cs.CVFeb 27, 2026

AdURA-Net: Adaptive Uncertainty and Region-Aware Network

Authors: Antik Aich Roy, Ujjwal Bhattacharya

Organizations: Indian Statistical Institute, Kolkata, India

Abstract

One of the common issues in clinical decision-making is the presence of uncertainty, which often arises due to ambiguity in radiology reports, which often reflect genuine diagnostic uncertainty or limitations of automated label extraction in various complex cases. Especially the case of multilabel datasets such as CheXpert, MIMIC-CXR, etc., which contain labels such as positive, negative, and uncertain. In clinical decision-making, the uncertain label plays a tricky role as the model should not be forced to provide a confident prediction in the absence of sufficient evidence. The ability of the model to say it does not understand whenever it is not confident is crucial, especially in the cases of clinical decision-making involving high risks. Here, we propose AdURA-Net, a geometry-driven adaptive uncertainty-aware framework for reliable thoracic disease classification. The key highlights of the proposed model are: a) Adaptive dilated convolution and multiscale deformable alignment coupled with the backbone Densenet architecture capturing the anatomical complexities of the medical images, and b) Dual Head Loss, which combines masked binary cross entropy with logit and a Dirichlet evidential learning objective.

Figures & tables

Explore similar work

Jul 22, 2026

Bayesian uncertainty estimation improves clinical decision making in medical AI agents

Machine learning models for medical image analysis typically lack a reliable measure of confidence, limiting their use in ambiguous or atypical cases. Here we show that Monte Carlo dropout, applied to a multi-task chest-radiograph classifier (eight thoracic findings, 137,593 training images), provides an epistemic uncertainty signal that tracks generalisation across training-set scales and flags confident yet error-prone predictions. Adding this signal to the point prediction raised error-detection AUROC from 0.74 to 0.77 (ΔΔAUROC +0.023, 95% CI [+0.014, +0.033]). In a controlled 2x2 factorial experiment, a clinical-decision-support agent exploited this uncertainty only when it was delivered as a binary error-risk flag rather than as raw scores, cutting confident misdiagnoses on unreliable findings from 8.5% to 2.7%. Epistemic uncertainty estimation thus carries decision-relevant information beyond point predictions, but its value for downstream agents depends on how it is communicated.
Sep 24, 2026

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.
Apr 10, 2026

MedFormer-UR: Uncertainty-Routed Transformer for Medical Image Classification

To ensure safe clinical integration, deep learning models must provide more than just high accuracy; they require dependable uncertainty quantification. While current Medical Vision Transformers perform well, they frequently struggle with overconfident predictions and a lack of transparency, issues that are magnified by the noisy and imbalanced nature of clinical data. To address this, we enhanced the modified Medical Transformer (MedFormer) that incorporates prototype-based learning and uncertainty-guided routing, by utilizing a Dirichlet distribution for per-token evidential uncertainty, our framework can quantify and localize ambiguity in real-time. This uncertainty is not just an output but an active participant in the training process, filtering out unreliable feature updates. Furthermore, the use of class-specific prototypes ensures the embedding space remains structured, allowing for decisions based on visual similarity. Testing across four modalities (mammography, ultrasound, MRI, and histopathology) confirms that our approach significantly enhances model calibration, reducing expected calibration error (ECE) by up to 35%, and improves selective prediction, even when accuracy gains are modest.