Brain MRI Synthesis
MRI: Magnetic Resonance Imaging
Latest papers
10 papers2 papers in the last four weeks, with none the four weeks before. 0.0% of all new papers.
Hospital brain imaging archives hold a diverse array of pathology at sample sizes beyond prospective studies, particularly for underrepresented populations and diseases. To unlock uncurated clinical data and scale analysis, methods are needed to detect abnormalities across contrasts and resolutions. Synthetic data has provided robust, contrast-agnostic models for a variety of human neuroimaging tasks in healthy anatomy, but pathology detection and other tasks in clinical settings still require real patient data, contrast-specific models, or disease-specific generators. We propose PathoDraw, a generative model of brain MRI with pathology. A conditional distribution of lesions given the healthy anatomy is drawn into the label map before contrast-agnostic rendering, and a single network estimates healthy anatomy with exact signed intensity deviation of any input scan. The contrast-agnostic 3D UNet learns the healthy labels under the lesion and the signed deviation directly and identifies pathology via robust tissue statistics and learned features, despite no training on real pathology. We show zero-shot detection on public stroke, tumor, and white matter hyperintensity datasets as well as archived clinical data, spanning w, FLAIR and w at various resolutions under a recent unsupervised anomaly detection benchmark protocol. Our single model exceeds or performs comparably to contrast-specific anomaly detectors trained on real scans and keeps healthy anatomy intact. The same generator trains networks for super-resolution and for registration in the presence of pathology. Our model, robust across acquisition and disease, enables the use of uncurated, archived data for clinical analysis. Our code is available at https://github.com/agr78/Pathology-Randomizer.
Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks
Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.
Federated training performs as well as centralized for 3D Latent Diffusion for Diagnosis-Conditioned Brain MRI Synthesis
Generative models of brain MRI are useful to understand brain conditions, and to enrich scarce and imbalanced neuroimaging data. However, training these models requires large, multi-site training sets, which is challenging. Federated learning (FL) allows for training deep learning models without sharing data. We show that training a 3D conditional latent model federatedly (where data is kept private at each site) performs similarly to centralized training (where all the data have been copied to a single site). We evaluate three metrics: conditional fidelity (how well generated MRIs perform in classification), diversity (how the generated images match the real data distribution, using MultiScale-SSIM), and realism (how close generated images are to real images, using Fréchet Inception Distance). Our results show that federated training is a viable route to develop multi-site generative models of brain MRI.
VoxStruct3D: Structure-Leading Flow Matching for Voxel-Space 3D MRI Synthesis
High-fidelity 3D MRI synthesis requires both globally coherent anatomy and fine-grained voxel-level detail. Although latent diffusion makes volumetric generation tractable, its image autoencoder introduces a reconstruction bottleneck that can limit the fine detail recoverable in the final volume. We present VoxStruct3D, a voxel-space flow-matching framework that directly models full-resolution MRI volumes using a clean-data prediction objective. Its Volumetric Voxel Generator (VVG) combines factorized 3D patch embedding with overlapping upsampling, time-modulated residual refinement, and skip fusion, enabling neighboring tokens to jointly reconstruct shared voxel regions and suppress patch-boundary artifacts. To complement direct voxel-space modeling with an explicit anatomical prior, we further introduce a Structure-First, Image-Follows (SFIF) strategy. A frozen pretrained 3D medical encoder and a StructVAE extract compact structure tokens that preserve dominant anatomy, while a structure-leading schedule keeps their trajectory ahead of the image trajectory. Patch-Aligned RoPE spatially aligns the unequal token grids, and asymmetric attention enforces one-way guidance from structure to image. Experiments on pathological and healthy T1-weighted brain MRI datasets show that VoxStruct3D achieves the strongest overall performance across feature-distribution alignment, sample diversity, and perceptual quality, producing anatomically coherent and visually realistic volumes.
BrainG3N: A Dual-Purpose Tokenizer for Controllable 3D Brain MRI Generation
Three-dimensional (3D) brain MRI is central to clinical neurology and neuro-oncology, where generative models could augment under-represented cohorts, simulate disease trajectories, and support privacy-preserving data sharing. Latent diffusion has been the go-to solution for modeling imaging data, but it places two competing demands on the tokenizer: encoder embeddings must retain the clinical information that downstream tasks act on, and the decoder must reconstruct anatomically faithful volumes. Existing reconstruction-driven tokenizers achieve the second at the expense of the first. To address this, we introduce a fully volumetric masked-autoencoder (MAE) based tokenizer for 3D brain MRI latent diffusion, decoupling encoder and decoder: a frozen 3D MAE encoder produces clinically informative embeddings, while a dedicated CNN decoder reconstructs voxels from a linear projection of those embeddings. We pretrain the encoder on 35,309 volumes from 18 public cohorts spanning four modalities, ten disease categories, and 200+ acquisition sites, and demonstrate its dual utility in two settings. First, on a 23-task linear-probing benchmark, the encoder outperforms or matches SOTA models (i.e., BrainIAC, BrainSegFounder, and MedicalNet) on 21 of 23 tasks. Second, a conditional diffusion transformer (DiT) trained on these clinically informative embeddings supports both conditional generation across six variables and patient-specific longitudinal forecasting. Together these results establish a single 3D brain-MRI embedding space capable of both downstream clinical tasks and controllable generation.
Structural MRI Synthesis for Alzheimer's Disease via Conditional Diffusion on Anatomical Masks
Recent advances in generative machine learning models have significantly improved medical imaging, offering promising solutions for data augmentation, privacy preservation, and improved model generalization. However, synthesizing high-quality structural MRI data for Alzheimer's Disease (AD) remains challenging due to the subtle, region-specific, and progressive anatomical changes associated with neurodegeneration. In this paper, we extend the Med-DDPM conditional diffusion model -- originally designed for brain tumor synthesis -- to generate 3D structural MRIs specifically tailored to AD. We adopted Med-DDPM due to its established stability and structural fidelity compared to other generative models, which makes it particularly suitable for capturing the subtle anatomical changes characteristic of AD. Our approach conditions the diffusion process on anatomical segmentation masks derived from the ADNI dataset, incorporating key AD-relevant brain structures into the generation process. We systematically evaluate the quality and utility of the synthetic images by training segmentation models on real, synthetic, and hybrid (mixed) datasets. Experimental results demonstrate that segmentation models trained exclusively on synthetic data achieve comparable Dice scores (0.6532) to those trained on real data (0.6513), while exhibiting significantly enhanced recall. Notably, models trained on hybrid datasets (mixing real and synthetic images) outperform both real and synthetic-only baselines, achieving a Dice score of 0.7244. These findings underscore the successful use of conditional diffusion models for generating anatomically accurate, AD-specific synthetic MRIs, and highlight their potential for enhancing training data availability, improving diagnostic accuracy, and promoting research reproducibility in neuroimaging studies.
WaveDiT: Distribution-Aware Wavelet Flow Matching for Efficient 3D Brain MRI Synthesis
Large and demographically balanced datasets are essential for reliable neuroimaging biomarkers. Full-resolution 3D brain MRI synthesis can support data augmentation in this setting, but existing approaches either incur prohibitive computational cost at volumetric scale or rely on lossy latent compression that may compromise anatomical detail. As a result, practical 3D generative augmentation often requires specialized compute infrastructure. We propose WaveDiT, a conditional flow matching framework operating in the coefficient space of a 3D Haar Discrete Wavelet Transform. The model combines factorized spatio-depth attention with band-wise heteroscedastic uncertainty modeling derived from higher-order wavelet statistics. Predicted log-variance is integrated directly into both the flow objective and conditioning pathway, enabling adaptive precision consistent with the heavy-tailed and input-dependent variance structure of anatomical detail. This formulation supports full-resolution 3D synthesis under practical memory and time constraints on a single modern GPU. Evaluation on a multi-site cohort demonstrates improved alignment between generated and real MRI distributions, together with enhanced downstream brain age prediction and region-level anatomical agreement relative to diffusion, latent, and wavelet-based baselines. Code is available at https://github.com/sisinflab/WaveDiT
Wavelet-Fusion Diffusion Model for Multimodal Brain MRI Synthesis with Modality and Metadata Conditioning
Multimodal MRI provides complementary information for neuroimaging analysis, where different imaging modalities capture distinct anatomical, tissue, and pathological features that support the development and evaluation of downstream AI applications. Although large-scale structural MRI resources are increasingly available, their modality coverage is often uneven across public and pooled neuroimaging datasets. This uneven modality coverage is further complicated by heterogeneity across sites, scanners, and acquisition protocols, as well as demographic and clinical variables that are often sparse, inconsistently recorded, or unavailable across studies. Synthetic MRI generation can help address this imbalance by synthesizing target-modality volumes for dataset augmentation and controlled synthetic cohort creation. However, many existing MRI synthesis approaches are trained on narrow modality sets or relatively homogeneous cohorts, limiting their applicability to large pooled neuroimaging resources where modality availability, acquisition protocols, and metadata coverage vary substantially across datasets. Diffusion models have become an attractive approach for MRI synthesis because of their strong sample fidelity and diversity, but sampling directly in 3D voxel space is computationally expensive and slow at inference. Latent diffusion improves practicality by synthesizing MRI in a learned, 3D latent space, although generation quality depends on the autoencoder's reconstruction fidelity and the resulting latent distribution. Our approach combines a Wavelet-Fusion variational autoencoder (WF-VAE) latent compressor with a conditional 3D U-Net diffusion model trained in the learned latent space using explicit modality and metadata conditioning. Our proposed Wavelet-Fusion Diffusion Model (WFDM) achieved the strongest distributional alignment among the evaluated synthetic MRI generators.
Brain MR Image Synthesis with 3D Multi-Contrast Self-Attention GAN
Complete and high-quality multi-modal Magnetic Resonance Imaging (MRI) is essential for accurate neuro-oncological assessment, as each contrast provides complementary anatomical and pathological information. However, acquiring all modalities (e.g., T1c, T1n, T2w, T2f) for every patient is often impractical due to prolonged scan times, cost, and patient discomfort, potentially limiting comprehensive tumour evaluation. We propose 3D-MC-SAGAN (3D Multi-Contrast Self-Attention Generative Adversarial Network), a unified 3D multi-contrast synthesis framework that generates high-fidelity missing modalities from a single T2w input while explicitly preserving tumour characteristics. The model employs a multi-scale 3D encoder--decoder generator with residual connections and a novel Memory-Bounded Hybrid Attention (MBHA) block to capture long-range dependencies efficiently, and is trained with a WGAN-GP critic and an auxiliary domain classification head to produce T2f, T1n, and T1c volumes within a unified network. To ensure anatomical and pathological fidelity, we incorporate a frozen 3D U-Net-based segmentation network that enforces a tumour-consistency constraint during training. A composite objective combining adversarial, reconstruction, perceptual, structural similarity, contrast-classification, and segmentation-guided losses further promotes both global realism and tumour-preserving structure. Extensive experiments on 3D brain MRI datasets demonstrate that 3D-MC-SAGAN achieves state-of-the-art quantitative performance and produces visually coherent, anatomically plausible contrasts with improved distributional realism. Importantly, the proposed method maintains tumour segmentation accuracy comparable to that achieved using fully acquired multi-modal inputs, highlighting its potential to reduce acquisition burden while preserving clinically meaningful information.
MedForj: An open, large-scale foundational generative prior for high-resolution 3D brain MRI
This work introduces MedForj, a suite of 3D foundational generative priors based on diffusion models. The MedForj models were trained on 1~mm isotropic 3D -weighted MRI human brain image volumes from subjects, drawn from a curated corpus of volumes from subjects spanning publicly available datasets. These training images were manually inspected to exclude those with poor quality and excessive pathology, and otherwise were minimally processed. The models include six different diffusion training strategies: rectified flow, latent diffusion rectified flow, flow matching, velocity prediction, clean prediction, and noise prediction. Image samples produced by each of these models were compared to each other and against real, ground truth data under downstream segmentation distributions, FID, five inverse problems, and blind human inspection in an observer study. Flow matching was the strongest strategy overall, achieving the best inverse problem solving results at ~dB PSNR and SSIM averaged over the five forward problems, the highest rate of reconstructions judged real by blind human raters at , and the closest per-structure match to real segmented anatomy in a permutation test. It was not best everywhere: rectified flow produced the most convincing unconditional samples in the observer study and the best FID, and the latent rectified-flow model achieved the smallest joint distributional distance to real anatomy. No other strategy, however, performed consistently well across all four evaluations. We therefore recommend flow matching as the default MedForj prior, while releasing every strategy so that the choice can be revisited per application. All model weights and corresponding code are publicly available at https://github.com/piksl-research/medforj.