cs.CVJul 9, 2026

Pose-to-Biomechanics: Bridging 3D Human Pose Estimation and Biomechanical Attribute Prediction

Authors: Ayda EghbalianKevin Desai

Abstract

Recent progress in 3D human pose estimation has made markerless recovery of skeletal motion increasingly accurate and scalable. However, most pose estimators remain optimized for geometric keypoint accuracy, while many real-world applications in rehabilitation, sports science, ergonomics, and clinical movement analysis require biomechanical quantities that describe how the body moves, loads, and activates. In this work, we propose BioModule, a lightweight plug-in temporal transformer that attaches downstream of any 3D pose estimator and predicts biomechanical attributes from standard 17-joint 3D skeletons. BioModule is estimator-agnostic and requires no modification of the upstream pose model, enabling existing pose estimators to be extended toward physically interpretable motion analysis. To train and evaluate BioModule, we construct a large-scale aligned dataset pairing Human3.6M video and 3D keypoints with the biomechanical label space of Human3.6Mplus. We establish and verify anatomical correspondence between coordinate systems of the two datasets, enabling frame-accurate cross-modal supervision. Using this aligned supervision, BioModule predicts biomechanical quantities. We further benchmark BioModule across seven state-of-the-art 3D pose estimators, providing the first systematic analysis of how upstream pose estimation quality propagates to downstream biomechanical prediction fidelity. The results position BioModule as a compact, modular bridge between vision-based pose estimation and biomechanically meaningful human motion analysis.

Explore similar work

Aug 30, 2026cs.CV

Biomechanical 3D Body: Self-Supervised Distillation of Biomechanical Pose from a 3D Body Foundation Model

State-of-the-art monocular body recovery methods predict mesh vertices and angles on the corresponding kinematic tree, but their outputs lack biomechanically defined joint angles that downstream applications like clinical and biomechanical analyses require. We extend an existing foundation model, SAM-3D-Body, with an additional biomechanical prediction head that, from a single RGB image, regresses the joint angles and scales of a biomechanical model. Training this model presents a challenge, as there are limited datasets of paired images and biomechanical fits. To overcome this, we supervise biomechanical outputs with in-loop optimized targets from a Levenberg-Marquardt solver performing inverse kinematics fits against markers from the mesh predictions. This allows distilling the biomechanical head from the mesh head, even from unlabeled images. To make this work with GPU-optimized biomechanical models in MuJoCo, the entire model was implemented in JAX using Equinox. We trained this distilled output head on the publicly released SAM-3D-Body dataset. We then validated this model on biomechanical fits to two publicly available marker-based datasets, MoVi and BioCV, as well as movements from a clinical cohort captured with multiview markerless motion capture. The resulting model outperforms existing models for direct regression of biomechanics from images while only slightly underperforming the state-of-the-art monocular biomechanics method that performs more costly inference-time optimization of entire trajectories.
R. James Cotton, J. D. Peiffer, Lucinda Williamson +2
Nov 24, 2025cs.CV

MonoMSK: Monocular 3D Musculoskeletal Dynamics Estimation

Reconstructing biomechanically realistic 3D human motion - recovering both kinematics (motion) and kinetics (forces) - is a critical challenge. While marker-based systems are lab-bound and slow, popular monocular methods use oversimplified, anatomically inaccurate models (e.g., SMPL) and ignore physics, fundamentally limiting their biomechanical fidelity. In this work, we introduce MonoMSK, a hybrid framework that bridges data-driven learning and physics-based simulation for biomechanically realistic 3D human motion estimation from monocular video. MonoMSK jointly recovers both kinematics (motions) and kinetics (forces and torques) through an anatomically accurate musculoskeletal model. By integrating transformer-based inverse dynamics with differentiable forward kinematics and dynamics layers governed by ODE-based simulation, MonoMSK establishes a physics-regulated inverse-forward loop that enforces biomechanical causality and physical plausibility. A novel forward-inverse consistency loss further aligns motion reconstruction with the underlying kinetic reasoning. Experiments on BML-MoVi, BEDLAM, and OpenCap show that MonoMSK significantly outperforms state-of-the-art methods in kinematic accuracy, while for the first time enabling precise monocular kinetics estimation.
Farnoosh Koleini, Hongfei Xue, Ahmed Helmy +1
Aug 4, 2026cs.CV

Learning Biomechanically Plausible Human Motion from Sparse Radar Point Clouds

Radar-based human pose estimation has focused on improving learning algorithms while representing the body as unconstrained keypoint coordinates. We address the underexplored dimension of anatomical fidelity by integrating a full-body skeletal model into a differentiable, end-to-end trainable radar-based pose estimation framework, in which the pose network is supervised through forward kinematics while subject-specific geometry is fitted beforehand. Subject-specific body segment proportions are predicted from radar point cloud features to scale a biomechanical skeleton. A motion prediction network maps temporal radar sequences to generalized coordinates, and differentiable forward kinematics converts predicted joint angles into 3D positions. A contact classification loss encourages physically plausible foot-ground interaction. Under leave-one-subject-out cross-validation on 11 healthy participants performing rehabilitation exercises, the framework achieves 6.456 +/- 1.759 cm mean per-joint position error (MPJPE), 8.083 +/- 0.884 degrees mean per-joint angle error (MPJAE), 0.935 +/- 0.009 contact classification F1, and 3.4 +/- 1.3 % scaling error. This proof-of-concept study demonstrates the feasibility of recovering interpretable biomechanical descriptors from a single low-cost radar sensor in a controlled laboratory setting, a prerequisite for future clinical motion analysis.
Jonas Leo Mueller, Markus Gambietz, Alexander Weiss +2