An Ergonomic, Customizable Soft Robotic Glove toward Personalized Hand Rehabilitation
Authors: Rui Chen, Firman Isma Serdana, Domenico Chiaradia, Xianlong Mai, Elena Losanno, Gabriele Righi, Claudia De Santis, Federica Serra, Vincent Mendez, Cristian Camardella, Daniele Leonardis, Giulio Del Popolo, Silvestro Micera, Antonio Frisoli
Organizations: Institute of Mechanical Intelligence and Department of Excellence in Robotics and AI, Scuola Superiore Sant’Anna (SSSA), 56127, Pisa, Italy · The Biorobotics Inst. and Dept. of Excellence in Robotics and AI, Scuola Superiore Sant’Anna, Pisa, Italy · CAS Key Laboratory of Mechanical Behavior and Design of Materials, Institute of Humanoid Robots, School of Engineering Sciences, University of Science and Technology of China, Hefei, China · Modular Implantable Neuroprostheses (MINE) Laboratory, Universit`a Vita-Salute San Raffaele & Sant’Anna School of Advanced Studies, Milan, Italy · Careggi University Hospital, 50134 Florence, Italy · Bertarelli Fndn. Chair in Translational Neuroengineering, Neuro X Institute, ´Ecole Polytechnique F´ed´erale de Lausanne (EPFL), Laussane, Switzerland
Hand impairment following neurological disorders substantially limits independence in activities of daily living, motivating the development of effective assistive and rehabilitation strategies. Soft robotic gloves have attracted growing interest in this context, yet persistent challenges in customization, ergonomic fit, and user comfort constrain their clinical utility. Here, we present an ergonomic, customizable fabric-based soft robotic glove whose actuators can be tailored to individual finger-joint geometry. The glove comprises five dual-action actuators supporting finger flexion and extension, together with a dedicated thumb abduction actuator. Leveraging computer numerical control heat sealing technology, we fabricated symmetrical-chamber actuators that adopt a concave outer surface upon inflation, thereby increasing finger contact area and improving comfort. Characterization confirmed joint moment and grasping force sufficient for ADL-relevant tasks. In ten healthy subjects, active assistance significantly reduced forearm muscle activity during manipulation, and a pilot study in three individuals with cervical spinal cord injury showed more natural grasp patterns and reduced reliance on tenodesis grasp.
Figures & tables
Figure 1: Glove system overview. (A) Comparison of finger contact between single-chamber and symmetrical-chamber actuators upon inflation. (B) and (C) Design of the dual-action actuator and soft glove. (D) Complete system comprising the control box, dual-action soft glove, and smartphone web interface. (E) and (F) Glove in fully extended and fully flexed configurations, respectively.
Figure 2: Actuator design and fabrication. (A) and (B) Customized flexion and extension actuators fabricated via CNC heat sealing. (C) and (D) dual-action actuator assembly by heat sealing flexion chambers, extension chambers, and a bottom constraint layer. (E) and (F) Actuator deflection toward the target flexion and extension postures upon selective chamber inflation. (G) Thumb abduction actuator fabrication process.
Figure 3: Thumb actuator characterization. (A) Extension and flexion actuator operating configurations. (B) Moment characterization experimental setup. (C) and (D) Effects of fold angle and inflation pressure on flexion bending moment. (E) and (F) Fingertip blocking force measurement setup and results. (G) Extension actuator moment characterization setup. (H) and (I) Effects of fold angle and inflation pressure on extension bending moment.
Figure 4: Glove grasping performance characterization. (A) Directional grasp force measurement setup. (B) and (C) Directional grasp force at different inflation pressures. (D) and (E) Normal grasp force measurement configuration. (F) Normal grasp force as a function of inflation pressure. (G) Frictional grasp force measurement setup. (H) and (I) Effects of inflation pressure and cylinder diameter on frictional grasp force.
Figure 5: Protocol and results of the preliminary healthy subjects study. (A)–(C) Participants performing six transport tasks with the sEMG sleeve under three glove conditions (no glove, passive, and active). (D)–(F) Averaged sEMG amplitude across 31 active channels for Object 2, illustrating differences between conditions. (G)–(H) Mean muscle activity and task completion time across six objects under the three conditions.
Figure 6: Pilot clinical feasibility study. (A) Experimental setup for clinical testing. (B) Overview of the seven evaluation tasks. (C)–(J) Task-level results for three individuals with cervical SCI under assisted and unassisted conditions.
Soft robotic exogloves can provide hand rehabilitation and assistance. Fitting these gloves often relies on standardized measurements not tailored to the individual, limiting their effectiveness, especially for fine articulation necessary for dexterous manipulation. We present the design, fabrication, modeling, and testing of a personalized pneumatically-actuated soft robotic exoglove. The glove was fit to a user's hand with topological scans and fabricated with silicone mold casting. Finite element analysis (FEA) was performed to evaluate actuator bending and forces from physical human-robot interaction (pHRI) between an actuator and a simplified personalized biomechanical finger model. Pneumatic pressure control experiments were conducted to flex the user's finger with static and dynamic references. Fabrication results show that topological scans enable precise tailoring to hand anatomy. Simulations showed that anatomical personalization enables analysis of pHRI contact forces, and results indicate sufficient joint mobilization with non-ideal compression on the proximal phalanx. Pneumatic testing indicates that pressure control allows accurate and targeted mobility of the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints with intrinsic stiffness. Testing of multiple designs showed that relaxing the strain-limiting layer improves actuator-to-finger joint alignment during actuation. This work presents personalization to the human hand in structural conformability, joint topology, modeling of pHRI contact, and time-dependent actuation-deformation profiles. This lays the groundwork for informing exoglove design optimization to enable assistance in dexterous manipulation and neuromuscular rehabilitation of fine motor skills.
Paul Dela Cruz, Mostafa Mo. Massoud, Jacqueline Libby
Department of Mechanical Engineering, Stevens Institute of Technology, 1 Castle Point Terrace, Hoboken, NJ, 07030, USA
Hand spasticity and resulting pain affect 12 million people worldwide, including stroke survivors, arthritis patients, and those with other muscle and nerve deficiencies. Soft robotic exogloves are being introduced to help patients enhance mobility or manage pain; however, there are no current solutions that address both pain and mobility. We present preliminary development of a soft robotic exoglove that both aids in mobility and administers massage-like compression to relax spastic muscles. The glove consists of soft pneumatic actuators that are personalized to an individual's hand topology and kinematics, allowing for optimal conformability and targeted mobility. Novel soft actuators were designed, analyzed, fabricated, assembled into an exoglove, and experimentally tested. Actuators were 3D modeled and analyzed with finite element modeling under pressures of 100 and 200 kPa. Geometries were optimized to minimize stress before fabrication and testing. A dorsal finger actuator was successfully customized to a participant's hand topology, providing full conformal contact and maximal force distribution. A ventral finger actuator was successfully fabricated that can be drastically compressed in size to fit into the tight space of a hyperflexed spastic finger. A palmar actuator was successfully printed with stereolithography, showing potential for 3D-printed soft actuators with more complex geometries. The glove was assembled and successfully worn by a pilot user to validate initial findings in comfort and effectiveness.
Antonia Salluce, Maeryn Erdheim, Gailen Davis +3
Department of Mechanical Engineering, Stevens Institute of Technology, 1 Castle Point Terrace, Hoboken, NJ, 07030, USA · Faculty of Mechanical Engineering, Stevens Institute of Technology, 1 Castle Point Terrace, Hoboken, NJ, 07030, USA
Human hand grasp adaptation depends mainly on the synergy between physical structure and biological feedback. Inspired by this biomechanical principle, the Safe Thumb-Index Robotic (STIR) Hand was developed as a minimal, lightweight, and low-cost two-digit prototype featuring an asymmetric thumb-index configuration. By pairing an underactuated, tendon-driven mechanical design with flexible strain gauges embedded into silicone-encapsulated soft joints, the system achieves passive grasp adaptation while establishing both internal proprioception and external perception. Unsupervised analysis was carried out on a dataset of the STIR hand grasping 20 different objects, along with an object classification task and an ablation study to highlight the contribution of the soft joint sensors. The object classification task discriminated object size, shape, and material stiffness with a high classification accuracy. In contrast to traditional industrial grippers and robotic hands, the STIR Hand demonstrates that sensorized compliant joints significantly improve overall sensitivity and ensure safe grasping, while remaining independent of additional fingertip tactile elements or external vision systems. Finally, a comparison to similar devices grasping identical objects validates the utility of the STIR Hand.
Jonas Papenbrock, Shubhan Patni, Tomaso Lisini Baldi +4
Department of Information Engineering and Mathematics - University of Siena. · Department of Cybernetics, Faculty of Electrical Engineering, Czech Technical University in Prague