Artificial Intelligence for Detecting Fetal Orofacial Clefts and Advancing Medical Education

Authors: Yuanji Zhang, Yuhao Huang, Haoran Dou, Xiliang Zhu, Chen Ling, Zhong Yang, Lianying Liang, Jiuping Li, 

Organizations: National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen 518060, China. · Medical Ultrasound Image Computing (MUSIC) Laboratory, Shenzhen University, Shenzhen 518060, China. · Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen 518060, China. · Shenzhen Luohu People’s Hospital, Shenzhen 518001, China. · 

Abstract

Orofacial clefts are among the most common congenital craniofacial abnormalities, yet accurate prenatal detection remains challenging due to the scarcity of experienced specialists and the relative rarity of the condition. Early and reliable diagnosis is essential to enable timely clinical intervention and reduce associated morbidity. Here we show that an artificial intelligence system, trained on over 45,139 ultrasound images from 9,215 fetuses across 22 hospitals, can diagnose fetal orofacial clefts with sensitivity and specificity exceeding 93% and 95% respectively, matching the performance of senior radiologists and substantially outperforming junior radiologists. When used as a medical copilot, the system raises junior radiologists' sensitivity by more than 6%. Beyond direct diagnostic assistance, the system also accelerates the development of clinical expertise. A pilot study involving 24 radiologists and trainees demonstrated that the model can improve the expertise development for rare conditions. This dual-purpose approach offers a scalable solution for improving both diagnostic accuracy and specialist training in settings where experienced radiologists are scarce.

Figures & tables

Explore similar work

Jun 9, 2026

FADA: Accessible fetal ultrasound interpretation and annotation with a selectively distilled unified vision-language model

A global shortage of trained sonographers limits prenatal ultrasound screening in low- and middle-income countries, where over half of pregnant women receive no skilled sonography. Current deep learning approaches address detection, segmentation, or classification in isolation, each demanding a separate model and expert-specified labels at inference. We present FADA, a unified vision-language model built on Qwen3.5-VL that performs clinical interpretation, classification, detection, and segmentation through a single interpretation-first pipeline without external labels. FADA distills knowledge from four domain-specific foundation models (FetalCLIP, UltraSAM, USF-MAE, UltraFedFM) via offline pre-computed feature caching. Selective distillation, which applies feature alignment only to annotation tasks while interpretation relies on standard fine-tuning, consistently outperforms full distillation across most evaluation axes. The recommended variant, FADA-SKD, achieves 0.8820 mean Dice for segmentation, 0.7671 [email protected] for detection, and 100% structured interpretation compliance. Expert sonographer validation across 237 images confirms clinically acceptable outputs in both autonomous and human-in-the-loop modes, with 73.5% of interpretations scoring perfectly under clinician guidance. The system is trainable on a single consumer GPU and deployable without cloud connectivity. We validate edge deployment by running the compressed 0.8B model on a commodity smartphone (Qualcomm Snapdragon 7 Gen 1, 12 GB RAM) using llama.cpp with GGUF quantization, completing the full 5-phase pipeline in approximately 60 seconds entirely offline. This establishes a practical pathway for integrating AI-assisted fetal assessment with portable ultrasound devices, directly addressing diagnostic access gaps in resource-constrained settings. Code, models, and data are available at https://github.com/mahmoodphd/FADA.
Jul 15, 2026

AnomExpert: Identifying and Selecting Anatomical Planes for Prenatal Ultrasound Anomaly Diagnosis

Life-limiting congenital anomalies require accurate prenatal diagnosis for appropriate clinical decision-making. Prenatal ultrasound (US) examinations involve multiple anatomical planes, and diagnosis depends on identifying anatomical planes and selecting diagnostically relevant planes for each anomaly. Existing automated methods either rely on plane-level annotations or aggregate heterogeneous images without explicitly modeling these diagnostic capabilities. We propose AnomExpert, a prototype-driven framework for prenatal US anomaly diagnosis using only case-level supervision. AnomExpert introduces learnable plane prototypes to organize unordered images into latent representations corresponding to anatomical planes without requiring plane annotations. A disease-aware sparse selection mechanism further selects diagnostically relevant planes for each anomaly. Experiments on a multi-center dataset of 3,654 cases show that AnomExpert consistently outperforms nine representative multi-instance learning methods. Using a ViT-small backbone, it achieves 86.9% accuracy and 84.2% F1-score while maintaining parameter efficiency. These findings indicate that modeling anatomical plane identification and disease-specific plane selection improves weakly supervised multi-plane prenatal US anomaly classification. The code is available at https://github.com/TIanCat/AnomExpert.
Aug 5, 2026

FUSEP: A Multi-Center Benchmark for Diverse Tasks in Early Pregnancy Fetal Ultrasound Screening

A large number of infants with congenital anomalies are born each year globally, especially in areas with underdeveloped medical resources. Currently, fetal ultrasound screening is the most common modality for early pregnancy anatomy detection. This modality can detect anomalies earlier and provide opportune treatment advice. However, the lack of an ultrasound dataset on early fetal gestation has slowed down the development of automated assisted diagnosis. In this work, we present a benchmark dataset for Fetal Ultrasound Screening in Early Pregnancy to facilitate intelligent ultrasound examination and assisted diagnosis called FUSEP. Our dataset consists of two ultrasound views recommended by the international guideline, i.e., Crown-rump Length (CRL) and Nuchal Translucency (NT) views in three hospitals, totaling 4,017 ultrasound images, with 45,820 box-level expert-level annotations. Our dataset and baseline present the following three contributions: 1) Our medical experts annotated a total of 14 key anatomical structures in two views using a box-level format; 2) Our data is collected extensively from different sonographers, devices, scanning angles, hospitals, etc; 3) We report the performance of the semi-supervised learning, fully supervised learning, unsupervised domain adaptation (UDA), and source-free UDA in ultrasound images multi-object detection. To the best of our knowledge, this is the first publicly available dataset and benchmark for fetal early pregnancy ultrasound screening. We believe that FUSEP and benchmark can contribute to the medical community in the development of multiple tasks such as standard plane recognition, quality control on ultrasound images, automated assisted diagnostics in early fetal pregnancy, medical multi-object detection, domain adaptation for object detection, etc.