cs.LGSep 27, 2026

Feedback-Robust AI for Patient Knowledge Graphs

Authors: Mohammed Sameer Syed

Organizations: Roshan AI

Abstract

Patient knowledge graphs from bedside monitoring should type their relations and state whether the data support their signs. In anesthesia and intensive care, clinicians titrate drugs and ventilation in response to the physiology, so temporal relations mix the patient's response with the clinician's policy. We introduce ClosedLoopBench: 29 relations with signs fixed by physics, pharmacology or clinical practice, on 3,442 VitalDB surgical cases (12,653 h) with negative-control action streams. When each patient's actions are replaced by another patient's, six of 12 estimators declare on average 11-18 of their 19-29 distinct relation estimates significant without calibration, and after calibration cross-correlation and Granger tests still assign ventilator rate -> end-tidal CO2 the sign of the clinician's policy. We propose feedback-robust patient graphs that combine concept nodes with evidence pointers, typed relations admitted against negative controls, and beat-level couplings. On VitalDB under null streams, our graphs contain 0.06-0.10 false concept-level relation instances per graph, versus 10-12 for correlational construction. Patient-specific estimates of 11 slow drug and ventilator responses predict later data no better than population estimates, whereas the pulse-arrival-time-systolic-pressure slope is negative in 94.3% of 2,884 cases and patient-specific (early-late correlation 0.67 [0.63, 0.70]).

Explore similar work

Aug 23, 2026cs.LG

Clinical Graph-JEPA: Predictive Patient-State Knowledge Graphs for Cognitive Decision Support

Clinical records contain rich evidence about patient state, but converting that evidence into reliable, structured knowledge graphs remains difficult because extraction errors, ontology mismatch, missing relations, and temporal ambiguity can propagate into downstream systems. We propose a clinical knowledge graph construction and refinement framework that combines multi-agent relation proposal, ontology-aware normalization, deterministic evidence scoring, and JEPA-based latent refinement. Rather than treating a clinical knowledge graph as a static extraction artifact, we treat it as a predictive patient-state representation. For each admission, the system constructs an evidence-scored graph from structured MIMIC-IV records and inferred clinical cross-links, then learns to recover held-out clinical relations from the observed graph context. We evaluate the refiner with leakage-free leave-one-out edge recovery (MRR and Hits@k) and held-out batch-mask evaluation (AUC and MRR). To isolate the contribution of discharge-note context, we compare a note-embedding-free configuration with a note-augmented configuration that injects real discharge-note representations only into note-grounded entities. Under the same cohort and evaluation protocol, entity-grounded note injection improves overall leave-one-out MRR by 31% relative improvement.
May 11, 2026cs.CL

ClinicalBench: Stress-Testing Assertion-Aware Retrieval for Cross-Admission Clinical QA on MIMIC-IV

Reasoning benchmarks measure clinical performance on clean inputs. We evaluate the step before reasoning: retrieval over real EHR notes, where negation, temporality, and family-versus-patient attribution can flip a correct answer to a wrong one. EpiKG carries an assertion label and a temporality tag with every fact in a patient knowledge graph, then routes retrieval by question intent. ClinicalBench is a 400-question test over 43 MIMIC-IV patients across 9 assertion-sensitive categories. A 7-condition ablation tests each piece of EpiKG across six LLMs (Claude Opus 4.6, GPT-OSS 20B, MedGemma 27B, Gemma 4 31B, MedGemma 1.5 4B, Qwen 3.5 35B). Three physicians blindly adjudicated 100 paired items. The author-blind primary endpoint, leave-author-out paired exact McNemar on 50 unanimous-strict items rated by two external physicians, yields +22.0 percentage points (95 percent Newcombe CI [+5.1, +31.5], p=0.0192). The architectural novelty, intent-aware KG-RAG over a Contriever dense-RAG baseline (C2b to C4g_kw on the change-excluded n=362 endpoint), is +8.84 percentage points (paired McNemar p=1.79e-3); +12.43 percentage points under oracle intent. Sensitivities agree directionally: three-rater physician majority +24.0 percentage points (subject to single-author circularity); deterministic keyword reproducibility proxy +39.5 percentage points. Across the six models, the gain shrinks as the LLM-alone baseline rises (beta=-1.123, r=-0.921, p=0.009). With n=6 this looks more like regression to the mean than encoding substituting for model size. Physician adjudication identified 56 percent of auto-generated reference answers as defective, a methodological finding indicating that NLP-pipeline clinical-QA benchmarks require physician adjudication to be usable. ClinicalBench, the frozen evaluator, three-rater adjudication data, and the EpiKG output stack are publicly released.
Aug 25, 2026cs.AI

Clinical Knowledge Graphs for Chest X-Ray Device Reasoning

Chest radiographs are routinely used to verify the position of catheters, tubes, and other support devices. Existing image models often return labels or segmentations, while report-processing systems structure text without access to image geometry. We present an uncertainty-aware clinical knowledge graph that represents device instances, tip estimates, placement assessments, provenance, report events, and temporal links as separate but connected evidence. We evaluate the implemented visual graph layer using saved predictions from the complete RANZCR CLiP test archive, comprising 30,083 studies from 3,255 patients across five non-overlapping outer folds. The graph builder materializes 914,632 B7 evidence nodes and 884,549 typed relationships. All 118,647 B7 predicted-device nodes retain tip covariance, placement probabilities, fragment provenance, and fragment counts, whereas the direct B2 baseline retains none of these fields. We further define typed data contracts, uncertainty representations, abstention rules, report-image grounding, and longitudinal query mechanisms for extending the graph to report-bearing cohorts. The reported graph-materialization analysis is post-hoc descriptive and does not establish report grounding, longitudinal performance, or clinical utility. It demonstrates a reproducible foundation for evidence-preserving AI reasoning over chest X-ray device assessments.