Disentangling Monitor Hardware Artifacts and Smoothing Lag for Shift-Robust Intraoperative EEG and Hemodynamic Risk Calibration

Authors: Zeyu Jia

Organizations: School of Biomedical Engineering and Technology, Tianjin Medical University, No. 22 Qixiangtai Road, Heping District, Tianjin, 300070, China · Medical School, Tianjin University, No. 92 Weijin Road, Nankai District, Tianjin, 300072, China

Abstract

Commercial intraoperative electroencephalography (EEG) and blood pressure monitors introduce cyclic impedance pulses, smoothing delays, direct-current (DC) drift, and cuff holds that confound risk forecasting and uncertainty calibration. We developed a causal signal-conditioning and shift-robust conformal calibration framework across 5,439 public anesthesia procedures. Streaming filters blank 10.13-min 64-Hz impedance checks, apply unclipped post-notch conditioning, separate 63-s suppression-ratio lag, and distinguish three-channel cuff inflations from dropouts across propofol-remifentanil total intravenous anesthesia (TIVA; N = 3,214), volatile anesthesia (N = 2,046), European endoscopy sedation (N = 171), and DC-coupled surgery (N = 8). De-impedanced cortical tree ensembles were compared against deep sequence models, paired with patient-cluster Subgroup-Covariate-Weighted Conformal Risk Control (CRC) and lag-buffered online Conformal Proportional-Integral-Derivative (PID) tracking. Pre-filter blanking removed 97.90% and 97.60% of false flatline conflicts while preserving 99.23% and 98.96% of deep suppression. On unseen TIVA surgeries (N = 525), cortical features achieved area under the precision-recall curve (AUPRC) 0.3135 (1.94% prevalence) and 0.1627 (0.82% lag-free prevalence), with no detectable difference from deep encoders (p >= 0.36) and no cortical gain for hypotension (0.3432 vs. 0.3437, p = 0.784). Zero-retraining volatile transfer (N = 1,048) showed no detectable difference from an end-tidal gas oracle on lag-free suppression (0.0820 vs. 0.0736, p = 0.472). Subgroup-Covariate-Weighted CRC bounded all 70 TIVA shift cells at <= 4.38% (alpha = 5.0%) in 66.32 ms per 30-s epoch. Causal artifact disentangling and shift-aware conformal calibration support reliable real-time intraoperative risk bounds within explicit physiological observability limits.

Figures & tables

Explore similar work

Feb 23, 2026

Making Conformal Predictors Robust in Healthcare Settings: a Case Study on EEG Classification

Quantifying uncertainty in clinical predictions is critical for high-stakes diagnosis tasks. Conformal prediction offers a principled approach by providing prediction sets with theoretical coverage guarantees. However, in practice, patient distribution shifts violate the i.i.d. assumptions underlying standard conformal methods, leading to poor coverage in healthcare settings. In this work, we evaluate several conformal prediction approaches on EEG seizure classification, a task with known distribution shift challenges and label uncertainty. We demonstrate that personalized calibration strategies can improve coverage by over 20 percentage points while maintaining comparable prediction set sizes. Our implementation is available via PyHealth, an open-source healthcare AI framework: https://github.com/sunlabuiuc/PyHealth.
Aug 22, 2026

ReMAP: Self-supervised learning to unveil brain representations and vulnerability

General anesthesia offers a rare opportunity to observe the human brain under a standardized, controlled perturbation. Yet intraoperative electroencephalography (EEG) is almost always reduced to a single proprietary depth index, collapsing a rich trajectory into one number and discarding how a brain moves between states. Here we ask whether the geometry of that trajectory, not merely the depth it reaches, carries clinically meaningful information. Using similarity-based self-supervised learning on raw, two-electrode frontal EEG, with no labels, we place each recording within a low-dimensional space in which anesthetic depth becomes one readable axis while the shape of a patient's path encodes additional structure. We validate the representation across two cohorts and two acquisition systems totaling more than 1,000 patients. Depth of anesthesia is predicted accurately (BIS mean absolute error = 3.2, R2 = 0.82), and in the sparse-montage setting our compact ( 68k parameter) model remains competitive with EEG foundation models orders of magnitude larger (4M-157M parameters), indicating that matching the representation to the recording dominates raw scale. The learned space organizes age along its own gradient, independent from depth, without supervision. The same space also aligns with interpretable anesthetic signatures like frontal alpha, slow-delta, and burst suppression, linking this data-driven representation to established neurophysiology. On an independent cohort with longitudinal follow-up, the geometry of the early trajectory separates 30- month cognitive and mortality outcomes complementary to age (AUROC 0.86). These results suggest that the path a brain traces through anesthesia is a label-efficient correlate of latent vulnerability, motivating prospective validation.
Nov 21, 2026

TrustFlow-ECG: Reliability-Aware ECG Restoration with Calibrated Risk Estimation

Electrocardiogram (ECG) restoration models can reduce noise and motion artifacts, but they rarely estimate whether the restored waveform is reliable for downstream analysis. We propose TrustFlow-ECG, a reliability-aware restoration framework that combines a one-step conditional rectified-flow restorer with a lightweight window-level risk predictor. The predictor uses the noisy ECG, restored ECG, and correction residual, then applies validation-set isotonic calibration for selective ECG analysis. We evaluate on MIT-BIH ECG windows corrupted with NSTDB artifacts, powerline interference, and mixed noise across multiple SNRs, with an external 9,675-window PTB-XL stress check without retraining. TrustFlow achieves 0.862 Spearman correlation with true risk and 0.911 AUROC for failure detection, while calibration reduces ECE from 0.0385 to 0.0098. At 80% coverage, selective rejection reduces RMSE from 0.1848 to 0.1345, improves R-peak F1 from 0.8778 to 0.9175, and reduces HR MAE from 6.26 to 4.88 bpm.