cs.CVOct 29, 2026

Confidence Filtering in Video-Based Gait Assessment: Measurement Error versus Selection Shift

Authors: David Regev, Eran Beeri Bamani

Organizations: Department of Information Science and Applied Artificial Intelligence, Bar-Ilan University, Ramat Gan, Israel.

Abstract

Video-based gait assessment often keeps only high-confidence pose observations, which can lower measurement error but change the movement assessed. We compared confidence selection with budget-matched random selection in a Parkinson-related cohort (n = 96) and an NF2-related replication cohort (n = 18). In the Parkinson-related cohort, confidence selection produced a small but consistent shift in the observed movement summary (+0.05 SD, 95% CI 0.03 to 0.07), while held-out Mini-BESTest error stayed flat (-0.04 points, -0.13 to 0.05); a policy preserving motion-group proportions reduced the shift, while NF2 showed no shift and its predictor did not beat a constant baseline. Because this shift mixes measurement error with selection shift, we decompose and simulate both on the cohort's window structure. Filtering lowers local error when error depends on confidence, but biases the endpoint once confidence tracks movement more than error. In the Parkinson-related data, confidence was only weakly tied to movement (rho = 0.14). There, filtering is harmless if well-tracked windows are unbiased. If instead systematic error only redistributes within participants, filtering can add up to 0.58 degrees. Unchanged clinical error from such small-cohort predictors therefore cannot show that quality filtering preserves the assessed movement.

Figures & tables

Explore similar work

Sep 18, 2026

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present GaitVista, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, GaitVista reduces average full-body and lower-body error by 27.7% and 27.8%, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from 2.762.76--5.335.33~cm for condition-blind baselines to 1.111.11~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by 6.4% relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by 18.9%. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.
Aug 20, 2026

Aggregate, Don't Adapt: Subject-Level Posterior Aggregation and Transductive Calibration for Cross-Site Parkinsonian Gait Severity

We describe the winning entry to the MoCha 2026 Benchmark and Challenge on Parkinsonian Gait, which predicts MDS-UPDRS gait severity from canonicalized SMPL motion recorded at clinical sites unseen during training. The system reaches 0.6945 macro-F1 on the hidden test and ranked first of 58 entries, ahead of the runner-up at 0.5807 and the organizers' baseline at 0.4289, on a frozen public motion encoder with a single 4×5124\times512 linear layer. Nearly all of the margin comes from three stages usually treated as bookkeeping: reproducing the reference benchmark's exact head recipe, averaging per-walk posteriors within the subject grouping the organizers ship, and a label-free transductive calibration of the feature mean and the decision operating point. Fine-tuning the encoder lost in four distinct forms, and ten alternative encoders were worse. Every ablation number is a paid read on the hidden test, because our own leave-two-cohort-out cross-validation proved anti-correlated with the deciding score over eleven configurations. We give the negative record in full, and identify our largest gain, subject-level aggregation, as the binding ceiling on this benchmark.
Oct 12, 2026

When Participant Disjoint Validation Is Not Enough to Establish Generalization in Parkinson's Gait Classification

Participant-disjoint cross-validation prevents direct participant overlap, but it may still produce optimistic estimates when acquisition site and diagnosis are structurally dependent. We examined Parkinson's disease classification using 159 pressure-walkway summary features from 133 WearGait-PD participants, including 65 participants with Parkinson's disease and 68 controls. The cohort was non-factorial: two sites contained only one diagnostic group, whereas VA-Seattle was the only site containing both groups. In repeated participant-level nested cross-validation, site alone achieved an area under the receiver operating characteristic curve (AUC) of 0.955 plus or minus 0.003, exceeding the gait-feature model (0.882 plus or minus 0.014). Under the evaluated logistic-regression pipelines, adding gait features to site, age, and sex produced no measurable improvement in pooled discrimination. More site-controlled evaluations produced lower and imprecise estimates: VA-Seattle same-site AUC was 0.668 (95% bootstrap confidence interval 0.477 to 0.836), and the JHOC + Bayview-to-VA-Seattle transport stress test achieved 0.576 (0.375 to 0.770). Supporting within-diagnosis site-prediction and site-conditioned permutation analyses showed that the gait representation retained substantial acquisition-site structure. These findings indicate that participant-disjoint pooled validation did not isolate disease-related discrimination from site-associated variation. They encourage careful examination of site-label dependence and, where possible, support for pooled results through within-site or independent validation before broader claims are made about generalization across institutions.