A Master-Slave Robot Manipulator for Needle-Based Teleoperation in MRI Chamber
Authors: Omar Curiel, Jing-Yuan Huang, Po-Chih Chen, Ji Ma, Qing Dai, Wenqi Zhou, David Lu, Holden H. Wu, +1 more
Abstract
We present a MR safe, master-slave robot manipulator for abdominal interventions in the MRI chamber. A human operated 2+1-DoF master controller manipulator transmits motion and force to a 2+1-DoF slave manipulator via fluid transmission. Jointly, a digital master controller provides multimodal control capability beyond common split axis or mode switchable hybrid human-digital controller configurations found in previous studies. High input impedance, low-leakage, elastomeric fluid actuators are delegated to remote angulation control. Low-friction graphite piston cylinders are delegated to needle insertion axis remote actuation given the sub-newton force transparency and sub-millimeter motion transmission over bedside fluid piping lengths. The device enables real-time MRI guided interventions allowing manual, digital, hybrid, and collaborative control modes. Collaborative tasks such as assisted tissue penetration, fault-driven virtual fixture, and motion compensation through feedback control are presented in this paper. Preliminary MR scanner results demonstrate manipulator functional viability for an in-vivo pig experiment in bedside, manual control mode configuration.
Objective: To evaluate robotic controller interfaces for interventional neuroradiology procedures in-vitro incorporating a force-sensing platform to assess safety. Methods: A custom endovascular robot, device-mimicking controller, and sensorized neurovascular phantom were developed. Ten interventional neuroradiologists (4 novices, 6 experts) performed simulated navigations using four control modalities: device-mimicking controllers with and without haptic feedback, joystick-based input, and manual navigation. Navigation time, peak vessel-wall forces, incorrect catheterisations, and prolapse events were assessed, alongside user analyses. Results: Manual navigation was fastest (mean 47.7 s) compared to haptic-on (248.7 s), haptic-off (314.7 s), and joystick (392.6 s) modalities (p<0.001). Regardless of controller type, vessel-wall forces were below the 0.70 N puncture threshold; therefore all modalities were considered safe. Joystick produced significantly more prolapse events than manual control (1.56 vs 0.13; p=0.018). Operator experience was relevant to performance: experts made fewer incorrect catheterisations than novices (0.25 vs 0.62; p=0.035) and applied less vessel-wall force (p<0.0005); these effects were sustained across controllers but accentuated when haptics were on. Users perceived haptic on and haptic off as similarly intuitive, and more intuitive than joystick (p=0.033). Conclusion: Device-mimicking robotic controllers outperform joystick interfaces on most metrics; haptic feedback shows promising but non-significant performance benefits.
Benjamin Jackson, Nikola Fischer, Harry Robershaw +16
This paper presents an immersive bilateral teleoperation framework for beyond-human-scale manipulators, combining motion/force transparency with enhanced operator embodiment through virtual reality (VR) and distributed haptic feedback. The platform integrates a full-scale industrial hydraulic manipulator, a 7-DoF haptic exoskeleton, and head-tracked visual feedback to reinforce operator agency and self-location. A force-sensorless adaptive controller incorporates an augmented human-robot dynamic model to address master-surrogate asymmetries, input nonlinearities, model uncertainties, and communication delays. Rigorous analysis establishes semi-global uniform ultimate boundedness of the closed-loop system. Extensive full-scale experiments demonstrate precise motion and force tracking with scaling up to 1:13 and 1:1000, respectively, and fixed or time-varying delays up to 150 ms. Coordinated 6-DoF pick-and-place and multi-axis contact tasks further validate system performance. A ten-participant user study supports system usability and indicates approximately 50% higher normalized embodiment scores with VR than with monitor-based feedback. These results advance intuitive, force-reflected remote manipulation at industrial scale.
The paper presents a numerical approach for the end-effector trajectory smoothing of a parallel robot designed for minimally invasive pancreatic surgery. The approach is tailored for real-time master-slave control architecture and uses a 3D space mouse for command input for velocity control. The trajectory smoothing is achieved by generating S-curves in the end-effector velocity fields, thus controlling the accelerations, which in turn reduces tissue trauma in the minimally invasive procedures. Real-time control is enabled by segmenting the S-curves based on the command inputs from the 3D space mouse. A special case is considered where the acceleration time is constant for all command inputs. Numeric results demonstrate stable transitions (without abrupt changes) in both the end-effector parameter space and in the active joints parameters, thereby validating the proposed approach. Further work aims to test the approach on an experimental model and integrate it into AI-based training modules.
Iosif Birlescu, Alexandru Pusca, Bogdan Gherman +4