cs.CLOct 29, 2026

Decision and System One models in rheumatology: accuracy and calibration on specialty-training examination questions and diagnostic case vignettes

Authors: Alfredo Madrid-García, Diego Benavent, Fabian Lechner, Phillip Kremer, Johannes Knitza, Beatriz Merino-Barbancho

Organizations: Independent researcher, Madrid, Spain · Rheumatology Department, Hospital Universitari de Bellvitge, Barcelona, Spain · Institute for Digital Medicine, Marburg University, Marburg, Germany · Division of Rheumatology and Systemic Inflammatory Disorders, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

Abstract

Objectives: To evaluate the accuracy and calibration of Decision and System One models on rheumatology examination questions and diagnostic vignettes. Methods: Two benchmarks were analysed: 172 rheumatology questions from Spanish specialty-training examinations (expanded RheumaMIR dataset) in Spanish and English, and 70 English diagnostic vignettes from RheumBench with 5-18 candidate diagnoses, 52 of which included the reference diagnosis. Four System One models (Jev 1.13, Clef, Microsoft-Decision-1, Laya) and GPT-6 Luna (OpenAI Decisions API) were compared with GPT-6 Sol and two local generative models. The primary outcome was accuracy; secondary outcomes included calibration, discrimination, accuracy of answers with probability >=0.90 and language differences. Results: In RheumaMIR, Jev's accuracy was 93.0% in Spanish and 91.9% in English, below GPT-6 Sol (99.4%; Holm-adjusted P<=0.005); GPT-6 Luna reached 97.7%, Clef 91.9-93.0% and Microsoft-Decision-1 86.0-87.8%, without detectable language differences. Jev's answers with probability >=0.90 (76-77% of answers) were 98.5% correct. In RheumBench, accuracy was lower: GPT-6 Sol 76.9%, GPT-6 Luna 63.5%, Clef 59.6%, Jev 50.0% and Microsoft-Decision-1 40.4% (each System One model below GPT-6 Sol, Holm-adjusted P<=0.045; chance 9.6%). Jev became overconfident (mean probability 0.659; over/underconfidence index +0.159), and its answers with probability >=0.90 (25% of cases) were 84.6% correct, against 95.5% for GPT-6 Luna (42%). Laya performed near chance in both benchmarks. Conclusion: The best-performing System One models were highly accurate on examination questions but less accurate on diagnostic vignettes, remaining below GPT-6 Sol. Jev's high-confidence predictions were less reliable on vignettes, highlighting the need for task-specific evaluation and calibration.

Figures & tables

Explore similar work

Sep 27, 2026

Jev in Medicine: A Benchmark Evaluation

Jev is a non-generative System One model that assigns probabilities to predefined answer options and cannot answer outside them. Its accuracy and calibration on medical question-answering and case-based diagnostic-reasoning tasks are unknown. We evaluated Jev 1.13 on four medical benchmarks: MetaMedQA, PubMedQA, DiagnosisArena-MCQ and the NEJM Case Challenges. GPT-6 Sol, with (medium) and without reasoning, was the reference. The primary outcome was top-1 accuracy; key secondary outcomes were calibration, selective prediction and recognition of unanswerable questions. All 8,469 requests returned a valid answer. Jev's accuracy was similar to that of GPT-6 Sol with medium reasoning on PubMedQA (78.4% vs 78.2%;), lower on MetaMedQA (74.8% vs 82.7%) and much lower on DiagnosisArena-MCQ (59.8% vs 82.4%;) and the NEJM cases (61.8% vs 82.4%). On MetaMedQA, Jev's probabilities were the best calibrated (expected calibration error 0.063 vs 0.146), and its answers with a probability of at least 0.9 (52.9% of questions) were 93.4% accurate, but GPT-6 Sol was as accurate when it accepted a similar proportion of questions. On DiagnosisArena-MCQ, Jev's probabilities discriminated poorly (AUROC 0.645 vs 0.768). Of the 162 questions whose correct answer was "I don't know or cannot answer", Jev chose that option for 10.5% (GPT-6 Sol, 8.6%). Median latency was 0.27-0.31 s; all 2,823 items cost USD 0.08. Jev was fast and inexpensive, and its accuracy was similar to that of a frontier LLM on research abstracts but lower on examination questions and much lower on complex diagnostic cases. Task-specific validation is required before clinical use.
Oct 13, 2026

How Reliable Are System-One Decisions in Medicine? A Comparative Study of Jev, Jev-like Models, and LLMs

Jev has attracted considerable attention for its rapid, generalizable decision-making, yet its medical reliability remains underexplored. To address this gap, our study compares various types of system-one decision models across 15 medical datasets comprising 8,742 instances under a unified protocol. Beyond accuracy, we assess decision stability and the ability to recognize unreliable decisions. Our results show that Jev rivals leading models on primarily text-driven tasks but is less effective on numerically driven tasks, revealing a distinct capability boundary. Under question-format variations, Jev maintains strong decision consistency and small accuracy fluctuations. StartLux-27B exhibits comparable consistency, while D3-27B achieves higher overall accuracy and a lower mean decision reversal rate. But these strengths do not extend to reliable abstention awareness: most evaluated models show limitations in both recognizing missing correct answers and using optional abstention. Moreover, we find that Jev's probability-based answer selection can be improved by changing how decisions are scored: normalizing option-wise binary scores yields higher retained accuracy than choice scoring. Taken together, our findings provide early guidance for improving and applying decision models in medicine.
Oct 22, 2026

The Value of System 1 Models in Medicine

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.