The paper presents a numerical approach for the end-effector trajectory smoothing of a parallel robot designed for minimally invasive pancreatic surgery. The approach is tailored for real-time master-slave control architecture and uses a 3D space mouse for command input for velocity control. The trajectory smoothing is achieved by generating S-curves in the end-effector velocity fields, thus controlling the accelerations, which in turn reduces tissue trauma in the minimally invasive procedures. Real-time control is enabled by segmenting the S-curves based on the command inputs from the 3D space mouse. A special case is considered where the acceleration time is constant for all command inputs. Numeric results demonstrate stable transitions (without abrupt changes) in both the end-effector parameter space and in the active joints parameters, thereby validating the proposed approach. Further work aims to test the approach on an experimental model and integrate it into AI-based training modules.
This study develops a prescribed-time performance-shaping control method for curvature tracking of a single-segment flexible arm actuated by three antagonistic tendon pairs. A Cartesian curvature representation is introduced to avoid the undefined bending direction at the straight configuration and to establish an explicit six-tendon kinematic mapping. A cubic performance boundary contracts smoothly from an initially admissible error bound to a nonzero terminal accuracy bound within a prescribed time. Based on this boundary, a dual transformation combining static symmetric error scaling and time-varying behavior shaping maps the tracking error into a fixed unit box. The resulting controller guarantees boundary invariance, prescribed-time entry into the terminal accuracy region, and subsequent asymptotic convergence. Numerical evaluations with Python and OpenCR--MuJoCo, together with a supervised reduced-order experiment on a two-section, four-channel platform, provide complementary validation. Across six experimental trials, no violation of the prescribed boundary is observed, and the proposed controller reduces the mean terminal curvature RMSE by 32.5% relative to a matched baseline, with comparable terminal-band entry times. These results support the feasibility of the proposed approach in the reduced-order experimental setting.
A cable-driven continuum robot arm is an underactuated mechanism and may suffer residual vibration at the end of a rest-to-rest maneuver. In this work, a time-delay filter is applied as an input shaper to the system to eliminate the excitation of vibratory modes. A non-robust and a robust time-delay filter are designed based on a linear system model and demonstrate improved response compared to a velocity-driven pulse input. Experimental results using the continuum robot validate the application of the input shaper, with reduced overshoot and settling time exemplifying the reduction in oscillation at the end of the maneuver. It is also shown that utilizing the robust shaper further improves the response of the arm in comparison to applying the non-robust shaper. These results are significant towards the precise and robust implementation of continuum robots in applications involving arbitrary end-effector trajectories.
We present a MR safe, master-slave robot manipulator for abdominal interventions in the MRI chamber. A human operated 2+1-DoF master controller manipulator transmits motion and force to a 2+1-DoF slave manipulator via fluid transmission. Jointly, a digital master controller provides multimodal control capability beyond common split axis or mode switchable hybrid human-digital controller configurations found in previous studies. High input impedance, low-leakage, elastomeric fluid actuators are delegated to remote angulation control. Low-friction graphite piston cylinders are delegated to needle insertion axis remote actuation given the sub-newton force transparency and sub-millimeter motion transmission over bedside fluid piping lengths. The device enables real-time MRI guided interventions allowing manual, digital, hybrid, and collaborative control modes. Collaborative tasks such as assisted tissue penetration, fault-driven virtual fixture, and motion compensation through feedback control are presented in this paper. Preliminary MR scanner results demonstrate manipulator functional viability for an in-vivo pig experiment in bedside, manual control mode configuration.