cs.CVFeb 24, 2026

Beyond Human Performance: A Vision-Language Multi-Agent Approach for Quality Control in Pharmaceutical Manufacturing

Authors: Subhra Jyoti Mandal, Lara Rachidi, Puneet Jain, Matthieu Duvinage, Sander W. Timmer

Organizations: GSK, Enterprise AI · Databricks

Abstract

Colony-forming unit (CFU) detection is critical in pharmaceutical manufacturing, serving as a key component of Environmental Monitoring programs and ensuring compliance with stringent quality standards. Manual counting is labor-intensive and error-prone, while deep learning (DL) approaches, though accurate, remain vulnerable to sample quality variations and artifacts. Building on our earlier CNN-based framework (Beznik et al., 2020), we evaluated YOLOv5, YOLOv7, and YOLOv8 for CFU detection; however, these achieved only 97.08 percent accuracy, insufficient for pharmaceutical-grade requirements. A custom Detectron2 model trained on GSK's dataset of over 50,000 Petri dish images achieved 99 percent detection rate with 2 percent false positives and 0.6 percent false negatives. Despite high validation accuracy, Detectron2 performance degrades on outlier cases including contaminated plates, plastic artifacts, or poor optical clarity. To address this, we developed a multi-agent framework combining DL with vision-language models (VLMs). The VLM agent first classifies plates as valid or invalid. For valid samples, both DL and VLM agents independently estimate colony counts. When predictions align within 5 percent, results are automatically recorded in Postgres and SAP; otherwise, samples are routed for expert review. Expert feedback enables continuous retraining and self-improvement. Initial DL-based automation reduced human verification by 50 percent across vaccine manufacturing sites. With VLM integration, this increased to 85 percent, delivering significant operational savings. The proposed system provides a scalable, auditable, and regulation-ready solution for microbiological quality control, advancing automation in biopharmaceutical production.

Figures & tables

Explore similar work

Mar 11, 2026

Colony Grounded SAM2: Zero-shot detection and segmentation of bacterial colonies using foundation models

The detection and classification of bacterial colonies in images of agar-plates is important in microbiology, but is hindered by the lack of labeled datasets. Therefore, we propose Colony Grounded SAM2, a zero-shot inference pipeline to detect and segment bacterial colonies in multiple settings without any further training. By utilizing the pre-trained foundation models Grounding DINO and Segment Anything Model 2, fine-tuned to the microbiological domain, we developed a model that is robust to data changes. Results showed a mean Average Precision of 93.1% and a Dice@detectionDice@detection score of 0.85, showing excellent detection and segmentation capabilities on out-of-distribution datasets. The entire pipeline with model weights are shared open access to aid with annotation- and classification purposes in microbiology.
Aug 13, 2026

VLM- and LLM-Driven Multi-Agent System for PET Image Denoising

Positron emission tomography (PET) imaging suffers from limited spatial resolution and low signal-to-noise ratio, which can compromise quantitative accuracy and lesion detectability. Deep learning-based denoising methods have demonstrated strong potential for improving PET image quality. However, their practical deployment in real-world settings remains challenging, often requiring multiple specialized models and expert interventions, such as identifying motion-induced misregistration artifacts, estimating noise levels to select an appropriate denoiser, and performing lesion-focused quantitative assessment after denoising. Recent advances in vision-language models (VLMs) for image quality understanding and large language models (LLMs) for contextual reasoning provide new opportunities for automated, decision-driven workflows. Inspired by expert workflows for PET image quality enhancement, we propose an VLM- and LLM-driven multi-agent PET denoising framework that dynamically assesses image quality and lesion status, autonomously selects optimal denoising models and parameters, and enables closed-loop feedback with rollback mechanisms. Experiments were conducted on Siemens Biograph Vision Quadra PET/CT data with 1/20 and 1/50 low-dose settings. Individual module evaluations demonstrated the reliability of the agentic components, while the complete framework achieved higher PSNR and SSIM than UNet, GAN, and DDPM baselines at both dose levels. These preliminary results demonstrate the feasibility of using a closed-loop multi-agent framework to adapt PET denoising strategies to different image conditions.
May 15, 2026

End-to-end plaque counting and virus titration from laboratory plate images with deep learning

Plaque assays remain the gold standard readout of virus infectivity; however, plaque counting from plate images is labor-intensive and prone to inter-operator variability. We present an end-to-end, computer-aided workflow for cytopathic effect-based virus titration directly from laboratory plaque assay images. The proposed approach combines two models derived from the Segment Anything Model (SAM): a SAM2-based well-segmentation module that localizes assay wells across heterogeneous imaging conditions, and a SAM-based plaque-segmentation model that detects and enumerates plaques within each well. The method was evaluated on a mixed dataset comprising private plaque assay images of Mayaro virus and Coxsackievirus B3, together with public Vaccinia virus images from the VACVPlaque dataset. The pipeline outputs per-well plaque counts, automatically computes plaque-forming units per milliliter (PFU/mL), and is integrated into a web-based platform that allows users to review results and organize experiments. On held-out plates (17 from MAYV/CVB3 and 22 from VACV), the workflow generalized across two plate formats (6-well and 12-well) and showed strong agreement with manual annotations (Pearson correlation coefficients of 0.92 for MAYV/CVB3 and 0.88 for VACV). Automated plaque counts were further compared with annotations from four independent experts, demonstrating high concordance. The proposed system will be open sourced and publicly released upon acceptance of this manuscript to enable reproducible, scalable, and audit-ready plaque assay analysis while substantially reducing manual annotation effort.