cs.CVMar 8, 2026

DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising

Authors: Yinchi Zhou, Liang Guo, Huidong Xie, Yuexi Du, Ashley Wang, Menghua Xia, Tian Yu, Ramesh Fazzone-Chettiar, +9 more

Organizations: Department of Biomedical Engineering, Yale University, New Haven, CT, USA · Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA · Department of Medicine (Cardiology), Yale School of Medicine, New Haven, CT, USA · Siemens Medical Solutions USA, Inc., Knoxville, TN, USA · Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

Abstract

Rb-82 dynamic cardiac PET imaging is widely used for the clinical diagnosis of coronary artery disease (CAD), but its short half-life results in high noise levels that degrade dynamic frame quality and parametric imaging. The lack of paired clean-noisy training data, rapid tracer kinetics, and frame-dependent noise variations further limit the effectiveness of existing deep learning denoising methods. We propose DECADE (A Temporally-Consistent Unsupervised Diffusion model for Enhanced Rb-82 CArdiac PET DEnoising), an unsupervised diffusion framework that generalizes across early- to late-phase dynamic frames. DECADE incorporates temporal consistency during both training and iterative sampling, using noisy frames as guidance to preserve quantitative accuracy. The method was trained and evaluated on datasets acquired from Siemens Vision 450 and Siemens Biograph Vision Quadra scanners. On the Vision 450 dataset, DECADE consistently produced high-quality dynamic and parametric images with reduced noise while preserving myocardial blood flow (MBF) and myocardial flow reserve (MFR). On the Quadra dataset, using 15%-count images as input and full-count images as reference, DECADE outperformed UNet-based and other diffusion models in image quality and K1/MBF quantification. The proposed framework enables effective unsupervised denoising of Rb-82 dynamic cardiac PET without paired training data, supporting clearer visualization while maintaining quantitative integrity.

Figures & tables

Explore similar work

Jul 3, 2026

Piecewise Dynamic Diffusion Regularization for Reconstruction of Cardiac Cine MRI

Real-time cardiac cine MRI enables visualization of the beating heart during free breathing, but severe undersampling and motion make reconstruction highly challenging. A central challenge for reconstruction is incorporating powerful priors of cardiac anatomy while remaining computationally efficient. We propose Piecewise Dynamic Diffusion Regularization (PDDR), a reconstruction method that integrates a spatiotemporal diffusion model as a generative prior within a variational reconstruction framework for cine MRI. The model employs dedicated spatial layers to encode anatomical structure and temporal layers to capture cardiac motion learned from gated cine data. PDDR leverages the dynamic prior in a piecewise manner, enabling the efficient use of spatiotemporal diffusion models for processing of long real-time sequences. Experiments on retrospectively accelerated and prospective real-time cine MRI demonstrate that PDDR outperforms classical, unsupervised, and diffusion-based methods, delivering high-quality reconstructions with substantially reduced computation time compared to state-of-the-art baselines. These results highlight PDDR as a practical and scalable solution for free-breathing, real-time cardiac MRI. Code is available at https://github.com/MLI-lab/pddr.
Sep 24, 2026

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac T2T2 and T1ρT1ρ MRI

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis T2T2-weighted and T1ρT1ρ-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of T2T2 and T1ρT1ρ. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.
Mar 1, 2026

Flow Matching-enabled Test-Time Refinement for Unsupervised Cardiac MR Registration

Diffusion-based unsupervised image registration has been explored for cardiac cine MR, but expensive multi-step inference limits practical use. We propose FlowReg, a flow-matching framework in displacement field space that achieves strong registration in as few as two steps and supports further refinement with more steps. FlowReg uses warmup-reflow training: a single-step network first acts as a teacher, then a student learns to refine from arbitrary intermediate states, removing the need for a pre-trained model as in existing methods. An Initial Guess strategy feeds back the model prediction as the next starting point, improving refinement from step two onward. On ACDC and MM2 across six tasks (including cross-dataset generalization), FlowReg outperforms the state of the art on five tasks (+0.6% mean Dice score on average), with the largest gain in the left ventricle (+1.09%), and reduces LVEF estimation error on all six tasks (-2.58 percentage points), using only 0.7% extra parameters and no segmentation labels. Code is available at https://github.com/mathpluscode/FlowReg.