cs.CVNov 23, 2026

Decompose and Describe: Narrowing the Diagnosis-to-Report Gap in 3D CT Report Generation

Authors: Zhisong Wang, Wanxing Chang, Weiwei Cao, Fenghe Tang, Bowen Shi, Ruifeng Yuan, Yong Xia, Jianpeng Zhang

Organizations: DAMO Academy, Alibaba Group · Hupan Lab, Hangzhou, China · Department of Radiology, Ningbo No. 2 Hospital, Ningbo, Zhejiang, China · Jiangsu Key Laboratory of Multimodal Digital Twin Technology, Suzhou, Jiangsu, China

Abstract

Automated 3D CT report generation could support radiology workflows, yet medical vision-language models (MedVLMs) often omit diagnostic findings from generated reports. We ask whether the diagnostic ability of these models carries over to free-form reporting. Across five MedVLMs, diagnostic VQA achieves higher macro-F1 than reports generated from the same CT studies and evaluated on the same disease categories. We call this task-dependent discrepancy the diagnosis-to-report gap. Conventional Report Adaptation improves reporting for most models but does not close the gap. To investigate and narrow it, we introduce DeCAD (Decompose CT Analysis and Describe), which progressively decomposes CT report generation at diagnostic, regional textual, and regional visual levels. The model identifies positive findings before writing a report, organizes diagnosis and description into regional tasks, and restricts each task to visual tokens from the corresponding region. Diagnostic and regional textual decomposition improve report-level diagnostic performance across the five MedVLMs, whereas regional visual decomposition provides limited additional gains. In a standard VLM without medical VQA pretraining, the first two levels remain effective; regional visual decomposition also provides further gains with a region-level contrastively pretrained encoder. Full DeCAD achieves state-of-the-art performance on CT-RATE and Merlin. Analyses show greater CT-token attention during diagnosis and higher recall of reference-positive findings in both the diagnostic output and final report than with Report Adaptation. These results show that explicitly organizing diagnosis improves diagnostic reporting and helps narrow the diagnosis-to-report gap.

Figures & tables

Appendix figures & tables16 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 3, 2026

MedScribe: Clinically Grounded CT Reporting through Agentic Workflows

Vision-language models (VLMs) have shown potential for automated radiology report generation, yet existing approaches rely on global embedding compression of volumetric data, often leading to hallucinated findings and limited anatomical grounding in 3D CT imaging. We introduce MedScribe, a hypothesis-driven framework that reformulates report generation as an iterative evidence acquisition process rather than a single-pass encoding task. MedScribe models reporting as a sequential decision process in which a large language model dynamically invokes pathology-specific diagnostic tools to extract localized volumetric features. These structured features are used to query a multidimensional retrieval space aligned with pathology-specific textual evidence. By explicitly accumulating quantitative evidence prior to synthesis, the framework enforces fine-grained grounding and reduces unsupported claims. Without task-specific fine-tuning, MedScribe improves clinical accuracy, factual consistency, and interpretability on CT-RATE and RadChestCT compared to state-of-the-art 2D and 3D VLMs, demonstrating the value of hypothesis-driven reasoning for reliable medical image reporting.
Nov 22, 2026

Decoupling Perception from Generation for Agentic 3D CT Report Generation

Chest CT reports repeatedly assess the same anatomical regions for findings and their attributes, such as whether a lung nodule is present and where it is located. These assessments suggest learning to answer visual questions directly, rather than coupling perception to open-ended text generation. Yet current CT report generation models largely follow generic vision-language modeling, which may miss subtle abnormalities when training data are limited. We therefore formulate report generation as a set of visual question-answering decisions coordinated by a large language model (LLM) agent. This decouples visual perception from reasoning and report writing: perception can be learned as a discriminative, non-generative task, while the LLM focuses on reasoning over patient context and posing relevant visual queries. We introduce Rad-VL-JEPA, which unifies report retrieval, finding recognition, and fine-grained attribute characterization through vision-language joint-embedding prediction. Building on this perception module, an agent trained with reinforcement learning (RL) acquires patient-specific visual evidence, while a separate editor incorporates the evidence into the final report, further separating evidence acquisition from report realization. Experiments show that Rad-VL-JEPA achieves strong performance on fine-grained CT understanding tasks with lower amortized per-query inference time than a generative VLM baseline trained with the same CT encoder and VQA data. The resulting reporting system outperforms strong VLM-based and agentic baselines.
May 29, 2026

Generating Reports or Repeating Templates? Measuring and Mitigating Template Collapse in 3D CT Report Generation

Modern 3D medical vision-language models (VLMs) can generate fluent radiology-style text while exhibit critically low pathology detection and output diversity, collapsing to generic templates that under-report rare yet critical findings. We identify this failure mode as Template Collapse. This failure stems from the unique constraints of 3D medical imaging, e.g., limited data, severe label imbalance, and weak signals from volumetric encoders. Under these constraints, text-generation objectives encourage shortcut learning and fluent but weakly grounded reports. We systematically diagnose the Template Collapse through clinical fidelity, output diversity, normal-template bias, and rare-finding survival. To mitigate it, we propose CLarGen, a decoupled framework that separates what to say (clinical detection) from how to say it (language synthesis). CLarGen uses (i) a Latent Query Transformer for multi-label pathology detection, (ii) pathology-guided retrieval for clinically matched exemplars, and (iii) a medical language model to synthesize the final report from detected findings and retrieved context. Across state-of-the-art 3D CT report generation baselines, CLarGen mitigates Template Collapse and substantially improves clinical accuracy (macro-F1 0.487 vs. 0.189; CRG 0.472 vs. 0.368) while maintaining fluent reporting. Our results suggest that explicit, measurable clinical grounding is essential for template-collapse-resistant 3D CT report generation. Code is available at https://github.com/ai-med/CLarGen.