cs.CVMar 8, 2026

DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising

Authors: Yinchi Zhou, Liang Guo, Huidong Xie, Yuexi Du, Ashley Wang, Menghua Xia, Tian Yu, Ramesh Fazzone-Chettiar, +9 more

Organizations: Department of Biomedical Engineering, Yale University, New Haven, CT, USA · Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA · Department of Medicine (Cardiology), Yale School of Medicine, New Haven, CT, USA · Siemens Medical Solutions USA, Inc., Knoxville, TN, USA · Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

Abstract

Rb-82 dynamic cardiac PET imaging is widely used for the clinical diagnosis of coronary artery disease (CAD), but its short half-life results in high noise levels that degrade dynamic frame quality and parametric imaging. The lack of paired clean-noisy training data, rapid tracer kinetics, and frame-dependent noise variations further limit the effectiveness of existing deep learning denoising methods. We propose DECADE (A Temporally-Consistent Unsupervised Diffusion model for Enhanced Rb-82 CArdiac PET DEnoising), an unsupervised diffusion framework that generalizes across early- to late-phase dynamic frames. DECADE incorporates temporal consistency during both training and iterative sampling, using noisy frames as guidance to preserve quantitative accuracy. The method was trained and evaluated on datasets acquired from Siemens Vision 450 and Siemens Biograph Vision Quadra scanners. On the Vision 450 dataset, DECADE consistently produced high-quality dynamic and parametric images with reduced noise while preserving myocardial blood flow (MBF) and myocardial flow reserve (MFR). On the Quadra dataset, using 15%-count images as input and full-count images as reference, DECADE outperformed UNet-based and other diffusion models in image quality and K1/MBF quantification. The proposed framework enables effective unsupervised denoising of Rb-82 dynamic cardiac PET without paired training data, supporting clearer visualization while maintaining quantitative integrity.

Figures & tables

Explore similar work

CardsList
  1. Piecewise Dynamic Diffusion Regularization for Reconstruction of Cardiac Cine MRI

    Jul 3, 2026Florian Fürnrohr, Reinhard HeckelImage ReconstructionAccelerated MRI Reconstruction

  2. Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac T2T2 and T1ρT1ρ MRI

    Sep 24, 2026Nicholas A. Jacobs, Jason Mendes, Ravi Ranjan +2Self-Supervised Image DenoisingMagnetic Resonance Imaging

  3. Flow Matching-enabled Test-Time Refinement for Unsupervised Cardiac MR Registration

    Mar 1, 2026Yunguan Fu, Wenjia Bai, Wen Yan +3Medical Image RegistrationDeformable Image Registration