Prostate Cancer Detection
Latest papers
19 papers4 papers in the last four weeks, against 1 the four weeks before. 0.0% of all new papers.
The objective of this study is to investigate the role of clinical variables - their breadth, source, and quality - in the development, utility, and generalisability of an AI system for bi-parametric MRI (bpMRI)-based diagnosis of clinically significant prostate cancer (csPCa). Clinical context is added to the published PI-CAI-2B image-only model, whose weights are fixed. The study cohort comprises 6,022 biparametric MRI cases from 4,540 patients at University College London Hospitals NHS Foundation Trust (2019-2024), of which 4,834 cases (3,632 patients) are held out for internal testing. Forty-three clinical variables are drawn from structured health records, clinical letters, MRI reports, and automated image measurements. The primary endpoint is the difference in the area under the receiver operating characteristic curve (AUROC) between the image-context and image-only models on the internal test set. Secondary analyses compare combining strategies, the contribution of individual variables, and performance across subgroups. All models are further tested on five external cohorts from primary diagnosis and population-based screening.
ProtoCouncil: Multi-Encoder Anatomical Prototypes for Prostate Cancer Detection in Micro-Ultrasound
Purpose: Micro-ultrasound (US) is a promising modality for prostate cancer (PCa) detection, but identifying suspicious tissue depends heavily on clinical experience. Models trained on sparse, noisy core-level pathology offer little insight into their decisions and can fail under domain shift. Clinical use needs a traceable decision process and a flag for uncertain predictions. Methods: We introduce ProtoCouncil, in which three foundation encoders (MedSAM, DINOv3 and V-JEPA 2.1) learn case-based prototypes at three anatomical levels: whole gland, needle track and gland sectors. Prototypes are projected onto real training-core regions, and label-free fusion keeps every class logit as a bias plus an exact sum of prototype similarity contributions. Encoder disagreement triggers selective prediction. Results: In five-fold patient-level cross-validation (6,588 cores, 693 patients), ProtoCouncil reaches 82.9% AUROC for clinically significant PCa (csPCa, Grade Group 3), 4.3 points above the best previously published method. In zero-shot evaluation on two external cohorts, ProtoCouncil achieves higher all-cancer and csPCa AUROC than all previous methods. Nearest same-class exemplars match test-core tumor involvement better than random same-class cases. Externally, csPCa accuracy falls from 79% when encoders agree to 27% when two oppose the fused call. Abstaining on disagreement raises balanced accuracy by 7 and 15 points, while retaining 58% and 54% of the cores. Conclusion: ProtoCouncil grounds core-level predictions in exact similarity-based evidence from real, anatomically indexed training cases, which makes its reasoning interpretable. It achieves the highest csPCa AUROC across three cohorts and identifies unreliable predictions through encoder disagreement.
Improving PI-RADS Prediction and Prostate Cancer Detection from Multiparametric MRI with Anatomical Guidance
Accurate prediction of Prostate Imaging Reporting and Data System (PI-RADS) scores from multiparametric MRI (mpMRI) remains challenging, more so than clinically significant prostate cancer (csPCa) detection. Given the importance of lesion location in PI-RADS scoring, we evaluated whether incorporating prostate zonal masks improves PI-RADS prediction and csPCa detection across multiple architectures (3D ResNet-18, ResNet-50, and ViT) using a large-scale internal dataset. Anatomical guidance generally improved performance across architectures, with the best results achieved by ResNet-18 with 2-zone guidance for PI-RADS prediction (QWK = 0.511) and ResNet-50 with 5-zone guidance for csPCa detection (AUC = 0.809). Fine-tuned results on external datasets further demonstrated the benefits of anatomical guidance. Furthermore, models with anatomical guidance improved the utility of model-predicted PI-RADS scores for PI-RADS-based csPCa detection (positive defined as PI-RADS>=3). Combining model-predicted and expert-assigned PI-RADS scores significantly increased the AUC from 0.711 to 0.756 (p < 0.05), suggesting that AI-derived PI-RADS scores may provide complementary information to expert assessment for csPCa detection. Overall, our findings highlight the value of incorporating prostate zonal anatomy into deep learning-based prostate MRI assessment.
Conditional Diffusion-Based Generation of T2-Weighted Prostate MRI for Clinically Significant Prostate Cancer Classification
Scarce and unrepresentative training data limit the performance of prostate MRI prediction models. Synthetic T2-weighted (T2W) MRI may augment training data containing clinically significant prostate cancer (csPCa) and transition zone (TZ) lesions. In this retrospective, single-center, ethics-committee-approved study, we developed a conditional generative model for T2W prostate MRI extending MAISI-v2 with csPCa class, zonal, and lesion-mask-guided conditioning, incorporating a relative advantage weighted loss fine-tuned on 1,303 patients (1,654 lesions). Fidelity was assessed by incremental ablation, and downstream utility was evaluated with T2W-based csPCa classifiers across five simulated training-data scenarios, each testing 18 synthetic-data configurations. The proposed model reduced Fréchet inception distance (FID) from 13.28 (pretrained MAISI-v2) to internally (PI-CAI: ). Synthetic augmentation significantly increased AUC in all five scenarios (+0.027 to +0.088; adjusted --), though cross-institutional augmentation of PI-CAI yielded a non-significant gain (+0.013; ). Overall, our model improved T2W MRI fidelity, and synthetic images improved csPCa classification under simulated data constraints, although benefit did not transfer significantly across institutions.
End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI
Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). We performed ablations with end-to-end training and data consistency (DC) enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04-0.11). With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.
Weakly Supervised Spatial Grounding for Discriminative Attention-Based Ultrasound-Histopathology Alignment in Prostate Cancer Grading
Unpaired cross-modal distillation transfers grade structure from histopathology into a micro-ultrasound (micro-US) encoder by aligning a pooled needle-region embedding to a frozen histopathology teacher under grade-group correspondence alone. A single objective is thereby required to serve two distinct functions: rendering patch features discriminative of tissue state, and selecting which patches enter the pooled representation. We decouple them. Weak spatial supervision derived from percentage involvement, recorded routinely at biopsy, constrains the predicted proportion of malignant tissue within each core, acting on the encoder features independently of the alignment objective. The alignment loss then operates on features that differ across a core, and attention concentrates on a subset of patches rather than remaining near-uniform. On 7,166 biopsy cores from 811 patients across seven centers under patient-level 5-fold cross-validation, the method reaches 67.1 macro AUC and 68.5 csPCa AUC, against 61.2 and 52.8 for the existing unpaired alignment method and 63.1 and 62.6 for the strongest unimodal baselines. Ablation against existing attention regularizers designed to prevent attention-uniformity collapse shows that such regularizers do not substitute for label-derived supervision: they constrain the attention distribution, whereas the signal required acts on the features that attention reads.
An end-to-end-trained vision-language model for native-language prostate pathology report generation
Prostate cancer is among the most frequently diagnosed malignancies worldwide, and structured reporting of each biopsy core burdens pathologists. Existing tools frame this as classification, leaving pathologists to assemble coherent reports, while many slide-level vision-language models rely on English-centric encoders that transfer poorly to other clinical languages. We present a slide-level framework generating prostate biopsy reports that is language-independent by construction: tokenizer and model are trained from scratch, demonstrated here in German. To address paired-data scarcity, an automated pipeline uses a locally deployed large language model to split composite reports into core-specific image-text pairs, yielding 17,344 pairs from 2,402 historical cases without manual annotation. Evaluated for clinical attributes rather than linguistic similarity, the model achieves 96.2% F1 for malignancy detection and 65.2% for Gleason grading, competitive with an FDA-cleared classifier. Grading is further validated on three external cohorts with latent-space augmentation. Institutions can thus train native-language reporting models on their own archives.
Learning Prostate Anatomy at Test Time for Cancer Detection in Micro-Ultrasound
Domain shift across clinical centers using different imaging hardware or acquisition protocols remains a fundamental barrier to deploying deep learning models for prostate cancer (PCa) detection. Existing test-time adaptation (TTA) methods address distribution shift through entropy minimization or augmentation-based self-supervision, correcting for statistical differences in image appearance but ignoring the anatomical structure of the target domain. We propose ANT, a segmentation-guided TTA framework that adapts a pretrained cancer detection encoder to the target domain by solving an auxiliary prostate segmentation task at test time, supervised by pseudo-masks from a frozen pretrained segmentation network. By aligning encoder representations to prostate anatomy in the target domain, ANT corrects domain-specific feature drift while preserving cancer-discriminative structure. The model was trained on 693 patients imaged with an earlier-generation micro-ultrasound scanner in a multi-center clinical trial, and evaluated on 118 patients acquired with a newer-generation system across two centers in another clinical trial. Under a leave-one-center-out protocol with identical evaluation conditions across all methods, ANT improves mean AUC by 2.9% and 3.6% at the biopsy-core and patient levels, respectively, over no adaptation, outperforming TTA baselines. Code is available at: https://github.com/ObedDzik/ant.git.
Zero-Shot Adaptation of Medical Vision Foundation Models for High-Frequency Micro-Ultrasound Prostate Segmentation
Prostate cancer claims a life every 80 seconds. Early detection is needed to prevent disease progression, and both PSA density calculation and biopsy decisions rely on knowing the exact boundary of the gland. Conventional ultrasound at 6-12 MHz blurs this boundary, missing one in three high-risk cancers. Micro-ultrasound (29 MHz) improves resolution threefold but introduces dense acoustic speckle that obscures the outer wall; given the same image, two clinicians draw outlines differing by over 10% in area. Supervised methods are costly and generalise poorly across scanners. Can a foundation model segment the prostate with no training data? We present the first zero-shot pipeline for this modality: MedSAM, pre-trained on over 1.5 million medical images, localises the prostate; we then apply CLAHE to sharpen the outer wall, binary dilation to recover missed pixels, and Fourier smoothing (4 modes, s=1.05) to refine the boundary. MedSAM requires a spatial prompt, so we evaluate bounding-box and point-click strategies across 75 patients of the Micro-Ultrasound Prostate Segmentation dataset (2,621 slices). On the 20-patient held-out test set, the pipeline reduces mean boundary-distance error by 45% (Dice 0.749+/-0.043 to 0.865+/-0.029; HD95 217.2+/-36.9 to 120.1+/-26.1 px), reaching Dice 0.859 across the cohort. Its mean overlap shows no significant difference from the three non-expert rater groups (p>0.19), while segmenting 38-52% more consistently (lower inter-patient standard deviation). Point-click prompts fail regardless of placement (best Dice=0.350), because speckle gives no stable local contrast. Only an approximate bounding box is required, so any clinic can deploy it without data collection, annotation, or retraining.
Histopathological Spectrum-Guided Prostate Stratification via Segmentation-Assisted Diagnostic Transformer
Prostate cancer diagnosis with multiparametric MRI (mpMRI) is commonly based on PI-RADS assessment or binary classification, which suffer from subjectivity and fail to capture clinically relevant pathological heterogeneity. To address this limitation, we construct a Prostate Cancer Histopathology Spectrum Dataset (PCa-HSD) and formulate a clinically meaningful four-class classification task, addressing the underrepresentation of benign lesions that are easily confounded with prostate cancer in existing datasets. We propose Language-guided Segmentation-assisted Diagnostic Transformer model (LSDT), which leverages zero-shot segmentation to provide anatomical priors and performs effective multi-modal slice fusion for classification. Our proposed method consistently improves accuracy across backbones, achieving the best average accuracy of 0.633 and JointRecall of 0.768 in five-fold cross-validation on a cohort of 344 patients. These results demonstrate that integrating pathology supervision and anatomical priors significantly enhances fine-grained prostate MRI classification and provides a more clinically relevant paradigm for risk stratification. Code will be made publicly available in a future revision.
Compass: Prostate Cancer Detection Needs Multi-View Context
Artificial intelligence (AI) analysis of micro-ultrasound (US) has shown promise for prostate cancer (PCa) detection. However, most existing AI methods focus on the analysis of single US images in isolation. By contrast, expert US readers typically assess a full recorded video study, which provides three-dimensional context, to improve PCa detection compared to single-frame analysis. Inspired by this clinical workflow, we propose Compass, a novel AI methodology which models a US study as a stream of 2D images. Compass jointly integrates rotational sweep videos of the prostate with US frames acquired at the moment of biopsy, and performs evidence aggregation across the study using a transformer conditioned on the probe's rotational angle. Finally, a decoder head predicts frame-level and study-level risk scores for the patient. The model is trained and evaluated using a multi-center clinical trial dataset of US studies, including continuous rotational scans of the prostate and videos captured during biopsy acquisition. We compare the proposed method to baseline AI methods from the literature and to risk scores provided by clinical experts. Our framework shows strong performance, highlighting the value of multi-view context for US PCa detection, and providing a potentially powerful tool to complement human expertise in US-based PCa diagnosis. Our code is available at: https://github.com/mharmanani/Compass.
Learning Where to Look: A Reinforcement Learning Framework for Robust Micro-Ultrasound Prostate Cancer Detection
Micro-ultrasound (US) is a new, emerging, and promising imaging modality for prostate cancer (PCa) detection, but accurate identification of suspicious tissue remains highly dependent on clinical experience, leading to substantial inter-observer variability. Machine-learning assistance can reduce this variability; however, training reliable deep models is challenging because supervision is sparse and noisy -- typically limited to core-level histopathology outcomes (e.g., cancer grade and its percentage in a biopsy core) without pixel-level lesion annotations and under severe class imbalance. We introduce Prost-RL, which reframes US PCa detection as a spatially aware, policy-driven inference problem by learning where to look before decoding. Prost-RL integrates a lightweight reinforcement-learning policy into a foundation-model encoder-decoder to generate interpretable spatial attention maps that act as soft prompts for both cancer-likelihood heatmap prediction and image-level classification. We further propose Adaptive Policy Optimization (APO) to stabilize hybrid supervised-RL training and a noise-robust objective combining symmetric cross-entropy with negative-entropy regularization to mitigate weak-label noise and encourage sharp localization. On a cohort of 6,607 biopsy cores from 693 patients across five clinical sites, Prost-RL achieves AUROC with % sensitivity at 80% specificity for core-level detection (+2.1 AUROC and +4.5 sensitivity points over the strongest baseline), and AUROC for clinically significant cancer classification. The learned policy highlights biopsy-aligned regions, providing transparent, spatially grounded evidence alongside quantitative risk predictions. Code is available at: https://github.com/DeepRCL/Prost-RL.
A multi-architecture study of specificity refinement and false-positive mechanism analysis in prostate MRI
Objectives: To characterize residual false positives in prostate MRI detection, and to evaluate a lightweight post-hoc refinement head for case-level specificity. Materials and Methods: This retrospective study used PI-CAI (5-fold cross-validation) and Prostate158 (n=158; external). A context-aware evidence head and an 89,216-parameter refinement head were trained on a frozen detection backbone; the evidence head was also trained on four further backbones (bare nnU-Net, bare U-Net, bare Mamba, MIGF-Mamba). For each false-positive region, T2-weighted, apparent-diffusion-coefficient, and high-b-value contrast ratios versus peri-lesional rings were compared against ground-truth lesions and contralateral benign regions. Results: False positives were closer to true cancers than to benign tissue in evidence and raw T2-weighted and apparent-diffusion-coefficient contrast, reproducing 35/35 across five architectures (Cohen's d 1.10; FP/benign evidence ratio 2.38x) and 105/105 across modality-perturbation scenarios. On PI-CAI fold-0, refinement raised case-level specificity from 0.469 to 0.549 (+17.2%) at preserved sensitivity (0.943); 5-fold cross-validation showed fold-conditional behavior (9/15 observations positive; range -22% to +28%). On Prostate158, both models saturated (McNemar pooled p=0.69), while the false-positive contrast-matching finding replicated. Conclusion: Residual false positives are contrast-matched to cancer (sharing raw imaging features rather than histologically confirmed mimicry), reproducing across five architectures -- a data-level imaging property, not model-specific artifacts; post-hoc refinement adds practical specificity in-domain but is fold-conditional.
HFS-TriNet: A Three-Branch Collaborative Feature Learning Network for Prostate Cancer Classification from TRUS Videos
Transrectal ultrasound (TRUS) imaging is a cost-effective and non-invasive modality widely used in the diagnosis of prostate cancer. The computer-aided diagnosis (CAD) relying on TRUS images has been extensively investigated recently. Compared to static images, TRUS video provides richer spatial-temporal information, which make it a promising alternative for improving the accuracy and robustness of CAD systems. However, TRUS video analysis also introduces new challenges. These include information redundancy, which increases computational costs; high intra- and inter-class similarity, which complicates feature extraction; and a low signal-to-noise ratio, which hinders the identification of clinically relevant information. To address these problems, we propose a heuristic frame selection (HFS) and a three-branch collaborative feature learning network (HFS-TriNet) for prostate cancer classification from TRUS videos. Specifically, selecting a clip of video frames at intervals for training can mitigate redundancy. The HFS strategy dynamically initializes the starting point of each training clip, which ensures that the sampled clips span the entire video sequence. For better feature extraction, besides a regular ResNet50 branch, we also utilize 1) a large model branch based a pre-trained medical segment anything model (SAM) to extract deep features of each frame and a normalization-based attention module to explore the temporal consistency; and 2) a wavelet transform convolutional residual (WTCR) branch that extracts lesion edge information in the high-frequency domain and performs denoising in the low-frequency domain.
Hybrid Multi-Dimensional MRI Prostate Cancer Detection via Hadamard Network-Based Bias Correction and Residual Networks
Magnetic Resonance Imaging (MRI) is vital for prostate cancer (PCa) diagnosis. While advanced techniques such as Hybrid Multi-dimensional MRI (HM-MRI) have enhanced diagnostic capabilities, the significant need remains for robust, automated Artificial Intelligence (AI)-based detection methods. In this study, we combine quantitative HM-MRI of tissue composition with an AI-based neural network. We propose the Hadamard-Bias Network plus ResNet18 (HBR-Net-18), a two-stage AI framework for PCa detection. In the first stage, a Hadamard U-Net-based algorithm suppresses intensity inhomogeneities (bias fields) across six parametric HM-MRI maps generated via a Physics-Informed Autoencoder (PIA). In the second stage, a Residual Network (ResNet-18) performs patch-level classification. The framework utilizes overlapping 11-by-11 patches, incorporating both 2D intra-slice and 3D inter-slice (adjacent-slice) information to improve spatial consistency. Our experimental results demonstrate that HB-Net achieves balanced sensitivity and specificity, significantly outperforming conventional radiomics-based approaches and baseline CNN models, highlighting its potential for clinical deployment.
Maximizing T2-Only Prostate Cancer Localization from Expected Diffusion Weighted Imaging
Multiparametric MRI is increasingly recommended as a first-line noninvasive approach to detect and localize prostate cancer, requiring at minimum diffusion-weighted (DWI) and T2-weighted (T2w) MR sequences. Early machine learning attempts using only T2w images have shown promising diagnostic performance in segmenting radiologist-annotated lesions. Such uni-modal T2-only approaches deliver substantial clinical benefits by reducing costs and expertise required to acquire other sequences. This work investigates an arguably more challenging application using only T2w at inference, but to localize individual cancers based on independent histopathology labels. We formulate DWI images as a latent modality (readily available during training) to classify cancer presence at local Barzell zones, given only T2w images as input. In the resulting expectation-maximization algorithm, a latent modality generator (implemented using a flow matching-based generative model) approximates the latent DWI image posterior distribution in the E-steps, while in M-steps a cancer localizer is simultaneously optimized with the generative model to maximize the expected likelihood of cancer presence. The proposed approach provides a novel theoretical framework for learning from a privileged DWI modality, yielding superior cancer localization performance compared to approaches that lack training DWI images or existing frameworks for privileged learning and incomplete modalities. The proposed T2-only methods perform competitively or better than baseline methods using multiple input sequences (e.g., improving the patient-level F1 score by 14.4% and zone-level QWK by 5.3% over the T2w+DWI baseline). We present quantitative evaluations using internal and external datasets from 4,133 prostate cancer patients with histopathology-verified labels.
Interpretable Prostate Cancer Detection using a Small Cohort of MRI Images
Prostate cancer is a leading cause of mortality in men, yet interpretation of T2-weighted prostate MRI remains challenging due to subtle and heterogeneous lesions. We developed an interpretable framework for automatic cancer detection using a small dataset of 162 T2-weighted images (102 cancer, 60 normal), addressing data scarcity through transfer learning and augmentation. We performed a comprehensive comparison of Vision Transformers (ViT, Swin), CNNs (ResNet18), and classical methods (Logistic Regression, SVM, HOG+SVM). Transfer-learned ResNet18 achieved the best performance (90.9% accuracy, 95.2% sensitivity, AUC 0.905) with only 11M parameters, while Vision Transformers showed lower performance despite substantially higher complexity. Notably, HOG+SVM achieved comparable accuracy (AUC 0.917), highlighting the effectiveness of handcrafted features in small datasets. Unlike state-of-the-art approaches relying on biparametric MRI (T2+DWI) and large cohorts, our method achieves competitive performance using only T2-weighted images, reducing acquisition complexity and computational cost. In a reader study of 22 cases, five radiologists achieved a mean sensitivity of 67.5% (Fleiss Kappa = 0.524), compared to 95.2% for the AI model, suggesting potential for AI-assisted screening to reduce missed cancers and improve consistency. Code and data are publicly available.
ProFound: A moderate-sized vision foundation model for multi-task prostate imaging
Many diagnostic and therapeutic clinical tasks for prostate cancer increasingly rely on multi-parametric MRI. Automating these tasks is challenging because they necessitate expert interpretations, which are difficult to scale to capitalise on modern deep learning. Although modern automated systems achieve expert-level performance in isolated tasks, their general clinical utility remains limited by the requirement of large task-specific labelled datasets. In this paper, we present ProFound, a domain-specialised vision foundation model for volumetric prostate mpMRI. ProFound is pre-trained using several variants of self-supervised approaches on a diverse, multi-institutional collection of 5,000 patients, with a total of over 22,000 unique 3D MRI volumes (over 1,800,000 2D image slices). We conducted a systematic evaluation of ProFound across a broad spectrum of downstream clinical tasks on over 3,000 independent patients, including prostate cancer detection, Gleason grading, lesion localisation, gland volume estimation, zonal and surrounding structure segmentation. Experimental results demonstrate that finetuned ProFound consistently outperforms or remains competitive with state-of-the-art specialised models and existing medical vision foundation models trained/finetuned on the same data.
GUIDE-US: Grade-Informed Unpaired Distillation of Encoder Knowledge from Histopathology to Micro-UltraSound
Purpose: Non-invasive grading of prostate cancer (PCa) from micro-ultrasound (micro-US) could expedite triage and guide biopsies toward the most aggressive regions, yet current models struggle to infer tissue micro-structure at coarse imaging resolutions. Methods: We introduce an unpaired histopathology knowledge-distillation strategy that trains a micro-US encoder to emulate the embedding distribution of a pretrained histopathology foundation model, conditioned on International Society of Urological Pathology (ISUP) grades. Training requires no patient-level pairing or image registration, and histopathology inputs are not used at inference. Results: Compared to the current state of the art, our approach increases sensitivity to clinically significant PCa (csPCa) at 60% specificity by 3.5% and improves overall sensitivity at 60% specificity by 1.2%. Conclusion: By enabling earlier and more dependable cancer risk stratification solely from imaging, our method advances clinical feasibility. Source code will be publicly released upon publication.