework for pixel-wise uncertainty quantification in parallel MRI reconstructions, enabling automatic identification of unreliable regions without access to any ground-truth reference image. Our method integrates conformal quantile regression with image reconstruction methods to estimate statistically rigorous pixel-wise uncertainty intervals. We trained and evaluated our model on Cartesian undersampled brain and knee data obtained from the fastMRI dataset using acceleration factors ranging from 2 to 10. An end-to-end Variational Network was used for image reconstruction. Quantitative experiments demonstrate strong agreement between predicted uncertainty maps and true reconstruction error. Using our method, the corresponding Pearson correlation coefficient was higher than 90% at acceleration levels at and above four-fold; whereas it dropped to less than 70% when the uncertainty was computed using a simpler a heuristic notion (magnitude of the residual). Qualitative examples further show the uncertainty maps based on quantile regression capture the magnitude and spatial distribution of reconstruction errors across acceleration factors, with regions of elevated uncertainty aligning with pathologies and artifacts. The proposed framework enables evaluation of reconstruction quality without access to fully-sampled ground-truth reference images. It represents a step toward adaptive MRI acquisition protocols that may be able to dynamically balance scan time and diagnostic reliability.

Explore similar work

Jun 15, 2026cs.CV

Trustworthy MRI Reconstruction via Bayesian Uncertainty Quantification with Sparsity Prior Models

We propose a novel Bayesian framework for joint image reconstruction and uncertainty quantification from compressed sensing magnetic resonance imaging data. The problem is formulated as a linear inverse problem, where prior distributions are assigned to the unknown image parameters. Specifically, the image is assumed to be sparse in a given transform domain. We develop a general framework applicable to any sparsifying transform and demonstrate its performance using (1) a total variation transform based on image spatial gradients and (2) a wavelet-domain transform. Bayesian inference is performed using a split-and-augmented Gibbs sampler, while the resulting non-differentiable conditional distributions are efficiently sampled using a proximal Markov chain Monte Carlo method. The proposed algorithms are validated on both single-coil and multi-coil datasets using various k-space sampling patterns and acceleration factors. The results demonstrate that the proposed Bayesian methods consistently outperform their optimisation-based counterparts in image reconstruction while providing uncertainty estimates for the reconstructed images. Furthermore, the estimated uncertainty maps show a strong correlation with the true reconstruction errors and substantially outperformed deep learning-based uncertainty estimation methods.
Ahmed Karam Eldaly, Matteo Figini, Daniel C. Alexander
Jul 2, 2026eess.IV

Self-Auditing Residual Drifting for Pathology-Preserving Accelerated Knee MRI

Accelerated magnetic resonance imaging reduces acquisition time, but reconstruction from undersampled k-space can blur diagnostically relevant structures or introduce failures that are not captured by global image metrics. We propose SA-RDM-DC, a Self-Auditing Residual generative Drifting Model with Data Consistency for accelerated knee MRI. The method adapts the newly proposed generative drifting paradigm to accelerated MRI by training a physics-conditioned drift field from the zero-filled reconstruction toward the fully sampled residual correction. It predicts image- and missing-k-space residual corrections, enforces data consistency with acquired k-space, uses frequency-aware and residual drifting supervision to recover fine detail, and produces dense error maps and slice-level risk scores in the same inference pass. We evaluate SA-RDM-DC on multi-coil fastMRI knee data at acceleration factors of 4, 8, and 12, with fastMRI+ pathology annotations for region-level and classifier-based task preservation, and on SKM-TEA for zero-shot and fine-tuned protocol-shift evaluation. Compared with zero-filled reconstruction, UNet-image-SENSE, DC-UNet, Score-Diffusion, ELF-Diff, SENSE-VarNet, and MoDL baselines, SA-RDM-DC achieves the highest SSIM across fastMRI acceleration factors while retaining subsecond per-slice inference and avoiding the long sampling time of iterative diffusion baselines. In pathology-aware analysis, SA-RDM-DC preserves lesion-region structural fidelity and reduces meniscus prediction instability. Its self-auditing scores strongly identify high-error reconstructions on fastMRI and partially transfer as a selective-review signal under SKM-TEA protocol shift. These results support reconstruction evaluation that jointly considers image fidelity, pathology preservation, runtime, and case-specific reliability.
Qing Lyu, Jianxu Wang, Mohammad Kawas +2
Jun 13, 2026cs.CV

Variational Network with Wavelet-based UNET in Accelerated MRI Reconstruction from Under Sampled K-space Data

Fully sampled MRI requires dense k-space acquisition, leading to long scan times, reduced clinical throughput, and increased sensitivity to patient motion. Accelerated MRI addresses this by acquiring undersampled k-space data and reconstructing the missing information computationally. However, reconstruction from undersampled measurements is highly ill-posed and can introduce aliasing artifacts, noise amplification, and loss of anatomical detail. Although conventional parallel imaging and compressed sensing methods mitigate these issues, and deep learning methods have further improved reconstruction quality, preserving high-frequency structures under aggressive undersampling remains challenging. In this work, we propose a Variational Network with a Wavelet-based U-Net (W-UNet) for accelerated MRI reconstruction. The framework combines physics-guided iterative reconstruction with learnable multi-scale frequency representations. Standard pooling operations are replaced with Discrete Wavelet Transform and Inverse Wavelet Transform modules, enabling lossless downsampling while preserving low-frequency structure and high-frequency edge details. Integrated into the refinement and sensitivity map estimation stages, the proposed design improves artifact suppression, feature preservation, and reconstruction fidelity in both single-coil and multi-coil settings. Experiments on fastMRI knee and M4Raw brain datasets show state-of-the-art performance. Ablation studies further confirm the effectiveness of wavelet-based feature decomposition for accelerated MRI reconstruction.
Yasir Arafat Prodhan, Shaikh Anowarul Fattah