physics.med-phApr 7, 2026

Spatiotemporal Gaussian representation-based dynamic reconstruction and motion estimation framework for time-resolved volumetric MR imaging (DREME-GSMR)

Authors: Jiacheng XieHua-Chieh ShaoCan WuRicardo OtazoJie DengMu-Han LinTsuicheng ChiuJacob Buatti+2 more

Organizations: The Advanced Imaging and Informatics for Radiation Therapy (AIRT) Laboratory · The Medical Artificial Intelligence and Automation (MAIA) Laboratory · Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA

Abstract

Time-resolved volumetric MR imaging that reconstructs a 3D MRI within sub-seconds to resolve deformable motion is essential for motion-adaptive radiotherapy. Representing patient anatomy and associated motion fields as 3D Gaussians, we developed a spatiotemporal Gaussian representation-based framework (DREME-GSMR), which enables time-resolved dynamic MRI reconstruction from a pre-treatment 3D MR scan without any prior anatomical/motion model. DREME-GSMR represents a reference MRI volume and a corresponding low-rank motion model (as motion-basis components) using 3D Gaussians, and incorporates a dual-path MLP/CNN motion encoder to estimate temporal motion coefficients of the motion model from raw k-space-derived signals. Furthermore, using the solved motion model, DREME-GSMR can infer motion coefficients directly from new online k-space data, allowing subsequent intra-treatment volumetric MR imaging and motion tracking (real-time imaging). A motion-augmentation strategy is further introduced to improve robustness to unseen motion patterns during real-time imaging. DREME-GSMR was evaluated on the XCAT digital phantom, a physical motion phantom, and MR-LINAC datasets acquired from 6 healthy volunteers and 20 patients (with independent sequential scans for cross-evaluation). DREME-GSMR reconstructs MRIs of a ~400ms temporal resolution, with an inference time of ~10ms/volume. In XCAT experiments, DREME-GSMR achieved mean(s.d.) SSIM, tumor center-of-mass-error(COME), and DSC of 0.92(0.01)/0.91(0.02), 0.50(0.15)/0.65(0.19) mm, and 0.92(0.02)/0.92(0.03) for dynamic reconstruction/real-time imaging. For the physical phantom, the mean target COME was 1.19(0.94)/1.40(1.15) mm for dynamic/real-time imaging, while for volunteers and patients, the mean liver COME for real-time imaging was 1.31(0.82) and 0.96(0.64) mm, respectively.

Explore similar work

Jun 2, 2026cs.CV

Prospective Dynamic 3D MRI Reconstruction via Latent-Space Motion Tracking from Single Measurement

Prospective reconstruction is crucial in many clinical applications such as MRI-guided radiotherapy, which demands accurate image reconstruction and fast motion estimation from currently acquired measurements. However, prospective reconstruction remains challenging due to ultra-sparse sampling and stringent latency requirements. In this work, we propose PDMR, a Prospective Dynamic 3D MRI Reconstruction framework with latent-space motion tracking. Our core idea is to learn an efficient and generalizable latent manifold of motion fields offline, enabling rapid online adaptation for prospective reconstruction. Specifically, we parameterize the deformation vector fields (DVFs) on a low-dimensional manifold, effectively reducing the search space for fast online adaptation, and employ a tri-plane representation to achieve geometry-aware and memory-efficient encoding of 3D motion. Experiments on both XCAT digital phantoms and in-house abdominal MRI datasets demonstrate that PDMR achieves high-fidelity and temporally consistent reconstruction across multiple prospective scenarios (Immediate and After-2min), outperforming state-of-the-art retrospective and online methods. Our results suggest a promising pathway toward ultra-fast, motion-aware prospective MRI reconstruction in clinical practice.
Lixuan Chen, Zhongnan Liu, Jesse Hamilton +3
May 21, 2026cs.CV

MotionDPS: Motion-Compensated 3D Brain MRI Reconstruction

Magnetic resonance imaging (MRI) is highly susceptible to patient motion due to its relatively long acquisition times and the fact that data are acquired sequentially in k-space. Even small patient movements introduce phase inconsistencies across measurements, leading to severe artifacts such as blurring, ghosting, and geometric distortions that can compromise diagnostic quality. Retrospective motion compensation remains challenging, particularly in accelerated acquisitions, due to the ill-posed nature of the joint reconstruction and motion estimation problem. In this work, we propose a unified Bayesian framework for motion-compensated 3D MRI that jointly estimates the anatomical image, rigid-body motion parameters, and coil sensitivity maps directly from motion-corrupted k-space data. Our approach integrates pretrained 3D complex-valued score-based diffusion models as expressive anatomical image priors within a physics-based forward model. Inference is performed by alternating diffusion posterior image updates with efficient proximal optimization steps for motion and coil sensitivity estimation, enabling fully unsupervised reconstruction without the need for paired motion-free training data. Experiments on simulated and real-motion brain MRI datasets demonstrate that the proposed method achieves improved image quality and motion robustness compared to state-of-the-art classical and learning-based motion correction techniques, particularly in the presence of severe motion and high acceleration.
Antonio Ortiz-Gonzalez, Erich Kobler, Lukas Schletter +1
Jul 29, 2026cs.CV

K-space Gaussian Representation for Parallel MRI

Accelerated magnetic resonance imaging (MRI) aims to recover the k-space signal from acquired measurements, where accurate estimation of missing samples is essential for high-fidelity reconstruction. Existing k-space reconstruction methods estimate missing samples through interpolation operators or structure priors defined on discrete sampling grids. Although these formulations effectively exploit local interpolation relationships and global k-space redundancy, they reconstruct only discrete frequency coefficients and therefore do not explicitly model the underlying continuous signal. To overcome this limitation, we propose K-space Gaussian Representation (KGR), the first explicit continuous representation formulated directly in the native k-space domain. Rather than estimating unknown samples on discrete grids, KGR parameterizes the continuous signal using Gabor-Gaussian primitives with shared spatial geometry, yielding a compact representation that naturally preserves inter-coil correlations. Because unconstrained continuous fitting does not necessarily satisfy the intrinsic structural properties of multi-coil signal, the estimated representation is projected onto a low-rank manifold to enforce the algebraic constraints arising from smoothly varying phase and coil redundancy. A frequency-adaptive fitting strategy accommodates the heterogeneous characteristics of different k-space regions. Comprehensive validation across multiple datasets and sampling schemes shows consistent improvements over representative reconstruction baselines in both quantitative metrics and visual quality. These results suggest that explicit continuous parameterization of native k-space provides a principled framework for integrating continuous signal modeling with structured low-rank reconstruction.
Yu Guan, Mingyu Hu, Jiale Hu +3