Medical QA

QA: Question Answering

Overview

Medical question answering studies how AI systems answer exam-style questions, patient inquiries, clinical queries, and multi-turn conversations, sometimes using records, images, or audio. Common approaches include retrieval-augmented generation, medical-domain fine-tuning, chain-of-thought and agent-based reasoning, and reinforcement learning with clinical rubrics. Evaluation uses multiple-choice and open-ended benchmarks such as MedQA, PubMedQA, and patient-query datasets, increasingly testing grounding, safety, calibration, multilingual ability, and performance across modalities. A central challenge is that gains on exams or automatic metrics do not guarantee accurate, unbiased, well-calibrated answers in real clinical settings, where uncertainty, missing context, and harmful errors matter.

Latest papers

98 papers16 papers in the last four weeks, up 60% on the four weeks before. 0.1% of all new papers.

Feb 26, 2026

MediX-R1: Open Ended Medical Reinforcement Learning

In this work, we introduce MediX-R1, an open-ended Reinforcement Learning (RL) framework for medical vision language models (VLMs) that enables free-form answers beyond multiple-choice formats. MediX-R1 fine-tunes a baseline vision-language backbone with Group Based RL and a composite reward tailored for medical reasoning: an LLM-based accuracy reward that judges semantic correctness with a strict YES/NO decision, a medical embedding-based semantic reward to capture paraphrases and terminology variants, and lightweight format and modality rewards that enforce interpretable reasoning and modality recognition. This multi-signal design provides stable, informative feedback for open-ended outputs where traditional verifiable or MCQ-only rewards fall short. To evaluate performance, we employ a unified evaluation framework for both text-only and multimodal (image+text) tasks that uses a Reference-based LLM-as-judge in place of brittle string-overlap metrics, capturing semantic correctness, clinical accuracy, and contextual alignment. Our results show that open-ended RL with comprehensive reward signals can effectively strengthen medical reasoning in multimodal models. Despite using only ∼51\sim51K instruction examples, MediX-R1 achieves strong performance across standard medical LLM (text-only) and VLM (image + text) benchmarks, outperforming existing open-weight medical VLMs, with large gains particularly on open-ended clinical tasks. These improvements remain consistent across multiple RL algorithms and VLM backbones and are further supported by blinded evaluations with medical experts. Our trained models, curated datasets and source code are available at https://medix.cvmbzuai.com
Feb 25, 2026

Spelling Correction in Healthcare Query-Answer Systems: Methods, Retrieval Impact, and Empirical Evaluation

Healthcare question-answering (QA) systems face a persistent challenge: users submit queries with spelling errors at rates substantially higher than those found in the professional documents they search. This paper presents the first controlled study of spelling correction as a retrieval preprocessing step in healthcare QA using real consumer queries. We conduct an error census across two public datasets -- the TREC 2017 LiveQA Medical track (104 consumer health questions) and HealthSearchQA (4,436 health queries from Google autocomplete) -- finding that 61.5% of real medical queries contain at least one spelling error, with a token-level error rate of 11.0%. We evaluate four correction methods -- conservative edit distance, standard edit distance (Levenshtein), context-aware candidate ranking, and SymSpell -- across three experimental conditions: uncorrected queries against an uncorrected corpus (baseline), uncorrected queries against a corrected corpus, and fully corrected queries against a corrected corpus. Using BM25 and TF-IDF cosine retrieval over 1,935 MedQuAD answer passages with TREC relevance judgments, we find that query correction substantially improves retrieval -- edit distance and context-aware correction achieve MRR improvements of +9.2% and NDCG@10 improvements of +8.3% over the uncorrected baseline. Critically, correcting only the corpus without correcting queries yields minimal improvement (+0.5% MRR), confirming that query-side correction is the key intervention. We complement these results with a 100-sample error analysis categorising correction outcomes per method and provide evidence-based recommendations for practitioners.
Feb 16, 2026

Assessing Large Language Models for Medical QA: Zero-Shot and LLM-as-a-Judge Evaluation

Recently, Large Language Models (LLMs) have gained significant traction in medical domain, especially in developing a QA systems to Medical QA systems for enhancing access to healthcare in low-resourced settings. This paper compares five LLMs deployed between April 2024 and August 2025 for medical QA, using the iCliniq dataset, containing 38,000 medical questions and answers of diverse specialties. Our models include Llama-3-8B-Instruct, Llama 3.2 3B, Llama 3.3 70B Instruct, Llama-4-Maverick-17B-128E-Instruct, and GPT-5-mini. We are using a zero-shot evaluation methodology and using BLEU and ROUGE metrics to evaluate performance without specialized fine-tuning. Our results show that larger models like Llama 3.3 70B Instruct outperform smaller models, consistent with observed scaling benefits in clinical tasks. It is notable that, Llama-4-Maverick-17B exhibited more competitive results, thus highlighting evasion efficiency trade-offs relevant for practical deployment. These findings align with advancements in LLM capabilities toward professional-level medical reasoning and reflect the increasing feasibility of LLM-supported QA systems in the real clinical environments. This benchmark aims to serve as a standardized setting for future study to minimize model size, computational resources and to maximize clinical utility in medical NLP applications.
Feb 4, 2026

RA-QA: A Benchmarking System for Respiratory Audio Question Answering Under Real-World Heterogeneity

As conversational multimodal AI tools are increasingly adopted to process patient data for health assessment, robust benchmarks are needed to measure progress and expose failure modes under realistic conditions. Despite the importance of respiratory audio for mobile health screening, respiratory audio question answering remains underexplored, with existing studies evaluated narrowly and lacking real-world heterogeneity across modalities, devices, and question types. We hence introduce the Respiratory-Audio Question-Answering (RA-QA) benchmark, including a standardized data generation pipeline, a comprehensive multimodal QA collection, and a unified evaluation protocol. RA-QA harmonizes public RA datasets into a collection of 9 million format-diverse QA pairs covering diagnostic and contextual attributes. We benchmark general audio-language models as well as domain-specific architectures, establishing reproducible reference points and showing how current approaches fail under heterogeneity.
Dec 26, 2025

Safety boundary maintenance in consumer AI systems responding to pediatric health queries: a cross-platform benchmark evaluation under naturalistic and adversarially pressured conditions

Consumer artificial intelligence chatbots are now accessed by hundreds of millions of users seeking health information, yet systematic evaluation of their safety boundary maintenance under real-world caregiver pressure remains scarce. We evaluated PediatricSafetyBench-v2, a benchmark of 600 pediatrics health queries comprising 300 authentic caregiver queries sourced from the HealthCareMagic-100k-en physician consultation corpus and 300 matched adversarial variants incorporating six operationalized caregiver pressure patterns, across four consumer AI systems (GPT-4o-mini, Gemini-2.0-Flash, Claude-3.5-Haiku, and Llama-3.1-8B). Safety boundary maintenance was assessed using a validated five-component Safety Composite Score (maximum 15 points; safety-appropriate threshold of 10 or above), validated against independent human raters prior to full-corpus application (mean weighted kappa 0.76; Pearson r = 0.88). The overall safety-appropriate rate was 95.5%. Safety-oriented system prompt deployment improved safety-appropriate rates by 5.9 percentage points across all four models. Counter-intuitively, adversarial caregiver pressure was associated with higher rather than lower Safety Composite Score values for all four models across all ten topic categories and severity levels. False expertise claims were the most vulnerability-inducing pressure pattern, whereas emotional escalation was associated with the highest scores. Consumer AI systems maintain safety boundaries in the large majority of pediatrics health interactions. PediatricSafetyBench-v2 is publicly released for longitudinal safety monitoring.
Dec 5, 2025

Multilingual Medical Reasoning for Question Answering with Large Language Models

Large Language Models (LLMs) with reasoning capabilities have recently demonstrated strong potential in medical Question Answering (QA). Existing approaches are largely English-focused and primarily rely on distillation from general-purpose LLMs, raising concerns about the reliability of their medical knowledge. In this work, we present a method to generate multilingual reasoning traces based on medical knowledge extracted from Wikipedia. We produce 500k traces in English, Italian, and Spanish, using a retrieval-augmented generation approach over medical information from Wikipedia. The traces are generated to solve medical questions drawn from MedQA and MedMCQA, which we extend to Italian and Spanish. We test our pipeline in both in-domain and out-of-domain settings across Medical QA benchmarks, and demonstrate that our reasoning traces improve performance both when utilized via in-context learning (few-shot) and supervised fine-tuning, yielding state-of-the-art results among 8B-parameter LLMs. We believe that these resources can support the development of more transparent clinical decision-support tools in multilingual settings. We release the full suite of resources: reasoning traces, translated QA datasets, Medical-Wikipedia, and fine-tuned models.
Aug 31, 2025

RPRO: Ranked Preference Reinforcement Optimization for Enhancing Medical QA and Diagnostic Reasoning

Medical question answering requires advanced reasoning that integrates domain knowledge with logical inference. However, existing large language models (LLMs) often generate reasoning chains that lack factual accuracy and clinical reliability. We propose Ranked Preference Reinforcement Optimization (RPRO), a novel framework that combines reinforcement learning with preference-driven reasoning refinement to enhance clinical chain-of-thought (CoT) performance. RPRO distinguishes itself from prior approaches by employing task-adaptive reasoning templates and a probabilistic evaluation mechanism that aligns model outputs with established clinical workflows, while automatically identifying and correcting low-quality reasoning chains. Unlike traditional pairwise preference methods, RPRO introduces a groupwise ranking optimization based on the Bradley--Terry model and incorporates KL-divergence regularization for stable training. Experiments on PubMedQA, MedQA-USMLE, and a real-world clinical dataset from Far Eastern Memorial Hospital (FEMH) demonstrate consistent improvements over strong baselines. Remarkably, our 2B-parameter model outperforms much larger 7B--20B models, including medical-specialized variants. These findings demonstrate that combining preference optimization with quality-driven refinement provides a scalable and clinically grounded approach to building more reliable medical LLMs.
Mar 7, 2024

Few shot chain-of-thought driven reasoning to prompt LLMs for open ended medical question answering

In this paper, we propose a modified version of the MedQA-USMLE dataset, named MEDQA-OPEN, which contains open-ended medical questions without options to mimic clinical scenarios, along with clinician-approved reasoned answers. Additionally, we implement a prompt driven by Chain of Thought (CoT) reasoning, CLINICR, to mirror the prospective process of incremental reasoning, reaching a correct response to medical questions. We empirically demonstrate how CLINICR outperforms the state-of-the-art 5-shot CoT-based prompt (Liévin et al., 2022). We also present an approach that mirrors real-life clinical practice by first exploring multiple differential diagnoses through MCQ-CLINICR and subsequently narrowing down to a final diagnosis using MCQ-ELIMINATIVE. Finally, emphasizing the importance of response verification in medical settings, we utilize a reward model mechanism, replacing the elimination process performed by MCQ-ELIMINATIVE.