Organizations: DAMO Academy, Alibaba Group · Hupan Lab, Hangzhou, China · Department of Radiology, Ningbo No. 2 Hospital, Ningbo, Zhejiang, China · Jiangsu Key Laboratory of Multimodal Digital Twin Technology, Suzhou, Jiangsu, China
Automated 3D CT report generation could support radiology workflows, yet medical vision-language models (MedVLMs) often omit diagnostic findings from generated reports. We ask whether the diagnostic ability of these models carries over to free-form reporting. Across five MedVLMs, diagnostic VQA achieves higher macro-F1 than reports generated from the same CT studies and evaluated on the same disease categories. We call this task-dependent discrepancy the diagnosis-to-report gap. Conventional Report Adaptation improves reporting for most models but does not close the gap. To investigate and narrow it, we introduce DeCAD (Decompose CT Analysis and Describe), which progressively decomposes CT report generation at diagnostic, regional textual, and regional visual levels. The model identifies positive findings before writing a report, organizes diagnosis and description into regional tasks, and restricts each task to visual tokens from the corresponding region. Diagnostic and regional textual decomposition improve report-level diagnostic performance across the five MedVLMs, whereas regional visual decomposition provides limited additional gains. In a standard VLM without medical VQA pretraining, the first two levels remain effective; regional visual decomposition also provides further gains with a region-level contrastively pretrained encoder. Full DeCAD achieves state-of-the-art performance on CT-RATE and Merlin. Analyses show greater CT-token attention during diagnosis and higher recall of reference-positive findings in both the diagnostic output and final report than with Report Adaptation. These results show that explicitly organizing diagnosis improves diagnostic reporting and helps narrow the diagnosis-to-report gap.
Figures & tables
Figure 1: Diagnostic ability and report expression in MedVLMs. (a) Diagnostic QA responses and a free-form report generated from the same CT volume. (b) Diagnostic macro-F1 measured from QA answers and generated reports across five MedVLMs on CT-RATE.
Figure 2: DeCAD: progressive task decomposition for 3D CT report generation. (a) Diagnostic decomposition generates an explicit diagnostic assessment before composing the report. (b) Regional textual decomposition organizes diagnostic assessment and report description by region, preserving the assessment-before-description sequence while retaining visual tokens from all target regions. (c) Regional visual decomposition further restricts each regional task to visual tokens associated with the requested region.
CT-CHAT
MedGemma-1.5-4B
Lingshu-7B
HuluMed-7B
RadSight-8B
Setting
F1
P
R
F1
P
R
F1
P
R
F1
P
R
F1
P
R
Diagnostic VQA
31.4
22.7
85.0
20.6
33.7
27.9
24.6
27.5
59.3
46.3
33.4
87.2
49.7
45.1
66.8
Direct
17.8
37.4
18.1
13.7
39.4
12.4
7.1
28.6
5.4
21.3
52.5
15.4
34.6
43.9
30.9
Report Adapt.
17.7
39.7
15.1
19.8
46.0
19.5
21.5
56.2
17.8
37.7
53.8
33.2
37.2
43.8
33.7
Diagnostic Decomp.
30.7
43.9
30.1
32.3
50.7
28.9
30.8
47.2
27.8
45.0
57.4
42.9
42.2
45.3
40.6
Diag.+Text Decomp.
36.6
40.2
42.0
34.2
49.7
30.1
33.4
56.6
29.5
51.4
61.2
48.6
45.8
46.1
49.2
Table 1: Aligned diagnostic evaluation on CT-RATE. F1/P/R are macro-averaged diagnostic metrics evaluated against the same disease labels and reported as percentages. Within each model and metric, the best report-generation score is shaded purple and bold; the second-best distinct score is shaded blue and underlined. Ties share a rank. Diagnostic VQA is excluded from ranking.
Merlin
HuluMed-7B
RadSight-8B
Setting
F1
P
R
F1
P
R
F1
P
R
Diagnostic VQA
–
–
–
17.3
11.4
78.1
40.4
31.3
68.1
Direct
16.8
34.5
16.7
3.8
11.3
4.0
19.8
35.3
16.2
Report Adapt.
25.5
24.5
29.1
10.8
21.1
9.5
32.5
38.1
30.8
Diagnostic Decomp.
27.2
32.2
26.4
16.5
19.5
22.9
36.9
35.7
39.5
Diag.+Text Decomp.
30.7
36.6
31.2
23.9
29.0
26.2
38.7
35.2
45.3
Table 2: Aligned diagnostic evaluation on Merlin. F1/P/R are macro-averaged diagnostic metrics evaluated against the same disease labels and reported as percentages. Within each model and metric, the best report-generation score is shaded purple and bold; the second-best distinct score is shaded blue and underlined. Ties share a rank. Diagnostic VQA is excluded from ranking.
Encoder pretraining
Diag.
Text
Visual
CT-RATE
Merlin
F1
P
R
F1
P
R
Region-level align.
–
–
–
15.9
37.6
15.1
16.6
32.6
14.1
Region-level align.
✓
–
–
39.0
45.7
39.0
23.2
26.2
27.7
Region-level align.
✓
✓
–
41.6
47.2
42.8
34.1
37.1
38.3
Region-level align.
✓
✓
✓
52.1
55.6
54.2
39.4
43.1
42.3
Whole-image align.
✓
✓
–
46.9
51.5
45.8
33.6
30.7
39.0
Table 3: Decomposition ablation without medical VQA pretraining. Diag., Text, and Visual indicate the three decomposition levels. F1/P/R are macro-averaged percentages; bold marks the best result in each column.
Diagnostic
Text
Clinical
Method
F1
P
R
MET
BLEU
RaTE
RG
GR
Lingshu-32B ( Xu et al., 2025 )
9.3
19.7
8.4
10.4
1.0
50.4
5.7
10.8
RadFM ( Wu et al., 2025 )
11.6
19.5
11.2
3.7
0.1
34.8
0.8
1.3
MedGemma-1.5 ( Sellergren et al., 2026 )
13.7
39.4
12.4
7.1
0.7
49.6
10.3
11.1
Reg2RG ( Chen et al., 2025a )
17.1
39.6
12.5
24.6
23.5
66.9
25.2
37.9
BTB3D ( Hamamci et al., 2026a )
17.3
21.0
15.9
20.4
15.8
59.0
15.1
22.2
Table 4: Report-generation comparison on CT-RATE. All scores are reported as percentages. F1/P/R are macro-averaged diagnostic metrics. MET, RaTE, RG, and GR denote METEOR, RaTEScore, RadGraph-F1, and GREEN. For each metric, the best distinct score is shaded purple and bold; the second-best is shaded blue and underlined. Ties share a rank.
Figure 3: Effects of Diagnostic Decomposition on report generation. (a) Attention share assigned to CT visual tokens during Diagnose and Describe . (b) Micro recall of reference-positive findings across generated prefixes; the Describe curve counts findings in the report alone. (c) Report-level precision, recall, and F1 under different levels of training-time Diagnose coverage.
Appendix figures & tables16 assets
Supplementary material from the paper’s appendix.
Appendix
Figure 4: Prompt for region-level report decomposition. The prompt divides the original chest CT Findings and Impression into region-specific report sections for the lung, heart, aorta/mediastinum, and esophagus. It instructs the model to preserve the source clinical information, assign each statement to its relevant anatomical region, and repeat findings involving multiple regions when necessary. The resulting sections provide region-level textual supervision.
Figure 5: Prompt for region-level disease extraction. The prompt extracts explicitly positive abnormalities from chest CT Findings and Impression, assigns each finding to its relevant anatomical region, and normalizes synonymous expressions into standardized disease labels while excluding negated or uncertain findings and repeated mentions within each region.
Disease
Whole-image
Region-level
Emphysema
74.4
75.5
Atelectasis
65.6
65.3
Lung nodule
52.9
61.5
Lung opacity
25.6
71.5
Pulmonary fibrotic sequela
60.7
64.8
Pleural effusion
89.5
81.5
Appendix
Table 5: Zero-shot disease AUC on CT-RATE. AUC across 16 disease categories for visual encoders pretrained with whole-image and region-level image–text contrastive learning, reported as percentages.
Disease
Whole-image
Region-level
Disease
Whole-image
Region-level
Pleural effusion
95.6
97.1
Renal cyst
80.6
83.2
Abdominal aortic aneurysm
77.9
96.8
Appendicitis
58.1
82.9
Bowel obstruction
88.1
95.5
Submucosal edema
75.7
80.0
Splenomegaly
74.3
94.8
Hepatomegaly
68.1
78.3
Surgically absent gallbladder
79.0
93.9
Anasarca
94.3
77.6
Cardiomegaly
86.0
93.8
Ascites
92.9
76.7
Appendix
Table 6: Zero-shot disease AUC on Merlin. AUC across 30 disease categories for visual encoders pretrained with whole-image and region-level image–text contrastive learning, reported as percentages. Mean AUC is the unweighted average across disease categories.
Figure 6: Prompt for region-level report generation.
Figure 7: Prompt for CT-level report generation.
Disease
AUC
F1
Disease
AUC
F1
Atelectasis
100.0
100.0
Metastatic disease
95.7
83.3
Coronary calcification
100.0
100.0
Osteopenia
99.4
88.3
Hepatic steatosis
100.0
100.0
Fracture
97.7
90.7
Pleural effusion
100.0
99.9
Abdominal aortic aneurysm
99.4
90.9
Surgically absent gallbladder
100.0
99.9
Prostatomegaly
97.9
89.6
Gallstones
100.0
99.7
Thrombosis
86.1
89.6
Appendix
Table 7: Report-label extraction performance on Merlin. Per-disease AUC and F1 on the held-out test set, reported as percentages.
CT-CHAT
MedGemma-1.5-4B
Lingshu-7B
Setting
F1
P
R
F1
P
R
F1
P
R
Diagnostic VQA
31.9
19.8
82.2
30.5
31.1
29.9
30.1
20.7
54.5
Direct
30.1
38.1
24.9
15.9
35.3
10.2
11.4
39.5
6.6
Report Adapt.
28.1
44.3
20.6
38.3
51.3
30.5
31.8
55.7
22.3
Diagnostic Decomp.
39.8
42.2
37.7
44.9
55.9
37.5
41.3
55.1
33.0
Diag.+Text Decomp.
45.7
43.2
48.6
44.4
56.1
36.8
44.3
61.5
34.6
Appendix
Table 8: Micro-averaged diagnostic performance on CT-RATE (%), computed using RadBERT. Within each model and metric, the best report-generation score is shaded purple and bold; the second-best distinct score is shaded blue and underlined. Diagnostic VQA is excluded from ranking.
Disease
F1
P
R
Disease
F1
P
R
Pleural effusion
81.2
80.2
82.2
Emphysema
50.6
45.9
56.4
Arterial wall calcification
78.7
72.1
86.6
Hiatal hernia
44.7
31.4
77.6
Coronary artery calcification
74.7
67.3
83.9
Mosaic attenuation
41.2
45.8
37.4
Lung opacity
70.8
78.4
64.6
Pulmonary fibrotic sequela
38.5
51.4
30.8
Consolidation
66.3
65.1
67.5
Lymphadenopathy
37.3
53.4
28.7
Cardiomegaly
63.1
55.6
72.8
Peribronchial thickening
34.5
45.3
27.9
Appendix
Table 9: Per-disease diagnostic performance across 18 disease categories on CT-RATE, evaluated using the RadBERT-based report classifier. Diseases are ordered by F1. Scores are reported as percentages.
Diagnostic
Text
Clinical
Method
Guidance
F1
P
R
MET
BLEU
RaTE
RG
GR
Dia-LLaMA
Classifier
30.4
45.8
26.2
24.0
24.3
66.2
25.7
41.7
DeCAD
Classifier
50.7
44.8
67.9
21.6
19.7
65.8
22.4
37.6
DeCAD
Autoregressive
52.1
55.6
54.2
26.3
27.1
66.5
23.6
42.0
Appendix
Table 10: Comparison of diagnostic guidance strategies on CT-RATE. F1/P/R are macro-averaged diagnostic metrics. MET, RaTE, RG, and GR denote METEOR, RaTEScore, RadGraph-F1, and GREEN. All scores are reported as percentages; bold marks the best result in each column.
CT-CHAT
MedGemma-1.5-4B
Lingshu-7B
Setting
Fine-tuning
F1
P
R
F1
P
R
F1
P
R
Direct
–
17.8
37.4
18.1
13.7
39.4
12.4
7.1
28.6
5.4
Disease Prompt
–
27.2
24.4
40.7
20.6
23.7
38.2
10.8
15.0
17.6
Report Adapt.
✓
17.7
39.7
15.1
19.8
46.0
19.5
21.5
56.2
17.8
Diagnostic Decomp.
✓
30.7
43.9
30.1
32.3
50.7
28.9
30.8
47.2
27.8
Appendix
Table 11: Disease-list prompting and diagnostic decomposition on CT-RATE (%). Within each model and metric, the best score is shaded purple and bold; the second-best distinct score is shaded blue and underlined.
Original image
Shuffled image
Model
AUC
F1
P
R
AUC
F1
P
R
CT-CHAT
69.7
31.4
22.7
85.0
51.4
26.7
17.8
80.0
MedGemma-1.5
70.1
20.6
33.7
27.9
53.2
12.1
16.2
18.5
Lingshu-7B
64.5
24.6
27.5
59.3
51.4
20.8
19.3
50.6
HuluMed-7B
80.9
46.3
33.4
87.2
51.9
27.0
19.3
52.5
RadSight-8B
82.3
49.7
45.1
66.8
51.8
20.7
19.3
27.3
Appendix
Table 12: Diagnostic VQA with original and shuffled CT inputs on CT-RATE. AUC is the macro-average of per-disease AUROC values computed from yes/no logits. F1/P/R are macro-averaged diagnostic metrics. All values are percentages.
Model
VQA
Direct Report
VQA gap
Always-positive gap
CT-CHAT
31.4
17.8
13.6
13.2
MedGemma-1.5
20.6
13.7
6.9
17.3
Lingshu-7B
24.6
7.1
17.5
23.9
HuluMed-7B
46.3
21.3
25.0
9.7
RadSight-8B
49.7
34.6
15.1
−3.6
Appendix
Table 13: Always-positive VQA baseline on CT-RATE. Scores are macro-F1 percentages.
Micro
Macro
Setting
P
R
F1
P
R
F1
Whole-image baseline
44.9
22.2
29.7
37.6
15.1
15.9
Normal/abnormal assessment
44.8
22.1
29.6
24.4
13.9
13.9
Diagnose on 1/3 of cases
53.7
31.3
39.6
43.6
22.3
25.1
Diagnose on 2/3 of cases
53.7
37.5
44.1
44.0
28.6
30.2
Diagnose on all cases
52.4
47.3
49.7
45.7
39.0
39.0
Appendix
Table 14: Effect of diagnostic supervision coverage on whole-image report generation. P, R, and F1 are micro- or macro-averaged diagnostic metrics, reported as percentages. Disease-specific Diagnose supervision is applied to randomly selected subsets of the training cases.
Figure 8: Qualitative comparison on CT-RATE across MedGemma-1.5-4B, HuluMed-7B, and Lingshu-7B. For the same CT study with six ground-truth positive findings, we compare Direct Report, Report Adaptation, and diagnostic + textual decomposition. Green highlights mark generated descriptions corresponding to ground-truth findings, orange text lists ground-truth findings omitted from each report, and red highlights indicate additional findings not described in the reference report. The header of each panel reports the number of ground-truth findings recovered. Across all three models, diagnostic + textual decomposition recovers more reference findings than the corresponding direct and adapted reports.
Figure 9: Qualitative comparison on CT-RATE across RadSight-8B and CT-CHAT-8B. We compare Direct Report, Report Adaptation, and diagnostic + textual decomposition on the same CT study with six ground-truth positive findings. Green highlights mark generated descriptions corresponding to ground-truth findings, orange text lists ground-truth findings omitted from each report, and red highlights indicate additional findings not described in the reference report. The header of each panel reports the number of ground-truth findings recovered. Diagnostic + textual decomposition increases the recovery of reference findings for both models, while conventional report adaptation does not consistently reduce diagnostic omissions.
Vision-language models (VLMs) have shown potential for automated radiology report generation, yet existing approaches rely on global embedding compression of volumetric data, often leading to hallucinated findings and limited anatomical grounding in 3D CT imaging. We introduce MedScribe, a hypothesis-driven framework that reformulates report generation as an iterative evidence acquisition process rather than a single-pass encoding task. MedScribe models reporting as a sequential decision process in which a large language model dynamically invokes pathology-specific diagnostic tools to extract localized volumetric features. These structured features are used to query a multidimensional retrieval space aligned with pathology-specific textual evidence. By explicitly accumulating quantitative evidence prior to synthesis, the framework enforces fine-grained grounding and reduces unsupported claims. Without task-specific fine-tuning, MedScribe improves clinical accuracy, factual consistency, and interpretability on CT-RATE and RadChestCT compared to state-of-the-art 2D and 3D VLMs, demonstrating the value of hypothesis-driven reasoning for reliable medical image reporting.
Giuseppe A. Orlando, Paolo Papotti, Maria A. Zuluaga +2
Inria Centre at Université Côte d’Azur Sophia Antipolis, France · EURECOM Biot, France · Dep. of Nuclear Medicine, Centre Antoine Lacassagne Nice, France Université Côte d’Azur, CNRS, Inserm, iBV
Chest CT reports repeatedly assess the same anatomical regions for findings and their attributes, such as whether a lung nodule is present and where it is located. These assessments suggest learning to answer visual questions directly, rather than coupling perception to open-ended text generation. Yet current CT report generation models largely follow generic vision-language modeling, which may miss subtle abnormalities when training data are limited. We therefore formulate report generation as a set of visual question-answering decisions coordinated by a large language model (LLM) agent. This decouples visual perception from reasoning and report writing: perception can be learned as a discriminative, non-generative task, while the LLM focuses on reasoning over patient context and posing relevant visual queries. We introduce Rad-VL-JEPA, which unifies report retrieval, finding recognition, and fine-grained attribute characterization through vision-language joint-embedding prediction. Building on this perception module, an agent trained with reinforcement learning (RL) acquires patient-specific visual evidence, while a separate editor incorporates the evidence into the final report, further separating evidence acquisition from report realization. Experiments show that Rad-VL-JEPA achieves strong performance on fine-grained CT understanding tasks with lower amortized per-query inference time than a generative VLM baseline trained with the same CT encoder and VQA data. The resulting reporting system outperforms strong VLM-based and agentic baselines.
Modern 3D medical vision-language models (VLMs) can generate fluent radiology-style text while exhibit critically low pathology detection and output diversity, collapsing to generic templates that under-report rare yet critical findings. We identify this failure mode as Template Collapse. This failure stems from the unique constraints of 3D medical imaging, e.g., limited data, severe label imbalance, and weak signals from volumetric encoders. Under these constraints, text-generation objectives encourage shortcut learning and fluent but weakly grounded reports. We systematically diagnose the Template Collapse through clinical fidelity, output diversity, normal-template bias, and rare-finding survival. To mitigate it, we propose CLarGen, a decoupled framework that separates what to say (clinical detection) from how to say it (language synthesis). CLarGen uses (i) a Latent Query Transformer for multi-label pathology detection, (ii) pathology-guided retrieval for clinically matched exemplars, and (iii) a medical language model to synthesize the final report from detected findings and retrieved context. Across state-of-the-art 3D CT report generation baselines, CLarGen mitigates Template Collapse and substantially improves clinical accuracy (macro-F1 0.487 vs. 0.189; CRG 0.472 vs. 0.368) while maintaining fluent reporting. Our results suggest that explicit, measurable clinical grounding is essential for template-collapse-resistant 3D CT report generation. Code is available at https://github.com/ai-med/CLarGen.
Tom Maye-Lasserre, Yitong Li, Bailiang Jian +3
Technical University of Munich (TUM), Germany · TUM Hospital, Germany · Munich Center for Machine Learning (MCML), Germany