cs.LGNov 19, 2026

Disentangling Monitor Hardware Artifacts and Smoothing Lag for Shift-Robust Intraoperative EEG and Hemodynamic Risk Calibration

Authors: Zeyu Jia

Organizations: School of Biomedical Engineering and Technology, Tianjin Medical University, No. 22 Qixiangtai Road, Heping District, Tianjin, 300070, China · Medical School, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin, 300072, China

Abstract

Commercial intraoperative electroencephalography (EEG) and blood pressure monitors introduce cyclic impedance pulses, smoothing delays, direct-current (DC) drift, and cuff holds that confound risk forecasting and uncertainty calibration. We developed a causal signal-conditioning and shift-robust conformal calibration framework across 5,439 public anesthesia procedures. Streaming filters blank 10.13-min 64-Hz impedance checks, apply unclipped post-notch conditioning, separate 63-s suppression-ratio lag, and distinguish three-channel cuff inflations from dropouts across propofol-remifentanil total intravenous anesthesia (TIVA; N = 3,214), volatile anesthesia (N = 2,046), European endoscopy sedation (N = 171), and DC-coupled surgery (N = 8). De-impedanced cortical tree ensembles were compared against deep sequence models, paired with patient-cluster Subgroup-Covariate-Weighted Conformal Risk Control (CRC) and lag-buffered online Conformal Proportional-Integral-Derivative (PID) tracking. Pre-filter blanking removed 97.90% and 97.60% of false flatline conflicts while preserving 99.23% and 98.96% of deep suppression. On unseen TIVA surgeries (N = 525), cortical features achieved area under the precision-recall curve (AUPRC) 0.3135 (1.94% prevalence) and 0.1627 (0.82% lag-free prevalence), with no detectable difference from deep encoders (p >= 0.36) and no cortical gain for hypotension (0.3432 vs. 0.3437, p = 0.784). Zero-retraining volatile transfer (N = 1,048) showed no detectable difference from an end-tidal gas oracle on lag-free suppression (0.0820 vs. 0.0736, p = 0.472). Subgroup-Covariate-Weighted CRC bounded all 70 TIVA shift cells at <= 4.38% (alpha = 5.0%) in 66.32 ms per 30-s epoch. Causal artifact disentangling and shift-aware conformal calibration support reliable real-time intraoperative risk bounds within explicit physiological observability limits.

Figures & tables

Explore similar work

CardsList
  1. Making Conformal Predictors Robust in Healthcare Settings: a Case Study on EEG Classification

    Feb 23, 2026Arjun Chatterjee, Sayeed Sajjad Razin, John Wu +3Fair Conformal PredictionConformal Prediction

  2. ReMAP: Self-supervised learning to unveil brain representations and vulnerability

    Aug 22, 2026Jade Perdereau, Virginie Loison, Kanssa El Ayeb +5ElectroencephalographyNeural Representation Geometry

  3. TrustFlow-ECG: Reliability-Aware ECG Restoration with Calibrated Risk Estimation

    Nov 21, 2026Mohamed Kamel, Tamer NadeemElectrocardiographySelective Prediction