cs.CVMar 7, 2026

Virtual Intraoperative CT (viCT): Sequential Anatomic Updates for Modeling Tissue Resection Throughout Endoscopic Sinus Surgery

Authors: Nicole M. Gunderson, Graham J. Harris, Jeremy S. Ruthberg, Pengcheng Chen, Di Mao, Randall A. Bly, Waleed M. Abuzeid, Eric J. Seibel

Organizations: Department of Mechanical Engineering, University of Washington, Seattle, WA, USA. · Department of Otolaryngology–Head and Neck Surgery, University of Washington Medical Center, University of Washington, Seattle, WA, USA.

Abstract

Purpose: Incomplete dissection is a common cause of persistent disease and revision endoscopic sinus surgery (ESS) in chronic rhinosinusitis. Current image-guided surgery systems typically reference static preoperative CT (pCT), and do not model evolving resection boundaries. We present Virtual Intraoperative CT (viCT), a method for sequentially updating pCT throughout ESS using intraoperative 3D reconstructions from monocular endoscopic video to enable visualization of evolving anatomy in CT format. Methods: Monocular endoscopic video is processed using a depth-supervised NeRF framework with virtual stereo synthesis to generate metrically scaled 3D reconstructions at multiple surgical intervals. Reconstructions undergo rigid, landmark-based registration in 3D Slicer guided by anatomical correspondences, and are then voxelized into the pCT grid. viCT volumes were generated using a ray-based occupancy comparison between pCT and reconstruction to delete outdated voxels and remap preserved anatomy and updated boundaries. Performance is evaluated in a cadaveric feasibility study of four specimens across four ESS stages using volumetric overlap (DSC, Jaccard) and surface metrics (HD95, Chamfer, MSD, RMSD), and qualitative comparisons to ground-truth CT. Results: viCT updates show agreement with ground-truth anatomy across surgical stages, with submillimeter mean surface errors. Dice Similarity Coefficient (DSC) = 0.88 +/- 0.05 and Jaccard Index = 0.79 +/- 0.07, and Hausdorff Distance 95% (HD95) = 0.69 +/- 0.28 mm, Chamfer Distance = 0.09 +/- 0.05 mm, Mean Surface Distance (MSD) = 0.11 +/- 0.05 mm, and Root Mean Square Distance (RMSD) = 0.32 +/- 0.10 mm. Conclusion: viCT enables CT-format anatomic updating in an ESS setting without ancillary hardware. Future work will focus on fully automating registration, validation in live cases, and optimizing runtime for real-time deployment.

Figures & tables

Appendix figures & tables11 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

CardsList
  1. NeRFscopy: Neural Radiance Fields for in-vivo Time-Varying Tissues from Endoscopy

    Feb 17, 2026Laura Salort-Benejam, Antonio AgudoEndoscopic 3D Reconstruction3D Reconstruction

  2. Multimodal Shared Latent Representation of Narration, Microscope and iOCT Images for Phase Recognition in Vitreoretinal Surgery

    Aug 31, 2026Onur Izmitlioglu, Shervin Dehghani, Tarek Ghannoum +2Surgical Video UnderstandingMultimodal Contrastive Learning

  3. Deep Slice Interpolation for Reducing Through-Plane Anisotropy and Noise in Head CT

    Jun 8, 2026Luis Cortés Ferre, Miguel A. Gutiérrez-Naranjo, Marcin Balcerzyk3D Medical ImagingMedical Image Super-Resolution