cs.CLNov 20, 2026

Observed, Curated, Reused: Observation Bias in Clinical AI Evaluation

Authors: Md Shamim Ahmed, Lukas Galke Poech, Richard Röttger

Organizations: Department of Mathematics and Computer Science (IMADA), University of Southern Denmark, Odense, Denmark

Abstract

Clinical AI evaluations are vulnerable to observation bias embedded in routine medical documentation, which captures only what clinicians notice, test, and record rather than a complete clinical picture. As this evidence travels into publications and reference knowledge graphs, crucial distinctions disappear: unexamined symptoms blur with confirmed negatives, and chronological disease progression is lost. Surviving evidence can also enter both the benchmark query and the reference knowledge base, creating a self-referential loop where a patient is evaluated against clues derived from their own published case report. To quantify this bias, we tracked 6,503 clinical cases across six historical Human Phenotype Ontology (HPO) releases (October 2021-June 2026) to identify when HPO first cited the publications describing them. This yielded a confirmatory cohort with an observable "source ingestion" event, where HPO cited a case's source publication as target-disease evidence. Diagnostic rankers depended heavily on these source publications: for our primary semantic ranker (Resnik), publication-weighted mean reciprocal rank rose from 0.26 before paper ingestion to 0.84 upon inclusion in HPO, but collapsed to 0.05 when source-linked assertions were counterfactually removed. Two additional rankers (IC-cosine and LIRICAL) reproduced this trajectory, and control experiments confirmed the diagnostic jump was driven by the patient's publication rather than background HPO growth. Clinical AI systems may therefore score well because their knowledge base contains evidence linked to the test case's source publication, rather than through generalization. Modern knowledge is not the problem; evaluation evidence must match the claim. Trustworthy benchmarks must separate patients, source-linked evidence, and time: historical tests should use only knowledge available at the intended decision time.

Figures & tables

Explore similar work

Sep 14, 2026

KnowBench: Effort Reduction as a Unified, Deployment-Grounded Benchmark for Clinical AI

Clinical AI systems are evaluated with instruments built for research settings (reference-based similarity metrics and expert rubric panels) that measure resemblance to an artifact rather than reduction of a burden. We introduce KnowBench, pioneered by Knowtex, whose unifying metric is Effort Reduction (ER): the proportion of system-generated clinical work product accepted by the responsible clinician under expert and safety review. ER is defined once and instantiated per task across the administrative workload clinical AI automates: visit notes, diagnosis and billing codes, orders, EHR chart summarization, patient after-visit summaries, and clinical decision support. In every instantiation the construction is identical: the clinician's review-and-attestation event is the ground truth, every accepted unit is work the system completed, and every correction is residual effort returned to the clinician. The primary contribution of this paper is the benchmark itself: the metric, its degenerate cases, and a reporting protocol under which ER claims are auditable and cross-system comparable. Alongside it we report an initial headline measurement from the documentation instantiation: over one million signed encounters across a production window exceeding six months and thirteen medical specialties, Knowtex's proprietary fine-tuned clinical foundation models operating inside a closed feedback architecture achieve an aggregate ER of 97.99%, with per-specialty aggregates spanning 96.8-98.9%. This release reports the protocol's checklist partially, and states which companion statistics are withheld; the benchmark is offered so that this figure, and every figure reported after it, can be held to the same standard.
May 11, 2026

ClinicalBench: Stress-Testing Assertion-Aware Retrieval for Cross-Admission Clinical QA on MIMIC-IV

Reasoning benchmarks measure clinical performance on clean inputs. We evaluate the step before reasoning: retrieval over real EHR notes, where negation, temporality, and family-versus-patient attribution can flip a correct answer to a wrong one. EpiKG carries an assertion label and a temporality tag with every fact in a patient knowledge graph, then routes retrieval by question intent. ClinicalBench is a 400-question test over 43 MIMIC-IV patients across 9 assertion-sensitive categories. A 7-condition ablation tests each piece of EpiKG across six LLMs (Claude Opus 4.6, GPT-OSS 20B, MedGemma 27B, Gemma 4 31B, MedGemma 1.5 4B, Qwen 3.5 35B). Three physicians blindly adjudicated 100 paired items. The author-blind primary endpoint, leave-author-out paired exact McNemar on 50 unanimous-strict items rated by two external physicians, yields +22.0 percentage points (95 percent Newcombe CI [+5.1, +31.5], p=0.0192). The architectural novelty, intent-aware KG-RAG over a Contriever dense-RAG baseline (C2b to C4g_kw on the change-excluded n=362 endpoint), is +8.84 percentage points (paired McNemar p=1.79e-3); +12.43 percentage points under oracle intent. Sensitivities agree directionally: three-rater physician majority +24.0 percentage points (subject to single-author circularity); deterministic keyword reproducibility proxy +39.5 percentage points. Across the six models, the gain shrinks as the LLM-alone baseline rises (beta=-1.123, r=-0.921, p=0.009). With n=6 this looks more like regression to the mean than encoding substituting for model size. Physician adjudication identified 56 percent of auto-generated reference answers as defective, a methodological finding indicating that NLP-pipeline clinical-QA benchmarks require physician adjudication to be usable. ClinicalBench, the frozen evaluator, three-rater adjudication data, and the EpiKG output stack are publicly released.
Apr 18, 2026

The Provenance Gap in Clinical AI: Evidence-Traceable Temporal Knowledge Graphs for Rare Disease Reasoning

Frontier large language models generate clinically accurate outputs, but their citations are often fabricated. We term this the Provenance Gap. We tested five frontier LLMs across 36 clinician-validated scenarios for three rare neuromuscular disease pairs. No model produced a clinically relevant PubMed identifier without prompting. When explicitly asked to cite, the best model achieved 15.3% relevant PMIDs; the majority resolved to real publications in unrelated fields. We present HEG-TKG (Hierarchical Evidence-Grounded Temporal Knowledge Graphs), a system that grounds clinical claims in temporal knowledge graphs built from 4,512 PubMed records and curated sources with quality-tier stratification and 1,280 disease-trajectory milestones. In a controlled three-arm comparison using the same synthesis model, HEG-TKG matches baseline clinical feature coverage while achieving 100% evidence verifiability with 203 inline citations. Guideline-RAG, given overlapping source documents as raw text, produces zero verifiable citations. LLM judges cannot distinguish fabricated from verified citations without PubMed audit data. Independent clinician evaluation confirms the verifiability advantage (Cohen's d = 1.81, p < 0.001) with no degradation on safety or completeness. A counterfactual experiment shows 80% resistance to injected clinical errors with 100% detectability via citation trace. The system deploys on-premise via open-source models so patient data never leaves institutional infrastructure.