cs.ROMay 6, 2026

Optimal Uncertainty-Aware Calibration for the AX=YB Problem

Authors: Yanjia ChenXiangfei LiHuan ZhaoYiyuan HongGuanxiao XiaJiexin ZhangHan Ding

Abstract

This article proposes a general optimization framework for solving hand-eye calibration problem. Unlike traditional methods, an iterative algorithm based on Lie algebra that achieves approximately global optimal solutions is developed. During the optimization process, the method strictly preserves the structural constraints of the calibration parameters and enables synchronized updates between calibration parameters. Recognizing that data used in real-word hand-eye calibration often contain uncertainty, especially in over-loading and large workspace industrial robot scenarios, which can significantly degrade accuracy, and accurately modeling such uncertainty is inherently difficult, this article avoids explicit uncertainty modeling. Instead, an uncertainty metric to evaluate the relative uncertainty between data sources is introduced and used to dynamically refine the iterative process. To further enhance convergence efficiency, an effective initial solution generation method that improves overall stability and accuracy is designed. Numerical simulations and real-world experiments validate the effectiveness of the proposed approach, and in synthetic datasets, the proposed approach improves the estimation accuracy by at least 67% under high-uncertainty conditions compared with the existing methods.

Explore similar work

Apr 29, 2025cs.RO

Hydra: Marker-Free RGB-D Hand-Eye Calibration

This work presents an RGB-D imaging-based approach to marker-free hand-eye calibration using a novel implementation of the iterative closest point (ICP) algorithm with a robust point-to-plane (PTP) objective formulated on a Lie algebra. Its applicability is demonstrated through comprehensive experiments using three well known serial manipulators and two RGB-D cameras. With only three randomly chosen robot configurations, our approach achieves approximately 90% successful calibrations, demonstrating 2-3x higher convergence rates to the global optimum compared to both marker-based and marker-free baselines. We also report 2 orders of magnitude faster convergence time (0.8 +/- 0.4 s) for 9 robot configurations over other marker-free methods. Our method exhibits significantly improved accuracy (5 mm in task space) over classical approaches (7 mm in task space) whilst being marker-free. The benchmarking dataset and code are open sourced under Apache 2.0 License, and a ROS 2 integration with robot abstraction is provided to facilitate deployment.
Martin Huber, Huanyu Tian, Christopher E. Mower +4
Apr 17, 2026cs.CV

Continual Hand-Eye Calibration for Open-world Robotic Manipulation

Hand-eye calibration through visual localization is a critical capability for robotic manipulation in open-world environments. However, most deep learning-based calibration models suffer from catastrophic forgetting when adapting into unseen data amongst open-world scene changes, while simple rehearsal-based continual learning strategy cannot well mitigate this issue. To overcome this challenge, we propose a continual hand-eye calibration framework, enabling robots to adapt to sequentially encountered open-world manipulation scenes through spatially replay strategy and structure-preserving distillation. Specifically, a Spatial-Aware Replay Strategy (SARS) constructs a geometrically uniform replay buffer that ensures comprehensive coverage of each scene pose space, replacing redundant adjacent frames with maximally informative viewpoints. Meanwhile, a Structure-Preserving Dual Distillation (SPDD) is proposed to decompose localization knowledge into coarse scene layout and fine pose precision, and distills them separately to alleviate both types of forgetting during continual adaptation. As a new manipulation scene arrives, SARS provides geometrically representative replay samples from all prior scenes, and SPDD applies structured distillation on these samples to retain previously learned knowledge. After training on the new scene, SARS incorporates selected samples from the new scene into the replay buffer for future rehearsal, allowing the model to continuously accumulate multi-scene calibration capability. Experiments on multiple public datasets show significant anti scene forgetting performance, maintaining accuracy on past scenes while preserving adaptation to new scenes, confirming the effectiveness of the framework.
Fazeng Li, Gan Sun, Chenxi Liu +3
Sep 17, 2026cs.RO

OmniCalib: Target-Free, Task-Structured Self-Calibration for Humanoid Robots

Assembly, wear, and component replacement perturb the sensor extrinsics and joint zeros encoded by a humanoid CAD model. Existing procedures calibrate one sensor pair or require external fiducials. Using only robot-native motion and onboard sensing, we present OmniCalib, a target-free workflow that calibrates the full upper limbs---all 14 arm joint zeros and the extrinsics of both wrist and chest cameras---as well as lower limbs and the multi-camera head rig. Each module matches a robot-native task to a parameter block, checks observability, and writes only supported corrections to the CAD model. Our depth ICP method recovers all 14 arm joint zeros and calibrates all RGB-D camera extrinsics without any calibration target. Relative to CAD, the estimated extrinsic corrections are 10.56 mm and 1.74 degrees for the left wrist, 6.33 mm and 1.25 degrees for the right wrist, and 9.81 mm and 0.929 degrees for the chest RGB-D camera. ICP point-to-plane residual is 2.09 mm. On the same injected offsets, ICP and ArUco recover all 14 joint zeros below the 0.1-degree encoder-resolution reference. On an AGIBOT A3 Ultra humanoid, four static double-support stances recover all 12 lower-limb joint-zero offsets injected with an RMS error of 0.063 degrees. The head module combines multi-camera visual odometry with legged odometry and dynamic compensation through the live ROS transform tree. Using only planar walking, it attains a mean SO(3) error of 1.061 degrees across three sequences. The best sequence reaches 0.775 degrees, competitive with iKalibr at 0.902 degrees from rich 6-DOF excitation. Rig-relative angles repeat within 0.140 degrees. Injection recovery and held-out tests validate each observable block.
Kaixiang Lu, Haiyu Lan, Chunxiao Qiao +6