Data Center Energy Management
Latest papers
15 papers0 papers in the last four weeks, against 2 the four weeks before. 0.0% of all new papers.
The rapid expansion of artificial intelligence is transforming data centres into one of the world's fastest-growing sources of electricity demand. As AI systems scale in size and capability, the physical infrastructure supporting computation is approaching critical limits in energy availability, cooling capacity, land use, freshwater consumption, and carbon management. Conventional land-based data centres are increasingly constrained by urban land competition, grid congestion, environmental pressures, and lengthy permitting processes, raising fundamental questions about where future computing infrastructure can sustainably exist. This article examines floating and offshore data centres as an emerging alternative model for digital infrastructure. By relocating computation to marine environments, offshore systems can exploit the ocean's natural cooling capacity, reduce freshwater dependence, and enable direct integration with offshore renewable energy resources such as wind, wave, and tidal power. Early deployments have demonstrated the potential for significantly improved energy efficiency and operational reliability compared with conventional facilities, while also opening new possibilities for distributed and resilient computing architectures. The article explores how offshore computing may reshape the future relationship between electrification, renewable energy, and large-scale AI infrastructure. It analyses the opportunities and trade-offs associated with marine deployment, including environmental impacts, engineering design challenges, economic feasibility, and regulatory governance. Rather than treating offshore data centres as experimental novelties, the article presents them as part of a broader systems-level transition in how society may power, cool, and sustain the next generation of computational growth.
Artificial Intelligence for Energy Optimization in Data Centers
Data centers are increasingly optimized by artificial intelligence and, at the same time, increasingly loaded by it. The literature treats these as two unrelated problems: control studies model workload as an exogenous arrival process, while sustainability studies model infrastructure as a fixed multiplier. We screen roughly 194 papers retrieved through a documented protocol, code 63 of them, and report what the coding shows. Of 28 primary control-oriented studies, 18 are validated in simulation alone and 5 reach physical hardware or a production facility; none account for water withdrawal, and none account for embodied carbon. Reported savings intervals across four technique families overlap almost completely, which means the field cannot presently rank its own methods. Ten recurring gaps are scored for consequence and tractability, and we set out CLEAR-DC, a framework coupling a control-policy branch to a workload-demand branch through an explicit elasticity term, reads out net rather than direct benefit, and emits a schema-conformant record covering energy, carbon, water, embodied share and validation venue. The framework is an architectural and methodological proposal, not a trained system; the contribution we defend empirically is the corpus analysis and the reporting schema derived from it. Coding sheet, derived statistics and all result artifacts: https://github.com/Kimalice/AI-for-Energy-Optimization-in-Data-Centers-Closing-the-Optimizer-Load-Loop
LLM-Powered Predictive Decision-Making for Sustainable Data Center Operations
The growing demand for AI-driven workloads, particularly from Large Language Models (LLMs), has raised concerns about the significant energy and resource consumption in data centers. This work introduces a novel LLM-based predictive scheduling system designed to enhance operational efficiency while reducing the environmental impact of data centers. Our system utilizes an LLM to predict key metrics such as execution time and energy consumption from source code, and it has the potential to extend to other sustainability-focused metrics like water usage for cooling and carbon emissions, provided the data center can track such data. The predictive model is followed by a real-time scheduling algorithm that allocates GPU resources, aiming to improve sustainability by optimizing both energy consumption and queuing delays. With fast inference times, the ability to generalize across diverse task types, and minimal data requirements for training, our approach offers a practical solution for data center scheduling. This framework demonstrates strong potential for advancing sustainability objectives in AI-driven infrastructure. Through our collaboration with a data center, we achieved a 32% reduction in energy consumption and a 30% decrease in waiting time.
InFactPlanner: Planning Sustainable Geo-Distributed LLM Data Centers
The rapid growth of LLM inference is shifting sustainability concerns from one-time training to continuous serving, where infrastructure decisions shape energy use, carbon emissions, water consumption, and service quality. Yet operators often need to compare deployment alternatives before large-scale infrastructure is built, making direct measurement costly, slow, and sometimes infeasible. We present InFactPlanner, a trace-driven decision-support framework for what-if analysis of sustainable AI data center deployment for LLM inference across single and geo-distributed sites. InFactPlanner combines query traces, hardware-model profiles, candidate site configurations, PUE/WUE parameters, renewable generation models, and time-varying grid carbon intensity to estimate power, energy, carbon emissions, water use, latency, and server utilization. The framework abstracts low-level serving effects into configurable hardware-model profiles, enabling rapid comparison of site selection, capacity placement, hardware, model, renewable integration, and routing choices. We validate the energy accounting pipeline by reproducing reference LLM inference energy estimates with less than 10% deviation, evaluate scalability across multiple data centers and server counts, and demonstrate scenario-driven decision analyses for hardware selection, renewable placement, geographic deployment, and carbon-aware routing. Our results show that sustainability-optimal choices can differ from latency-optimal ones, and that the carbon value of deployment depends strongly on the local grid mix.
Cutting AI Datacenter Energy with Reinforcement Learning: Measured Power Control of LLM Training from One GPU to the Fleet
Reinforcement-learning post-training dominates modern language-model development, yet its power behavior on GPU hardware has not been characterized, and datacenters manage GPU power with workload-blind mechanisms, static caps and reactive throttling, that slow hardware indiscriminately. We instrument GRPO training with half-second power telemetry at 7B, 14B, and 72B scales on one to four A100s (380,000+ samples), and train a PPO meta-controller that adapts the workload's own generation parameters to measured power. Against the full 500-step 7B trace, the controller cuts power-limit violations by 89.8% while increasing token output by 18.1% and energy efficiency by 26.2% (tokens per MWh). Deployed live at 72B, the same controller family yields replicated null results, diagnosed as the group-size actuator losing authority under model sharding. An actuator-authority sweep shows the same parameters applied as generation concurrency retain 17-22% power authority, isolating an occupancy-versus-volume principle; a controller rebuilt on that actuator controls a live 72B rollout-generation workload across three replications: 35.7% more output than a static safe baseline at 2.27 +/- 1.08% budget violations, 87.2% fewer violations than uncontrolled operation, and the best mean throughput and energy per token among constrained controllers, with an adaptive threshold rule matching it in one of three operating conditions. Under realistic measurement windows the original 72B transients fall from 23.6% at half-second resolution to 1.6% at 30 s and zero at 5 min; a composed 16-GPU fleet shows zero violations at 30 s and longer, with peak demand at 50-56% of nameplate. For this fleet mix, roughly twofold oversubscription of nameplate appears feasible, subject to operator validation. We quantify the economic and carbon consequences and specify a low-cost operator pilot.
A Phased Development Framework Enabling Islanded Operation of Sustainable AI Data Centers With Onsite Grid-Following and Grid-Forming Energy Architectures
As hyperscale and colocation AI data centers continue to expand, the electric grid is increasingly required to support large, concentrated loads, with individual facilities ranging from 500 MW to 2 GW. Current projections estimate that approximately 50 GW of AI data center capacity will require grid connectivity in the United States by 2030. While prior research has extensively examined the environmental and operational impacts of AI data centers, as well as their potential role as grid-interactive assets, limited attention has been given to the challenges associated with their scalable deployment through engineering, procurement, and construction (EPC) processes. This manuscript addresses this gap by proposing a phased development framework for AI data center expansion. The approach is designed to enable developers to meet aggressive time-to-market objectives while navigating multi-year constraints associated with interconnection approvals and lead times associated with the procurement of component equipment. A modular construction architecture is presented, along with a detailed analysis of integrated energy systems and the role of hybrid on-site generation in supporting incremental capacity growth. Electromagnetic transient simulations (EMT) are used to evaluate system performance, demonstrating that a combination of on-site natural gas generation and grid-forming energy storage can reliably support data center operations during early and intermediate deployment phases. The study further examines the transition to full grid interconnection, including the capability of the data center to operate in islanded mode during grid disturbances. Finally, the manuscript compares grid-forming control strategies for system reconnection and restoration under varying conditions.
Hierarchical Multi-Agent Reinforcement Learning for Carbon-Aware AI Data Centers in Power Distribution Systems
Eco-friendly energy management for artificial intelligence data centers (AIDCs) is crucial because of the significant increase in energy consumption-induced carbon emissions from AIDCs resulting from the rapid expansion of AI applications. This paper proposes a hierarchical carbon-aware multi-agent reinforcement learning (CA-MARL) framework for robust and efficient operations of AIDCs under uncertainties while ensuring low-carbon operation of power distribution systems. The framework comprises a workload manager (WM) agent and multiple local AIDC agents trained using a multi-agent transformer method, corresponding to a global AIDC aggregator and a local AIDC operator, respectively. Leveraging AIDC operation data along with nodal carbon intensity (NCI) calculated from the carbon emission flow-integrated distribution system operator problem, the WM agent spatially allocates AI training and inference jobs among all AIDCs. Based on the jobs allocated from the WM agent and NCI information, each AIDC agent schedules economical and eco-friendly operations of the AIDC by performing the following tasks: i) temporal shifting of training jobs, ii) spatial allocation of training graphics processing unit (GPU) blocks and inference GPUs within the AIDC, and iii) control of the supply air temperature of the cooling system. The effectiveness of the proposed framework was assessed using an IEEE 33-node power distribution system.
Toward an Energy-Optimized Operation of Data Centers Located in Wind Farms Using Reinforcement Learning
This paper studies Reinforcement Learning as an online controller for curtailment-aware workload shifting in wind-turbine-integrated high-performance computing (HPC) data centers. We introduce a reproducible fixed-day simulation framework with synthetic wind and price signals and delayed completion feedback, designed to be extensible toward more complex scenarios. As a controlled benchmarking basis, we then focus on the minimal case with one wind turbine and one co-located data center. In this setting, pure Reinforcement Learning exhibits a pronounced credit-assignment problem and tends to underuse free wind energy early in the day. We therefore evaluate two complementary countermeasures: optimization-based Imitation Learning and potential-based Reward Shaping. Across multi-seed training and a 200-day test set, Proximal Policy Optimization (PPO) and a Soft Actor-Critic (SAC) variant with an additional on-policy update routine achieve strong empirical performance among learned policies, and both Imitation Learning and Reward Shaping provide improvements in relevant configurations. A performance gap to the optimizer remains, which is expected: the optimizer plans offline with full-day foresight, whereas Reinforcement Learning must decide online from current observations without future realizations. The benchmark and ablation results provide a transparent basis for extending the approach toward richer multi-site and continuous-time scenarios.
Power-Flexible AI Data Centers: A New Paradigm for Grid-Responsive Compute
The rapid expansion of artificial intelligence (AI) infrastructure is driving unprecedented growth in electricity demand from data centers. Traditional power-system planning treats large computing facilities as inflexible peak loads, leading to costly infrastructure upgrades and long delays in grid interconnection. Recent work has shown that AI clusters can reduce electricity consumption during peak demand through software-based workload orchestration. This article explores how modern GPU-based AI data centers can operate as grid-interactive assets that respond dynamically to power system conditions. We describe an architecture integrating grid signals, workload scheduling, and power telemetry for fine-grained cluster power control. Experimental results from a real-world deployment on a 130 kW GPU cluster demonstrate multiple forms of flexibility, including rapid load reduction, sustained curtailment, and carbon-aware operation while preserving service levels for priority jobs. We further demonstrate performance-aware load shifting across geographically distributed clusters, enabling workloads to migrate toward regions with lower grid stress. Together, these capabilities transform AI infrastructure from static electricity consumers into flexible resources that support grid reliability, accelerate interconnection, and improve computing sustainability.
A Scalable Digital Twin Framework for Energy Optimization in Data Centers
This study proposes a scalable Digital Twin framework for energy optimization in data centers.The framework integrates IoT-based data acquisition, cloud computing, and machine learning techniques to enable real-time monitoring, forecasting, and intelligent energy management. A controlled small-scale data center environment was developed to monitor variables such as power consumption, temperature, and computational workload. Long Short-Term Memory (LSTM) models were employed to predict energy demand and support operational decision-making. Experimental results demonstrated improvements in energy efficiency, including reductions in power consumption and enhancements in Power Usage Effectiveness (PUE). Despite being evaluated in a constrained environment, the proposed framework demonstrates strong potential as a scalable and cost-effective solution for sustainable data center management.
OpenG2G: A Simulation Platform for AI Datacenter-Grid Runtime Coordination
AI's growing compute demand and new datacenter buildouts present major capacity and reliability challenges for the electricity grid, leading to multi-year interconnection delays for new datacenters and bottlenecking AI growth. To ease this strain, datacenters increasingly offer rapid power flexibility in response to grid signals, where the datacenter can increase or decrease its power consumption by adapting its workload in real time. In order to understand the impact of large datacenters on the grid and to facilitate the design of effective coordination strategies, we build OpenG2G, a simulation platform for AI datacenter-grid runtime coordination. We show that OpenG2G is capable of answering a wide range of coordination questions by allowing users to implement and compare various control paradigms (including classic, optimization, and learning-based controllers), and quantify how AI model and deployment choices affect datacenter flexibility and coordination outcomes. This versatility is enabled by OpenG2G's modular and extensible architecture: a datacenter backend driven by real measurements of production-grade AI services, a grid backend built on high-fidelity grid simulators, and a generic controller interface that closes the loop between them. We describe the design of OpenG2G and demonstrate its usefulness through realistic grid scenarios and AI workloads.
Joint Energy Management and Coordinated AIGC Workload Scheduling for Distributed Data Centers: A Diffusion-Aided Reward Shaping Approach
Artificial intelligence-generated content (AIGC) has emerged as a transformative paradigm for automating the creation of diverse and customized content, giving rise to rapidly growing computational workloads in cloud data centers. It is imperative for AIGC service providers (ASPs) to strategically schedule AIGC workloads to reduce data center energy costs while guaranteeing high-quality content generation. However, the distinctive characteristics of AIGC services pose critical challenges, including model heterogeneity across ASPs, implicit service quality evaluation, and complex inference process control. To tackle these challenges, we propose a joint energy management and coordinated AIGC workload scheduling framework, which introduces an explicit mathematical characterization of service quality to promote both job transfer among ASPs and fine-grained inference process configuration. Moreover, various energy resources within data centers are jointly considered to enhance power usage flexibility. Subsequently, a system utility maximization problem is formulated to balance AIGC service revenue with operational penalties and costs. Nevertheless, the strong coupling among job scheduling decisions induces severe reward sparsity, which limits the effectiveness of existing deep reinforcement learning (DRL) algorithms. To address this issue, we develop a diffusion model-aided reward shaping approach to synthesize complementary reward signals through a multi-step denoising process. This approach is seamlessly integrated with DRL to enable efficient learning of scheduling policies under sparse environmental feedback. Experiments based on real-world models and datasets demonstrate that our scheme effectively accommodates electricity price fluctuations and AIGC model heterogeneity, while achieving superior learning convergence and system utility compared with benchmark methods.
DataCenterGym: A Physics-Grounded Simulator for Multi-Objective Data Center Scheduling
Modern datacenters schedule heterogeneous workloads across geo-distributed sites with diverse compute capacities, electricity prices, and thermal conditions. Compute utilization, heat generation, cooling demand, and energy consumption are tightly coupled, yet most existing schedulers abstract these effects and treat them independently. We present DataCenterGym, a physics-grounded simulation environment for job scheduling in geo-distributed data centers, designed as a reusable testbed for future research. The simulator integrates compute queueing, building thermal dynamics, localized HVAC behavior, and temperature-dependent service degradation within a Gymnasium-compatible interface. We also develop a Hierarchical Model Predictive Control (H-MPC) scheduling algorithm that performs distributed job placement while explicitly accounting for thermal and power dynamics. Through experiments on nominal operation and workload sensitivity, we demonstrate how H-MPC improves scheduling performance relative to baseline schedulers.
A Physics-Aware Framework for Short-Term GPU Power Forecasting of AI Data Centers
AI data centers experience rapid fluctuations in power demand due to the heterogeneity of computational tasks that they have to support. For example, the power profile of inference and training of large language models (LLMs) is quite distinct and big divergences can result in the instability of the underlying electricity grid. In this paper we propose, to the best of our knowledge, the first physics-informed DLinear time-series model that can accurately forecast power utilization of an AI data center 5-80 minutes (short-term forecasting) into the future. The physics, based on a multi-node lumped thermal resistance-capacitance (RC) network consistent with Newton's law of cooling, is captured using newly derived time-dependent ordinary differential equations (ODE) that separately models and interlinks power consumption with the GPU compute and memory utilization and temperature. The resulting model, that we refer to as PI-DLinear, trained and evaluated on a real AI data center dataset and is not only more accurate than the state-of-the-art (SOTA) models tested, but the forecast profile respects the underlying physics under power throttling and load transient events. Relative to the SOTA transformer-based and non-transformer-based models, improvements in forecasting accuracy (averaged across all look-back and prediction windows) range from 0.782%-39.08% for MSE, 0.993%-51.82% for MAE, and 0.370%-22.28% for RMSE.
End-to-End Learning-based Operation of Integrated Energy Systems for Buildings and Data Centers
Buildings and data centers (DCs) are energy-intensive sectors, playing a critical role to achieve the low-carbon and sustainable energy transition targets. To this end, integrated energy system (IES) that incorporates diverse renewables, energy generation, conversion, and storage technologies to enable coordinated multi-energy supply have been widely investigated for both buildings and DCs. However, few works consider the two sectors jointly within IES to exploit their substantial synergistic benefits. Meanwhile, the operational optimization of IES remains challenging due to the difficulty to predict the multi-energy demand and supply accurately. To address these gaps, this paper investigates IES for coordinated multi-energy supply of buildings and DC, where the waste heat from DCs is recovered and reused to enhance energy efficiency. Moreover, an end-to-end learning-based method is proposed for the operational optimization of IES under uncertainty. Unlike conventional predict-then-optimize approaches, the proposed method integrates the training of prediction models for uncertain variables with the constrained optimization of IES into a unified learning framework, guiding the training of prediction models to improve operational performance, rather than prediction accuracy, thereby mitigating the impacts of predictions errors. Case studies based on real-world datasets show that the proposed methods improves the operational performance of IES by about 7-9% compared to existing predict-then-optimize methods. In addition, coordinating buildings and DCs within IES shows substantial economic benefits. In particular, the waste heat recovery from DCs leads to approximately 10% of total energy cost reduction of the IES.