Large Language Models (LLMs) have demonstrated impressive capabilities across various specialist domains and have been integrated into high-stakes areas such as medicine. However, as existing medical-related benchmarks rarely stress-test the long-context memory, interference robustness, and safety defense required in practice. To bridge this gap, we introduce MedMT-Bench, a challenging medical multi-turn instruction following benchmark that simulates the entire diagnosis and treatment process. We construct the benchmark via scene-by-scene data synthesis refined by manual expert editing, yielding 400 test cases that are highly consistent with real-world application scenarios. Each test case has an average of 22 rounds (maximum of 52 rounds), covering 5 types of difficult instruction following issues. For evaluation, we propose an LLM-as-judge protocol with instance-level rubrics and atomic test points, validated against expert annotations with a human-LLM agreement of 91.94%. We test 17 frontier models, all of which underperform on MedMT-Bench (overall accuracy below 60.00%), with the best model reaching 59.75%. MedMT-Bench can be an essential tool for driving future research towards safer and more reliable medical AI. The benchmark is available in https://openreview.net/attachment?id=aKyBCsPOHB&name=supplementary_material
Figures & tables
Figure 1: An example of multi-patient information interference in the domain of long context memory and understanding in the pre-diagnosis stage.
Figure 2: Test examples in the remaining four multi-turn difficult dimensions.
Attributes
Number
# Categories
- LCMU
152
- RCI
41
- SCASD
63
- IC
98
- MIRI
46
Table 1: Detailed statistics for the MedMT-Bench.
Figure 3: The distribution of complex multi-turn instruction following problems.
Figure 4: Example of test points for synthesis.
Figure 5: Workflow of MedMT-Bench. The upper panel depicts the single-stage data synthesis process, which combines multi-agent conversation synthesis, verification, and manual editing to produce challenging examples targeting specific evaluation dimensions. The lower panel shows the multi-stage, scene-by-scene synthesis pipeline. Subsequent scene test cases build on the multi-turn conversations from the preceding scene and derive inputs via a portrait extraction strategy.
Consistent rate
Auto-Eval without ATP
Auto-Eval with ATP
GPT-5
40.33%
85.40%±1.2
Claude-4-Opus
39.68%
86.97%±0.8
OpenAI o3
37.98%
87.03%±1.1
Gemini-2.5-Pro
41.09%
91.94%±0.6
GPT-4o
39.91%
86.99%±1.0
GPT-4.1
40.93%
88.96%±0.8
Table 2: Consistency rate between automatic and manual evaluation with and without test points (ATP).
Human Evaluation
Model Names
LCMU
RCI
SCASD
IC
MIRI
HC
PSRO
PTRM
Avg
GPT-4o(2024-11)
33.55
21.95
34.92
22.45
47.83
34.36
24.53
23.21
31.50
GPT-4.1(2025-04)
33.55
46.34
50.79
24.49
63.04
43.64
28.3
23.21
38.75
Gemini-2.5-Pro
46.05
60.98
68.25
28.57
54.35
49.48
47.17
37.50
47.75
OpenAI o3(2025-04)
50.00
39.02
57.14
36.73
50.00
49.48
47.17
32.14
46.75
Claude4-Sonnet
57.89
46.34
52.38
48.98
56.52
54.30
50.94
51.79
53.50
Table 3: The accuracy performance (%) of the human and automatic evaluation of 7 frontier models.
Model Names
LCMU
RCI
SCASD
IC
MIRI
HC
PSRO
PTRM
Avg
Qwen3-8B-Instruct
44.44
18.42
35.71
20.27
56.52
36.31
35.85
26.42
34.39
Qwen3-32B-Instruct
55.56
21.05
40.48
24.32
69.57
44.13
45.28
30.19
41.75
Llama3.1-8B-Instruct
17.59
26.32
21.43
6.76
39.13
20.11
16.98
13.21
18.25
Llama3.1-70B-Instruct
29.63
26.32
28.57
9.46
43.48
27.37
26.42
15.09
24.91
Kimi-K2-1T-A32B
50.93
44.79
57.14
28.38
47.83
51.40
33.96
33.96
44.91
GLM-4.5-355B-A32B
44.86
36.84
47.62
28.38
56.52
43.58
39.62
32.69
40.85
Table 4: The accuracy performance (%) of the automatic evaluation of 7 open-source models on the text subset.
Figure 6: Performance comparison of 7 frontier models on different modal and 5 instruction following problems.
Figure 7: The performance distribution of 7 frontier models on the finest-grained multi-turn instruction following problems. Each bar consists of two parts: the solid part represents the performance of the text subset, and the transparent part represents the performance of the whole set after combining the image modal subset.
Appendix figures & tables13 assets
Supplementary material from the paper’s appendix.
Appendix
Figure 8: Data distribution of MedMT-Bench in different turns.
Figure 9: Data distribution of MedMT-Bench in different departments.
Model Names
LCMU
RCI
SCASD
IC
MIRI
Avg
Qwen3-8B-Instruct (w/o thinking)
41.67
13.16
35.71
21.62
60.87
33.33
Qwen3-8B-Instruct (w/ thinking)
44.44
18.42
35.71
20.27
56.52
34.39
Qwen3-32B-Instruct (w/o thinking)
41.67
13.16
47.62
14.86
78.26
34.74
Qwen3-32B-Instruct (w/ thinking)
55.56
21.05
40.48
24.32
69.57
41.75
GLM-4.5-355B-A32B (w/o thinking)
34.26
21.05
50.00
27.03
52.17
34.39
GLM-4.5-355B-A32B (w/ thinking)
44.86
36.84
47.62
28.38
56.52
40.85
Appendix
Table 5: The accuracy performance (%) of 3 open-source models in thinking and non-thinking modes on MedMT-Bench text subset.
Figure 10: Performance comparison of 3 open-source vision models on different modal and multi-turn instruction following problems.
Model Names
LCMU
RCI
SCASD
IC
MIRI
Avg
Qwen2.5-VL-7B-Instruct
22.52
12.20
26.98
12.24
39.13
21.55
Qwen2.5-VL-72B-Instruct
33.77
21.95
34.92
24.49
43.48
33.96
GLM-4.5V-106B-A12B
42.76
14.63
44.44
20.41
32.61
33.50
Appendix
Table 6: The accuracy performance (%) of 3 open-source vision models on MedMT-Bench.
Figure 11: Performance trends of several problem dimensions strongly related to long contexts averaged over all models at different turns.
Figure 12: Performance of 7 closed-source frontier models in different medical departments.
Figure 13: The performance distribution of 7 open-source models on the finest-grained multi-turn instruction following problems.
Model Names
Round1
Round2
Round3
Avg
GPT-4o(2024-11)
34.75
35.25
34.50
34.83±0.3
GPT-4.1(2025-04)
41.75
42.00
42.25
42.00±0.2
Gemini-2.5-Pro
50.50
50.75
49.50
50.25±0.5
OpenAI o3(2025-04)
48.75
49.00
48.50
48.75±0.2
Claude4-Sonnet
52.25
52.75
53.50
52.83±0.5
Claude4-Opus
54.00
54.00
53.75
53.92±0.1
Appendix
Table 7: The mean and standard deviation of three evaluations with the temperature set to 0.
Figure 14: The modified instruction structure used for automated evaluation shows that the left side changed the order of the output structure and judge requirements modules; the right side changed the order of the different sub-requirements in the judge requirements.
Model Names
tp-1.0
tp-0.5
tp-0
Avg
st-v1
st-v2
st-v3
Avg
GPT-4o(2024-11)
34.50
35.25
34.75
34.83±0.3
34.75
35.50
35.5
35.25±0.4
GPT-4.1(2025-04)
41.75
42.25
41.75
41.92±0.2
41.75
42.25
42.25
42.08±0.2
Gemini-2.5-Pro
51.50
49.50
50.50
50.50±0.8
50.50
49.00
50.75
50.08±0.8
OpenAI o3(2025-04)
48.25
49.50
48.75
48.83±0.5
48.75
47.75
49.50
48.67±0.7
Claude4-Sonnet
52.00
52.75
52.25
52.33±0.3
52.25
52.25
52.75
52.42±0.4
Claude4-Opus
54.50
53.25
54.00
53.92±0.5
54.00
53.50
54.75
54.08±0.5
Appendix
Table 8: Automated evaluation mean and standard deviation under different temperature(tp) settings and different prompt structures(st).
Model Names
Consistent rate
GPT-5-high
89.50%
Claude-4-Opus
91.25%
OpenAI o3(2025-04)
92.25%
Gemini-2.5-Pro
93.00%
GPT-4o(2024-11)
94.50%
GPT-4.1(2025-04)
91.25%
Appendix
Table 9: Automated evaluation mean and standard deviation under different temperature(tp) settings and different prompt structures(st).
Model
Temperature
Top-P
Max Tokens
All models
1
0.7
80k
Appendix
Table 10: Inference temperatures for LLMs evaluated on MedMT-Bench
Medical benchmarks are dominated by single-turn, multiple-choice clinical cases that poorly reflect real consultations. Practically, clinicians elicit evidence interactively and patient communication varies widely. We introduce MedRoundsQA, a multi-turn diagnostic benchmark derived from 1,387 board-exam cases across 17 specialties. Each case is converted into a structured 24-slot clinical record, and then instantiated as controlled doctor-patient dual-agent dialogues under varying patient personas, with the underlying clinical content held fixed. We further classify cases by difficulty using model-based uncertainty to enable easy-to-hard analysis. Evaluations of fifteen LLM doctor agents show that (i) moving from a single-turn diagnosis on the standardized records to multi-turn consultations causes large degradations of roughly 13-39 points; (ii) more turns reliably improves question relevance, but diagnostic accuracy exhibits diminishing returns and typically plateaus after 6-12 turns; and (iii) patient persona differences can shift diagnosis accuracy by about 7-8 points (lowest to highest education), highlighting equity risks that single-turn benchmarks miss.
Youssef Mohamed, Ahmed Heakl, Qinrong Cui +13
MBZUAI · Cairo University · Ain Shams University +2
Large language models (LLMs) achieve high accuracy in medical diagnosis when all clinical information is provided in a single turn, yet how they behave under multi-turn evidence accumulation closer to real clinical reasoning remains unexplored. We introduce MINT (Medical Incremental N-Turn Benchmark), a high-fidelity, multi-turn medical diagnosis benchmark comprising 1,035 cases with clinically labeled evidence shards, controlled turn granularity, and information-preserving decomposition. Through systematic evaluation of 11 LLMs on MINT, we uncover three persistent behavioral patterns that significantly impact diagnostic decisions: (1) intent to answer, models rush to answer before sufficient evidence has been observed, with over 55% of answers committed within the first two turns; (2) self-correction, incorrect-to-correct answer revisions occur at up to 10.6 times the rate of correct-to-incorrect flips, revealing a latent capacity for self-correction that premature commitment forecloses; and (3) strong lures, clinically salient information such as laboratory results trigger premature answering even when models are explicitly instructed to wait. We translate these findings into clinically actionable guidance: deferring the diagnostic question to later turns reduces premature answering and improves accuracy at the first point of commitment by up to 62.6%, while reserving salient clinical evidence for later turns prevents a catastrophic accuracy drop of up to 23.3% caused by premature commitment. Our work provides both a controlled evaluation framework and concrete recommendations for improving the reliability of LLMs in multi-turn medical diagnosis.
Jinrui Fang, Runhan Chen, Xu Yang +9
The University of Texas at Austin · New York University · The University of Texas Southwestern Medical Center +2
Large language models (LLMs) now reach expert-level scores on medical licensing exams, encouraging the assumption that high scores imply safe medical judgment while patients increasingly use them for health advice. We show this assumption is fragile: when misleading context is injected into questions that LLMs originally answer correctly, they abandon the correct answer. We call the ability to maintain correct judgment under adversarial context epistemic resilience, and introduce MedMisBench to measure it. MedMisBench contains 10,932 medical question items and 48,889 misleading context-option pairs spanning medical reasoning, agentic capability, and patient-journey evaluation. Across 11 model configurations, mean accuracy falls from 71.1% on original questions to 38.0% under focused misleading context, with 51.5% attack success. The most damaging injections are formal, rule-like fabrications: authority-framed falsehoods reach 69.5% attack success and exception-poisoning claims reach 64.1%. A 14-member clinical panel from 7 countries identified serious potential harm in 38.2% of reviewed cases. MedMisBench exposes a structural blind spot in LLM evaluation in medical settings: existing benchmarks measure what models know, but not whether they preserve correct medical judgment under misleading context.
Hongjian Zhou, Xinyu Zou, Jinge Wu +19
University of Oxford · University of Washington · University College London +1