cs.CVNov 11, 2026

Real Pairs Are Not Enough: Physically Anchored Supervision for Volumetric CT Super-Resolution

Authors: Haoran Liu, Zipei Yan, Mingzhe Liu, Jizhou Li, Guibin Zan

Organizations: Chengdu University of Technology · The Chinese University of Hong Kong · Specreation Instruments Co., Ltd.

Abstract

Volumetric CT super-resolution (SR) models are commonly trained on synthetic or physically acquired pairs of low-resolution (LR) and high-resolution (HR) volumes. However, synthetic pairs miss real acquisition effects, whereas registered physical pairs retain inter-scan noise, artifact, and microstructure differences---causing direct voxelwise regression, and even naive synthetic-real mixing, to oversmooth fine porous structures. We introduce the Physically-anchored Implicit Network (PIN) with Real-Pair Dual-Anchor learning, which decouples physical-pair supervision into two complementary roles. The HR anchor teaches fine structure from registered HR through pair-conditioned spectral replay, while the LR anchor constrains the prediction from acquired LR via affine-calibrated low-pass projection. Together with exact synthetic supervision in one shared volumetric implicit model, PIN learns from both physical scans without forcing the acquired-LR reconstruction to match registered HR voxel by voxel. Inference requires only acquired LR. Across 30 external baseline configurations on real CT, PIN achieves the lowest full-volume LPIPS, reduces average symmetric surface distance by 42.3-49.5% and bone-volume-fraction error by 52.2-53.4% relative to the three strongest baselines for each metric, and lowers the erased reference-pore volume fraction from 37.3-72.9% to 10.4%. Code, pretrained models, and evaluation scripts will be publicly available.

Figures & tables

Explore similar work

Mar 14, 2026

CT-Conditioned Diffusion Prior with Physics-Constrained Sampling for PET Super-Resolution

PET super-resolution is highly under-constrained because paired multi-resolution scans from the same subject are rarely available, and effective resolution is determined by scanner-specific physics (e.g., PSF, detector geometry, and acquisition settings). This limits supervised end-to-end training and makes purely image-domain generative restoration prone to hallucinated structures when anatomical and physical constraints are weak. We formulate PET super-resolution as posterior inference under heterogeneous system configurations and propose a CT-conditioned diffusion framework with physics-constrained sampling. During training, a conditional diffusion prior is learned from high-quality PET/CT pairs using cross-attention for anatomical guidance, without requiring paired LR--HR PET data. During inference, measurement consistency is enforced through a scanner-aware forward model with explicit PSF effects and gradient-based data-consistency refinement. Under both standard and OOD settings, the proposed method consistently improves experimental metrics and lesion-level clinical relevance indicators over strong baselines, while reducing hallucination artifacts and improving structural fidelity.
Mar 24, 2026

VoDaSuRe: A Large-Scale Dataset Revealing Domain Shift in Volumetric Super-Resolution

Recent advances in volumetric super-resolution (SR) have demonstrated strong performance in medical and scientific imaging, with transformer- and CNN-based approaches achieving impressive results even at extreme scaling factors. In this work, we show that much of this performance stems from training on downsampled data rather than real low-resolution scans. This reliance on downsampling is partly driven by the scarcity of paired high- and low-resolution 3D datasets. To address this, we introduce VoDaSuRe, a large-scale volumetric dataset containing paired high- and low-resolution scans. When training models on VoDaSuRe, we reveal a significant discrepancy: SR models trained on downsampled data produce substantially sharper predictions than those trained on real low-resolution scans, which smooth fine structures. Conversely, applying models trained on downsampled data to real scans preserves more structure but is inaccurate. Our findings suggest that current SR methods are overstated - when applied to real data, they do not recover structures lost in low-resolution scans and instead predict a smoothed average. We argue that progress in deep learning-based volumetric SR requires datasets with paired real scans of high complexity, such as VoDaSuRe. Our dataset and code are publicly available through: https://augusthoeg.github.io/VoDaSuRe/
Oct 14, 2026

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.