Clinical reasoning from incomplete or conflicting patient evidence must account for low-probability but high-risk concerns while remaining grounded in health guidelines. We introduce VerClin, an explainable framework that extracts guideline conditions, exclusions, recommendations, and priorities into executable knowledge and represents patient conversations as scoped cases. A deterministic four-valued reasoner produces traceable guideline matches while preserving uncertainty and enforcing exclusions. Multiple specialty agents then screen matched guidelines for case applicability, and a consultation model synthesizes accepted guidance through specialty recommendations and a sentence-preserving formal-constraint channel. We present accepted guidance in ascending order of the sum of its priority and trigger-strength ranks, which can surface high-risk guidance with weaker triggers. VerClin outperforms direct generation and Top-5 RAG on HealthBench Hard and HealthBench Professional. On the LLMEval-Med subset, it outperforms direct generation and ties Top-5 RAG. Component analyses further examine semantic closure, example-guided refinement, specialty screening, and constraint-conditioned delivery.
Figures & tables
Aspect
GPT-5.2 Default
VerClin
Evidence use
Normal troponin and stable vital signs dominate the response, while the travel history, dyspnea, and calf discomfort receive little attention.
Case IR keeps the exertional symptoms, dyspnea, travel history, calf discomfort, reassuring tests, subjects, and temporal qualifiers in separate evidence-bearing claims.
Guideline match
No explicit record identifies which guideline conditions were considered or remained unresolved.
Executable triggers match guidance concerning ischemic and thromboembolic evaluation, while hard exclusions remain available to prevent incompatible guidance.
Specialty review
The response is produced from a single likelihood-oriented view.
Cardiac and thromboembolic assessors independently review whether the formally matched guidance is applicable and provide case-specific recommendations.
Priority
Likelihood-first organization favors reassurance.
Higher-risk guidance is ordered before lower-priority material so that pulmonary embolism and acute coronary syndrome receive explicit attention despite uncertain probability.
Response
Discharge with outpatient follow-up is presented as plausible.
Constraint-conditioned consultation recommends completing urgent ischemic and thromboembolic assessment and advises against discharge until that evaluation is complete.
Table 1: Illustrative comparison of the baseline and the VerClin workflow on the same constructed scenario.
Figure 1: Overview of VerClin from guideline and case representation through formal matching, multi-agent specialty screening, and constraint-conditioned consultation.
Dataset
Cases
Primary metric
HB-Hard
1,000
Rubric score
HB-Pro
525
Length-adjusted score
LLMEval (MR+MSE)
211
Usability
Table 2: Reported evaluation sets and primary metrics.
System
HB-Hard
HB-Pro
LLMEval
GPT-4.1
13.47
26.96
60.19
GPT-5.2 Default
37.64
41.17
79.62
GPT-5.2 High
40.35
46.92
85.31
Top-5 RAG
45.71
69.89
90.52
VerClin
50.44
74.38
90.52
Table 3: Overall performance in percentage points, using the rubric score for HB-Hard, the length-adjusted score for HB-Pro, and micro-averaged usability on the LLMEval-Med subset.
Figure 2: HB-Hard scores by clinical theme, with bars for subgroup means, dashed lines for overall scores, and whiskers for one bootstrap standard deviation.
Figure 3: HB-Hard scores by evaluation axis, with bars for axis means, dashed lines for overall scores, and whiskers for one bootstrap standard deviation.
Figure 4: Unadjusted HB-Pro scores by use case before length adjustment, with bars for subgroup means, dashed lines for overall scores, and whiskers for one bootstrap standard deviation.
Figure 5: Unadjusted HB-Pro scores for good-faith difficult, good-faith typical, and red-teaming difficult cases before length adjustment, with whiskers for one bootstrap standard deviation.
System
MR
MSE
OP
GPT-4.1
63.73
56.88
60.19
GPT-5.2 Default
70.59
88.07
79.62
GPT-5.2 High
80.39
89.91
85.31
Top-5 RAG
88.24
92.66
90.52
VerClin
86.27
94.50
90.52
Table 4: Usability on LLMEval-Med medical reasoning (MR; 102 cases) and medical safety and ethics (MSE; 109 cases), with OP as the micro-average over all 211 cases; bold denotes the best result in each column.
System
Score
Δ [95% CI]
Frozen full VerClin
74.38
–
No constraint channel
68.70
5.68[3.02,8.41]
Current-code full VerClin
74.20
–
No refinement
69.45
4.76[2.19,7.52]
No semantic closure
65.56
8.65[5.13,12.27]
Table 5: Single-column HB-Pro ablations with their paired full references, where Δ is reference minus ablation in percentage points and all three comparisons have p<.001 . Comparisons are made only within the frozen answer-stage pair or the current-code selector group.
Figure 6: Guideline-applicability screening on HB-Hard, HB-Pro, and the LLMEval-Med MR+MSE subset. A pair is retained if at least one assigned specialty rates it applicable or partially applicable; annotations below the bars show the mean number of guidelines per case before and after screening.
Clinical practice guidelines (CPGs) encode evidence-based decision logic that clinicians apply by evaluating patient variables, conditional criteria, and recommendation rules. However, existing methods often use CPGs as free-text training data or retrieval sources, underutilizing their procedural decision structure. To better exploit this structure, we introduce a guideline-derived training pipeline that transforms CPG recommendations into executable clinical decision logic and uses it to generate factual and counterfactual question-answering data. Theses data teach models both guideline-supported decisions and how decisions change under different patient conditions. Post-training a medical LLM on the generated data yields MedGuideX. Across four clinical reasoning benchmarks, MedGuideX achieves a 10.28% relative improvement in average accuracy. Physician evaluation further shows that MedGuideX better recovers clinician authored reasoning steps and produces physician-preferred rationales in faithfulness, validity, completeness, and clarity. Overall, our results show that executable decision logic from CPGs can be transformed into scalable supervision for building reliable medical LLMs.
Yuhao Shen, Lang Cao, Simo Du +4
University of Illinois Urbana-Champaign · 2The Chinese University of Hong Kong, Shenzhen · 3Albert Einstein College of Medicine
Clinical diagnosis requires answers that are accurate, verifiable, and explicitly grounded in official guidelines. While large language models excel at natural language processing, their tendency to hallucinate undermines their utility in high-stakes medical contexts where precision is essential. Existing retrieval-augmented generation (RAG) systems treat all evidence equally, producing noisy context and generic answers misaligned with clinical practice. We present ClinicBot, an AI system that translates guideline recommendations into trustworthy clinical support through three key advances: (1) structured extraction of clinical guidelines into semantic units (recommendations, tables, definitions, narrative) with explicit provenance, (2) evidence prioritization that ranks content by clinical significance and guideline structure rather than textual similarity, and (3) a web-based interface that presents concise, actionable answers with verifiable evidence. We will demonstrate ClinicBot using diabetes questions from real patients and an additional diabetes risk assessment tool that is faithful to the American Diabetes Association (ADA) Standards of Care in Diabetes (2025). The demonstration will illustrate how semantic knowledge extraction and hierarchical evidence ranking can reliably operate in a multi-agent setting to process complex clinical guidelines at scale.
Navapat Nananukul, Mayank Kejriwal
USC Information Sciences Institute, Los Angeles, California, USA
Clinical practice guidelines (CPGs) encode diagnostic criteria, but LLM systems typically retrieve guideline text or absorb it through training rather than execute its rules. We introduce GuideSkill, an external reasoning layer that compiles disease-specific criteria into executable functions returning ordinal diagnostic-support scores. GuideSkill-Zero is initialized from guidelines, while GuideSkill-Evo uses case--diagnosis pairs to refine covered skills and add missing diagnoses. At inference, an LLM proposes a differential diagnosis, grounds the features required by each matched skill, and fuses its ranking with the executed skill scores. Across four benchmarks and four backbones, GuideSkill-Zero improves macro-average accuracy over guideline RAG by 13.45% on average. GuideSkill-Evo achieves the highest macro-average for every backbone, improves over direct inference by 18.49% relatively, and increases gold-label skill coverage from 56.5% to 99.5%. On Qwen3.5-9B, it also exceeds the strongest parameter-update baseline by 11.16% without updating the backbone. Expert evaluation further indicates that GuideSkill produces clinically sound and broadly acceptable skills, suggesting that its initialized and evolved rules are reliable and practically meaningful. These results support executable skills as a model-agnostic mechanism for combining guideline-derived procedures with case-derived diagnostic patterns.
Lang Cao, Yuhao Shen, Tianyang Luo +3
University of Illinois Urbana-Champaign · ♦The Chinese University of Hong Kong, Shenzhen · ⋂Albert Einstein College of Medicine