Accelerated MRI Reconstruction

MRI: Magnetic Resonance Imaging

Overview

The field studies how to reconstruct MRI images from fewer k-space measurements, reducing scan time while retaining structures and signals needed for diagnosis. Methods range from compressed sensing and parallel-coil models to unrolled networks, implicit neural representations, and diffusion or flow-based priors, often enforcing consistency with acquired measurements. Researchers also learn acquisition patterns and develop techniques for dynamic, multi-contrast, low-field, and motion-affected MRI. A central challenge is balancing speed and image quality with generalization across scanners and patients, while detecting hallucinations and estimating when a reconstruction is unreliable.

Latest papers

85 papers10 papers in the last four weeks, up 11% on the four weeks before. 0.1% of all new papers.

Apr 14, 2026

Information-Theoretic Optimization for Task-Adapted Compressed Sensing Magnetic Resonance Imaging

Task-adapted compressed sensing magnetic resonance imaging (CS-MRI) is emerging to address the specific demands of downstream clinical tasks with significantly fewer k-space measurements than required by Nyquist sampling. However, existing task-adapted CS-MRI methods suffer from the uncertainty problem for medical diagnosis and cannot achieve adaptive sampling in end-to-end optimization with reconstruction or clinical tasks. To address these limitations, we propose the first task-adapted CS-MRI from the information-theoretic perspective to simultaneously achieve probabilistic inference for uncertainty prediction and adapt to arbitrary sampling ratios and versatile clinical applications. Specifically, we formalize the task-adapted CS-MRI optimization problem by maximizing the mutual information between undersampled k-space measurements and clinical tasks to enable probabilistic inference for addressing the uncertainty problem. We leverage amortized optimization and construct tractable variational bounds for mutual information to jointly optimize sampling, reconstruction, and task-inference models, which enables flexible sampling ratio control using a single end-to-end trained model. Furthermore, the proposed framework addresses two kinds of distinct clinical scenarios within a unified approach, i.e., i) joint task and reconstruction, where reconstruction serves as an auxiliary process to enhance task performance; and ii) task implementation with suppressed reconstruction, applicable for privacy protection. Extensive experiments on large-scale MRI datasets demonstrate that the proposed framework achieves highly competitive performance on standard metrics like Dice compared to deterministic counterpart but provides better distribution matching to the ground-truth posterior distribution as measured by the generalized energy distance (GED).
Apr 13, 2026

MosaicMRI: A Diverse Dataset and Benchmark for Raw Musculoskeletal MRI

Deep learning underpins a wide range of applications in MRI, including reconstruction, artifact removal, and segmentation. However, progress has been driven largely by public datasets focused on brain and knee imaging, shaping how models are trained and evaluated. As a result, careful studies of the reliability of these models across diverse anatomical settings remain limited. In this work, we introduce MosaicMRI, a large and diverse collection of fully sampled raw musculoskeletal (MSK) MR measurements designed for training and evaluating machine-learning--based methods. MosaicMRI is the largest open-source raw MSK MRI dataset to date, comprising 3,150 volumes and 89,830 slices, including a 3,096-volume 1.5T core dataset and a 54-volume 0.55T low-field set. The dataset offers substantial diversity in volume orientation (e.g., axial, sagittal), imaging contrasts (e.g., PD, T1, T2), anatomies (e.g., spine, knee, hip, ankle, and others), numbers of acquisition coils, and field strengths. Using accelerated reconstruction as a testbed, we study scaling, robustness, and data selection under realistic MSK distribution shifts. Across E2E-VarNet, U-Net, and ViT baselines, mixed-anatomy training improves over anatomy-specific training, showing that the benefit of anatomical diversity is not architecture-specific. Zero-shot experiments on the 0.55~T low-field set highlight that using more training data improves average reconstruction under field-strength shift. Controlled subset experiments further suggest that these gains come from transferable cross-anatomy structure, rather than anatomy or contrast matching alone.
Apr 9, 2026

PSIRNet: Deep Learning-based Free-breathing Rapid Acquisition Late Enhancement Imaging

Purpose: To develop and evaluate a deep learning (DL) method for free-breathing phase-sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) cardiac MRI that produces diagnostic-quality images from a single acquisition over two heartbeats, eliminating the need for 8 to 24 motion-corrected (MOCO) signal averages. Materials and Methods: Raw data comprising 800,653 slices from 55,917 patients, acquired on 1.5T and 3T scanners across multiple sites from 2016 to 2024, were used in this retrospective study. Data were split by patient: 640,000 slices (42,822 patients) for training and the remainder for validation and testing, without overlap. The training and testing data were from different institutions. PSIRNet, a physics-guided DL network with 845 million parameters, was trained end-to-end to reconstruct PSIR images with surface coil correction from a single interleaved IR/PD acquisition over two heartbeats. Reconstruction quality was evaluated using SSIM, PSNR, and NRMSE against MOCO PSIR references. Two expert cardiologists performed an independent qualitative assessment, scoring image quality on a 5-point Likert scale across bright blood, dark blood, and wideband LGE variants. Paired superiority and equivalence (margin = 0.25 Likert points) were tested using exact Wilcoxon signed-rank tests at a significance level of 0.05 using R version 4.5.2. Results: Both readers rated single-average PSIRNet reconstructions superior to MOCO PSIR for dark blood LGE (conservative P = .002); for bright blood and wideband, one reader rated it superior and the other confirmed equivalence (all P < .001). Inference required approximately 100 msec per slice versus more than 5 sec for MOCO PSIR. Conclusion: PSIRNet produces diagnostic-quality free-breathing PSIR LGE images from a single acquisition, enabling 8- to 24-fold reduction in acquisition time.
Apr 8, 2026

Vision-Language Model-Guided Deep Unrolling Enables Personalized, Fast MRI

Magnetic Resonance Imaging (MRI) is a cornerstone in medicine and healthcare but suffers from long acquisition times. Traditional accelerated MRI methods optimize for generic image quality, lacking adaptability for specific clinical tasks. To address this, we introduce PASS (Personalized, Anomaly-aware Sampling and reconStruction), an intelligent MRI framework that leverages a Vision-Language Model (VLM) to guide a deep unrolling network for task-oriented, fast imaging. PASS dynamically personalizes the imaging pipeline through three core contributions: (1) a deep unrolled reconstruction network derived from a physics-based MRI model; (2) a sampling module that generates patient-specific kk-space trajectories; and (3) an anomaly-aware prior, extracted from a pretrained VLM, which steers both sampling and reconstruction toward clinically relevant regions. By integrating the high-level clinical reasoning of a VLM with an interpretable, physics-aware network, PASS achieves superior image quality across diverse anatomies, contrasts, anomalies, and acceleration factors. This enhancement directly translates to improvements in downstream diagnostic tasks, including fine-grained anomaly detection, localization, and diagnosis.
Mar 31, 2026

Training deep learning based dynamic MR image reconstruction using synthetic fractals

Purpose: To investigate whether synthetically generated fractal data can be used to train deep learning (DL) models for dynamic MRI reconstruction, thereby avoiding the privacy, licensing, and availability limitations associated with cardiac MR training datasets. Methods: A training dataset was generated using quaternion Julia fractals to produce 2D+time images. Multi-coil MRI acquisition was simulated to generate paired fully sampled and radially undersampled k-space data. A 3D UNet deep artefact suppression model was trained using these fractal data (F-DL) and compared with an identical model trained on cardiac MRI data (CMR-DL). Both models were evaluated on prospectively acquired radial real-time cardiac MRI from 10 patients. Reconstructions were compared against compressed sensing(CS) and low-rank deep image prior (LR-DIP). All reconstrctuions were ranked for image quality, while ventricular volumes and ejection fraction were compared with reference breath-hold cine MRI. Results: There was no significant difference in qualitative ranking between F-DL and CMR-DL (p=0.9), while both outperformed CS and LR-DIP (p<0.001). Ventricular volumes and function derived from F-DL were similar to CMR-DL, showing no significant bias and accptable limits of agreement compared to reference cine imaging. However, LR-DIP had a signifcant bias (p=0.016) and wider lmits of agreement. Conclusion: DL models trained using synthetic fractal data can reconstruct real-time cardiac MRI with image quality and clinical measurements comparable to models trained on true cardiac MRI data. Fractal training data provide an open, scalable alternative to clinical datasets and may enable development of more generalisable DL reconstruction models for dynamic MRI.
Mar 28, 2026

Weakly Convex Ridge Regularization for 3D Non-Cartesian MRI Reconstruction

While highly accelerated non-Cartesian acquisition protocols significantly reduce scan time, they often entail long reconstruction delays. Deep learning based reconstruction methods can alleviate this, but often lack stability and robustness to distribution shifts. As an alternative, we train a rotation invariant weakly convex ridge regularizer (WCRR). The resulting variational reconstruction approach is benchmarked against state of the art methods on retrospectively simulated data and (out of distribution) on prospective GoLF SPARKLING and CAIPIRINHA acquisitions. Our approach consistently outperforms widely used baselines and achieves performance comparable to Plug and Play reconstruction with a state of the art 3D DRUNet denoiser, while offering substantially improved computational efficiency and robustness to acquisition changes. In summary, WCRR unifies the strengths of principled variational methods and modern deep learning based approaches.
Mar 23, 2026

Anatomical Token Uncertainty for Transformer-Guided Active MRI Acquisition

Full data acquisition in MRI is inherently slow, which limits clinical throughput and increases patient discomfort. Compressed Sensing MRI (CS-MRI) seeks to accelerate acquisition by reconstructing images from under-sampled k-space data, requiring both an optimal sampling trajectory and a high-fidelity reconstruction model. In this work, we propose a novel active sampling framework that leverages the inherent discrete structure of a pretrained medical image tokenizer and a latent transformer. By representing anatomy through a dictionary of quantized visual tokens, the model provides a well-defined probability distribution over the latent space. We utilize this distribution to derive a principled uncertainty measure via token entropy, which guides the active sampling process. We introduce two strategies to exploit this latent uncertainty: (1) Latent Entropy Selection (LES), projecting patch-wise token entropy into the kk-space domain to identify informative sampling lines, and (2) Gradient-based Entropy Optimization (GEO), which identifies regions of maximum uncertainty reduction via the kk-space gradient of a total latent entropy loss. We evaluate our framework on the fastMRI singlecoil Knee and Brain datasets at ×8\times 8 and ×16\times 16 acceleration. Our results demonstrate that our active policies outperform state-of-the-art baselines in perceptual metrics, and feature-based distances. Our code is available at https://github.com/levayz/TRUST-MRI.
Mar 19, 2026

UEPS: Robust and Efficient MRI Reconstruction

Deep unrolled models (DUM) have become the state-of-the-art for accelerated MRI reconstruction, yet their robustness under domain shift remains a critical barrier to clinical adoption. In this work, we identify coil sensitivity map (CSM) estimation as the primary bottleneck limiting generalization. To address this, we propose UEPS, a novel DUM architecture featuring three key designs: (i) an Unrolled Expanded (UE) design that eliminates CSM dependency by reconstructing each coil independently; (ii) progressive resolution, which leverages k-space-to-image mapping for efficient coarse-to-fine refinement; and (iii) sparse attention tailored to MRI's 1D undersampling nature. These physics-grounded designs enable gains in robustness and computational efficiency. We construct a large-scale zero-shot transfer benchmark comprising 10 out-of-distribution (OOD) test sets spanning diverse clinical shifts, anatomy, view, contrast, vendor, field strength, and coil configurations. Extensive experiments demonstrate that UEPS consistently and substantially outperforms existing DUM, end-to-end, diffusion, and untrained methods across all OOD tests, achieving state-of-the-art robustness with low-latency inference suitable for real-time deployment.
Mar 18, 2026

Unrolled Reconstruction with Integrated Super-Resolution for Accelerated 3D LGE MRI

Accelerated 3D late gadolinium enhancement (LGE) MRI requires robust reconstruction methods to recover thin atrial structures from undersampled k-space data. While unrolled model-based networks effectively integrate physics-driven data consistency with learned priors, they operate at the acquired resolution and may fail to fully recover high-frequency detail. We propose a hybrid unrolled reconstruction framework in which an Enhanced Deep Super-Resolution (EDSR) network replaces the proximal operator within each iteration of the optimization loop, enabling joint super-resolution enhancement and data consistency enforcement. The model is trained end-to-end on retrospectively undersampled preclinical 3D LGE datasets and compared against compressed sensing, Model-Based Deep Learning (MoDL), and self-guided Deep Image Prior (DIP) baselines. Across acceleration factors, the proposed method consistently improves PSNR and SSIM over standard unrolled reconstruction and better preserves fine cardiac structures, leading to improved LA (left atrium) segmentation performance. These results demonstrate that integrating super-resolution priors directly within model-based reconstruction provides measurable gains in accelerated 3D LGE MRI.
Mar 14, 2026

Low-Field Magnetic Resonance Image Enhancement using Undersampled k-Space

Low-field magnetic resonance imaging (MRI) offers a cost-effective alternative for medical imaging in resource-limited settings. However, its widespread adoption is hindered by two key challenges: prolonged scan times and reduced image quality. Accelerated acquisition can be achieved using k-space undersampling, while image enhancement traditionally relies on spatial-domain postprocessing. In this work, we propose a novel deep learning framework based on a U-Net variant that operates directly in k-space to super-resolve low-field MR images directly using undersampled data while quantifying the impact of reduced k-space sampling. Unlike conventional approaches that treat image super-resolution as a postprocessing step following image reconstruction from undersampled k-space, our unified model integrates both processes, leveraging k-space information to achieve superior image fidelity. Extensive experiments on synthetic and real low-field brain MRI datasets demonstrate that k-space-driven image super-resolution outperforms conventional spatial-domain counterparts. Furthermore, our results show that undersampled k-space reconstructions achieve comparable quality to full k-space acquisitions, enabling substantial scan-time acceleration without compromising diagnostic utility.
Mar 14, 2026

Low-Field Magnetic Resonance Image Quality Enhancement using Undersampled k-Space and Out-of-Distribution Generalisation

Low-field magnetic resonance imaging (MRI) offers affordable access to diagnostic imaging but faces challenges such as prolonged acquisition times and reduced image quality. Although accelerated imaging via k-space undersampling helps reduce scan time, image quality enhancement methods often rely on spatial-domain postprocessing. Deep learning achieved state-of-the-art results in both domains. However, most models are trained and evaluated using in-distribution (InD) data, creating a significant gap in understanding model performance when tested using out-of-distribution (OOD) data. To address these issues, we propose a novel framework that reconstructs high-field-like MR images directly from undersampled low-field MRI k-space, quantifies the impact of reduced sampling, and evaluates the generalisability of the model using OOD. Our approach utilises a k-space dual channel U-Net to jointly process the real and imaginary components of undersampled k-space, restoring missing frequency content, and incorporates an ensemble strategy to generate uncertainty maps. Experiments on low-field brain MRI demonstrate that our k-space-driven image quality enhancement outperforms the counterpart spatial-domain and other state-of-the-art baselines, achieving image quality comparable to full high-field k-space acquisitions using OOD data. To the best of our knowledge, this work is among the first to combine low-field MR image reconstruction, quality enhancement using undersampled k-space, and uncertainty quantification within a unified framework.
Mar 13, 2026

Open World MRI Reconstruction with Bias-Calibrated Adaptation

Real-world MRI reconstruction systems face the open-world challenge: test data from unseen imaging centers, anatomical structures, or acquisition protocols can differ drastically from training data, causing severe performance degradation. Existing methods struggle with this challenge. To address this, we propose BiasRecon, a bias-calibrated adaptation framework grounded in the minimal intervention principle: preserve what transfers, calibrate what does not. Concretely, BiasRecon formulates open-world adaptation as an alternating optimization framework that jointly optimizes three components: (1) frequency-guided prior calibration that introduces layer-wise calibration variables to selectively modulate frequency-specific features of the pre-trained score network via self-supervised k-space signals, (2) score-based denoising that leverages the calibrated generative prior for high-fidelity image reconstruction, and (3) adaptive regularization that employs Stein's Unbiased Risk Estimator to dynamically balance the prior-measurement trade-off, matching test-time noise characteristics without requiring ground truth. By intervening minimally and precisely through this alternating scheme, BiasRecon achieves robust adaptation with fewer than 100 tunable parameters. Extensive experiments across four datasets demonstrate state-of-the-art performance on open-world reconstruction tasks.
Mar 13, 2026

Accelerating Stroke MRI with Diffusion Probabilistic Models through Large-Scale Pre-training and Target-Specific Fine-Tuning

Purpose: To develop a data-efficient strategy for accelerated MRI reconstruction with Diffusion Probabilistic Generative Models (DPMs) that enables faster scan times in clinical stroke MRI when only limited fully-sampled data samples are available. Methods: Our simple training strategy, inspired by the foundation model paradigm, first trains a DPM on a large, diverse collection of publicly available brain MRI data in fastMRI and then fine-tunes on a small dataset from the target application using carefully selected learning rates and fine-tuning durations. The approach is evaluated on controlled fastMRI experiments and on clinical stroke MRI data with a blinded clinical reader study. Results: DPMs pre-trained on approximately 4000 subjects with non-FLAIR contrasts and fine-tuned on FLAIR data from only 20 target subjects achieve reconstruction performance comparable to models trained with substantially more target-domain FLAIR data across multiple acceleration factors. Experiments reveal that moderate fine-tuning with a reduced learning rate yields improved performance, while insufficient or excessive fine-tuning degrades reconstruction quality. When applied to clinical stroke MRI, a blinded reader study involving two neuroradiologists indicates that images reconstructed using the proposed approach from 2×2 \times accelerated data are non-inferior to standard-of-care in terms of image quality and structural delineation. Conclusion: Large-scale pre-training combined with targeted fine-tuning enables DPM-based MRI reconstruction in data-constrained, accelerated clinical stroke MRI. The proposed approach substantially reduces the need for large application-specific datasets while maintaining clinically acceptable image quality, supporting the use of foundation-inspired diffusion models for accelerated MRI in targeted applications.
Mar 13, 2026

Bayesian Uncertainty-Aware MRI Reconstruction

We propose a novel framework for joint magnetic resonance image reconstruction and uncertainty quantification using under-sampled k-space measurements. The problem is formulated as a Bayesian linear inverse problem, where prior distributions are assigned to the unknown model parameters. Specifically, we assume the target image is sparse in its spatial gradient and impose a total variation prior model. A Markov chain Monte Carlo (MCMC) method, based on a split-and-augmented Gibbs sampler, is then used to sample from the resulting joint posterior distribution of the unknown parameters. Experiments conducted using single- and multi-coil datasets demonstrate the superior performance of the proposed framework over optimisation-based compressed sensing algorithms. Additionally, our framework effectively quantifies uncertainty, showing strong correlation with error maps computed from reconstructed and ground-truth images.
Mar 11, 2026

MRI2Qmap: multi-parametric quantitative mapping with MRI-driven denoising priors

Magnetic Resonance Fingerprinting (MRF) and other highly accelerated transient-state parameter mapping techniques enable simultaneous quantification of multiple tissue properties, but often suffer from aliasing artifacts due to compressed sampling. Incorporating spatial image priors can mitigate these artifacts, and deep learning has shown strong potential when large training datasets are available. However, extending this paradigm to MRF-type sequences remains challenging due to the scarcity of quantitative imaging data for training. Can this limitation be overcome by leveraging sources of training data from clinically-routine weighted MRI images? To this end, we introduce MRI2Qmap, a plug-and-play quantitative reconstruction framework that integrates the physical acquisition model with priors learned from deep denoising autoencoders pretrained on large multimodal weighted-MRI datasets. MRI2Qmap demonstrates that spatial-domain structural priors learned from independently acquired datasets of routine weighted-MRI images can be effectively used for quantitative MRI reconstruction. The proposed method is validated on highly accelerated 3D whole-brain MRF data from both in-vivo and simulated acquisitions, achieving competitive or superior performance relative to existing baselines without requiring ground-truth quantitative imaging data for training. By decoupling quantitative reconstruction from the need for ground-truth MRF training data, this framework points toward a scalable paradigm for quantitative MRI that can capitalize on the large and growing repositories of routine clinical MRI.
Mar 8, 2026

Transferable Optimization Network for Cross-Domain Image Reconstruction

We develop a novel transfer learning framework to tackle the challenge of limited training data in image reconstruction problems. The proposed framework consists of two training steps, both of which are formed as bi-level optimizations. In the first step, we train a powerful universal feature-extractor that is capable of learning important knowledge from large, heterogeneous data sets in various domains. In the second step, we train a task-specific domain-adapter for a new target domain or task with only a limited amount of data available for training. Then the composition of the adapter and the universal feature-extractor effectively explores feature which serve as an important component of image regularization for the new domains, and this leads to high-quality reconstruction despite the data limitation issue. We apply this framework to reconstruct under-sampled MR images with limited data by using a collection of diverse data samples from different domains, such as images of other anatomies, measurements of various sampling ratios, and even different image modalities, including natural images. Experimental results demonstrate a promising transfer learning capability of the proposed method.
Mar 5, 2026

Gabor Primitives for Accelerated Cardiac Cine MRI Reconstruction

Accelerated cardiac cine MRI requires reconstructing spatiotemporal images from highly undersampled k-space data. Implicit neural representations (INRs) enable scan-specific reconstruction without large training datasets, but encode content implicitly in network weights without physically interpretable parameters. Gaussian primitives provide an explicit and geometrically interpretable alternative, but their spectra are confined near the k-space origin, limiting high-frequency representation. We propose Gabor primitives for MRI reconstruction, modulating each Gaussian envelope with a complex exponential to place its spectral support at an arbitrary k-space location, enabling efficient representation of both smooth structures and sharp boundaries. To exploit spatiotemporal redundancy in cardiac cine, we decompose per-primitive temporal variation into a low-rank geometry basis capturing cardiac motion and a signal-intensity basis modeling contrast changes. Experiments on cardiac cine data with Cartesian and radial trajectories show that Gabor primitives consistently outperform compressed sensing, Gaussian primitives, and hash-grid INR baselines, while providing a compact, continuous-resolution representation with physically meaningful parameters.
Mar 4, 2026

MPFlow: Multi-modal Posterior-Guided Flow Matching for Zero-Shot MRI Reconstruction

Zero-shot MRI reconstruction relies on generative priors, but single-modality unconditional priors produce hallucinations under severe ill-posedness. In many clinical workflows, complementary MRI acquisitions (e.g. high-quality structural scans) are routinely available, yet existing reconstruction methods lack mechanisms to leverage this additional information. We propose MPFlow, a zero-shot multi-modal reconstruction framework built on rectified flow that incorporates auxiliary MRI modalities at inference time without retraining the generative prior to improve anatomical fidelity. Cross-modal guidance is enabled by our proposed self-supervised pretraining strategy, Patch-level Multi-modal MR Image Pretraining (PAMRI), which learns shared representations across modalities. Sampling is jointly guided by data consistency and cross-modal feature alignment using pre-trained PAMRI, systematically suppressing intrinsic and extrinsic hallucinations. Extensive experiments on HCP and BraTS show that MPFlow matches diffusion baselines on image quality using only 20% of sampling steps while reducing tumor hallucinations by more than 15% (segmentation dice score). This demonstrates that cross-modal guidance enables more reliable and efficient zero-shot MRI reconstruction.
Mar 2, 2026

Revisiting Global Token Mixing in Task-Dependent MRI Restoration: Insights from Minimal Gated CNN Baselines

Global token mixing, implemented via self-attention or state-space sequence models, has become a popular model design choice for MRI restoration. However, MRI restoration tasks differ substantially in how their degradations vary over image and k-space domains, and in the degree to which global coupling is already imposed by physics-driven data consistency terms. In this work, we ask the question whether global token mixing is actually beneficial in each individual task across three representative settings: accelerated MRI reconstruction with explicit data consistency, MRI super-resolution with k-space center cropping, and denoising of clinical carotid MRI data with spatially heteroscedastic noise. To reduce confounding factors, we establish a controlled testbed comparing a minimal local gated CNN and its large-field variant, benchmarking them directly against state-of-the-art global models under aligned training and evaluation protocols. For accelerated MRI reconstruction, the minimal unrolled gated-CNN baseline is already highly competitive compared to recent token-mixing approaches in public reconstruction benchmarks, suggesting limited additional benefits when the forward model and data-consistency steps provide strong global constraints. For super-resolution, where low-frequency k-space data are largely preserved by the controlled low-pass degradation, local gated models remain competitive, and a lightweight large-field variant yields only modest improvements. In contrast, for denoising with pronounced spatially heteroscedastic noise, token-mixing models achieve the strongest overall performance, consistent with the need to estimate spatially varying reliability. In conclusion, our results demonstrate that the utility of global token mixing in MRI restoration is task-dependent, and it should be tailored to the underlying imaging physics and degradation structure.
Feb 28, 2026

Direct low-field MRI super-resolution using undersampled k-space

Low-field magnetic resonance imaging (MRI) provides affordable access to diagnostic imaging but suffers from prolonged acquisition and limited image quality. Accelerated imaging can be achieved with k-space undersampling, while super-resolution (SR) and image quality transfer (IQT) methods typically rely on spatial-domain post-processing. In this work, we propose a novel framework for reconstructing high-field MR like images directly from undersampled low-field k-space. Our approach employs a k-space dual channel U-Net that processes the real and imaginary components of undersampled k-space to restore missing frequency content. Experiments on low-field brain MRI demonstrate that our k-space-driven image enhancement consistently outperforms the counterpart spatial-domain method. Furthermore, reconstructions from undersampled k-space achieve image quality comparable to full k-space acquisitions. To the best of our knowledge, this is the first work that investigates low-field MRI SR/IQT directly from undersampled k-space.
Feb 25, 2026

Learning spatially adaptive sparsity level maps for arbitrary convolutional dictionaries

State-of-the-art learned reconstruction methods often rely on black-box modules that, despite their strong performance, raise questions about their interpretability and robustness. Here, we build on a recently proposed image reconstruction method, which is based on embedding data-driven information into a model-based convolutional dictionary regularization via neural network-inferred spatially adaptive sparsity level maps. By means of improved network design and dedicated training strategies, we extend the method to achieve filter-permutation invariance as well as the possibility to change the convolutional dictionary at inference time. We apply our method to low-field MRI and compare it to several other recent deep learning-based methods, also on in vivo data, where the benefit of using a different dictionary is demonstrated. We further assess the method's robustness when tested on in- and out-of-distribution data. When tested on the latter, the proposed method suffers less from the data distribution shift compared to the other learned methods, which we attribute to its reduced reliance on training data due to its underlying model-based reconstruction component.
Feb 20, 2026

CogGen: Cognitive-Load-Inspired Fully Unsupervised Deep Generative Modeling for Compressively Sampled MRI Reconstruction

Fully unsupervised deep generative modeling (FU-DGM) offers significant potential for compressively sampled magnetic resonance imaging (CS-MRI) reconstruction. Representative FU-DGM formulations, such as deep image prior (DIP) and implicit neural representation (INR), employ architectural bias to induce a low-dimensional manifold in the image space that aligns with the forward observation. However, as the underlying inverse system is highly ill-posed, prolonged iterative fitting in FU-DGM typically leads to poor efficiency and noise amplification. In this paper, guided by the cognitive principle of easy-to-hard learning, we propose CogGen, an FU-DGM framework that reformulates CS-MRI reconstruction as a staged inversion problem. Specifically, CogGen implements an self-paced curriculum learning (SPCL)-driven progressive scheduling strategy through an MRI-aware dual-threshold weighting criterion, which adaptively regulates k-space measurement participation. The data-consistency residual thresholding evaluates the fitting reliability of the current generator, while the k-space radius thresholding controls stage-wise measurement exposure, thereby avoiding uniform fitting throughout optimization. Theoretically, our analysis shows that, when early stages favor easy-to-fit measurements, CogGen yields a reduced local sufficient-iteration bound and a smaller cumulative noise-amplification bound, explaining the improved convergence behavior and reconstruction fidelity of CogGen within a finite iteration budget. Numerical experiments demonstrate that both CogGen instantiations, CogGen-DIP and CogGen-INR, achieve superior performance over prevailing CS-MRI reconstruction techniques, including unsupervised and supervised pipelines.
Jan 30, 2026

MASC: Metal-Aware Sampling and Correction via Reinforcement Learning for Accelerated MRI

Metal implants in MRI cause severe artifacts that degrade image quality and hinder clinical diagnosis. Traditional approaches address metal artifact reduction (MAR) and accelerated MRI acquisition as separate problems. We propose MASC, a unified reinforcement learning framework that jointly optimizes metal-aware k-space sampling and artifact correction for accelerated MRI. To enable supervised training, we construct a paired MRI dataset using physics-based simulation, generating k-space data and reconstructions for phantoms with and without metal implants. This paired dataset provides simulated 3D MRI scans with and without metal implants, where each metal-corrupted sample has an exactly matched clean reference, enabling direct supervision for both artifact reduction and acquisition policy learning. We formulate active MRI acquisition as a sequential decision-making problem, where an artifact-aware Proximal Policy Optimization (PPO) agent learns to select k-space phase-encoding lines under a limited acquisition budget. The agent operates on undersampled reconstructions processed through a U-Net-based MAR network, learning patterns that maximize reconstruction quality. We further propose an end-to-end training scheme where the acquisition policy learns to select k-space lines that best support artifact removal while the MAR network simultaneously adapts to the resulting undersampling patterns. Experiments demonstrate that MASC's learned policies outperform conventional sampling strategies, and end-to-end training improves performance compared to using a frozen pre-trained MAR network, validating the benefit of joint optimization. Cross-dataset experiments on FastMRI with physics-based artifact simulation further confirm generalization to realistic clinical MRI data. The code and models of MASC have been made publicly available: https://github.com/hrlblab/masc
Jan 19, 2026

Pixelwise Uncertainty Quantification of Accelerated MRI Reconstruction

Parallel imaging techniques reduce magnetic resonance imaging (MRI) scan time but image quality degrades as the acceleration factor increases. In clinical practice, conservative acceleration factors are chosen because no mechanism exists to automatically assess the diagnostic quality of undersampled reconstructions. This work introduces a general framework for pixel-wise uncertainty quantification in parallel MRI reconstructions, enabling automatic identification of unreliable regions without access to any ground-truth reference image. Our method integrates conformal quantile regression with image reconstruction methods to estimate statistically rigorous pixel-wise uncertainty intervals. We trained and evaluated our model on Cartesian undersampled brain and knee data obtained from the fastMRI dataset using acceleration factors ranging from 2 to 10. An end-to-end Variational Network was used for image reconstruction. Quantitative experiments demonstrate strong agreement between predicted uncertainty maps and true reconstruction error. Using our method, the corresponding Pearson correlation coefficient was higher than 90% at acceleration levels at and above four-fold; whereas it dropped to less than 70% when the uncertainty was computed using a simpler a heuristic notion (magnitude of the residual). Qualitative examples further show the uncertainty maps based on quantile regression capture the magnitude and spatial distribution of reconstruction errors across acceleration factors, with regions of elevated uncertainty aligning with pathologies and artifacts. The proposed framework enables evaluation of reconstruction quality without access to fully-sampled ground-truth reference images. It represents a step toward adaptive MRI acquisition protocols that may be able to dynamically balance scan time and diagnostic reliability.
Jan 17, 2026

Accelerated MR Elastography Using Learned Neural Network Representation

To develop a deep-learning method for achieving fast high-resolution MR elastography from highly undersampled data without the need of high-quality training dataset. We first framed the deep neural network representation as a nonlinear extension of the linear subspace model, then used it to represent and reconstruct MRE image repetitions from undersampled k-space data. The network weights were learned using a multi-level k-space consistent loss. To further enhance reconstruction quality, phase-contrast specific magnitude and phase priors were incorporated, including the similarity of anatomical structures and smoothness of wave-induced harmonic displacement. Experiments were conducted using both 3D gradient-echo spiral and multi-slice spin-echo spiral MRE datasets. Compared to the conventional linear subspace-based approaches, the nonlinear network representation method was able to produce superior image reconstruction with suppressed noise and artifacts from a single in-plane spiral arm per MRE repetition (e.g., 2mm isotropic resolution in 1 min with a total R=10), yielding comparable stiffness estimation to the fully sampled data. This work demonstrated the feasibility of using deep network representations to model and reconstruct MRE images from highly-undersampled data, a nonlinear extension of the subspace-based approaches.