cs.AINov 20, 2026

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

Authors: Yiwen Qiu, Che Sun, Shu Shen, Wentao Wang

Organizations: Department of Liver Surgery, West China Hospital of Sichuan University, Chengdu, China · Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China

Abstract

On-premise clinical AI agents must auto-accept high-confidence diagnoses, deferring others to clinician review, yet token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute. We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol. Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels. Calibration freezes a nominal top-50% threshold, selecting single-run, five-run consistency, or full-deferral tiers by whether the one-sided 95% Wilson lower confidence bound of pass rate among accepted cases meets the 95% clinical target line. Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases, MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute; CDM achieved 96.00% test attainment by escalating to the five-run consistency tier; cross-specialty, missing-imaging, and combined enriched cohorts entered the full-deferral tier, capping calibration false-certification rate at 0.00%-3.50%.

Explore similar work

Nov 20, 2026

Scalable Evaluation of Medical AI using Evidence-based Practice Recommendations

Rigorously evaluating medical artificial intelligence (AI) requires testing open-ended clinical management across diverse presentations and stages of care. However, existing benchmarks rely on manual expert authoring, limiting coverage across conditions, conditional care pathways, and evolving guidelines. We develop an automated pipeline that extracts and verifies structured clinical criteria and branching decision trees from practice recommendations to generate scenarios spanning the care continuum, including nuanced presentations and practice variations across regions and guideline editions. Applied to 436 BMJ Best Practice clinical monographs (354 US, 82 International), this yields 3,200 scenarios spanning differential diagnosis, investigations, treatment, and complications, plus targeted suites for regional specificity (731 US/International pairs) and temporal freshness (630 scenarios). To grade responses, we develop a clinician-calibrated autorater that scores management plans on a 4-point rubric stratifying deviations by clinical severity. Across Gemini models, scaling improves adherence, while web search (+0.8 percentage points [pp] on average) and multi-sample synthesis (+2.2 pp) combine additively (+2.8 pp). In context, full monographs consistently trail condensed excerpts. On targeted suites, web search narrows international performance gaps (+4.2 pp) and improves adherence to newly updated guidance (+4.6 pp). In a study with Primary Care Physicians (n = 9) across 200 scenarios, AI assistance raises adherence from 50.5% to 70.0%, driven largely by fewer clinical omissions. Overall, our results demonstrate a scalable evaluation setup using an evidence-based corpus originally written to guide human clinical decision-making, and demonstrate its viability to assess medical AI and its assistance on clinician decision-making.
Mar 25, 2026

Multi-Agent Reasoning with Consistency Verification Improves Uncertainty Calibration in Medical MCQA

Miscalibrated confidence scores are a practical obstacle to deploying AI in clinical settings. A model that is always overconfident offers no useful signal for deferral. We present a multi-agent framework that combines domain-specific specialist agents with Two-Phase Verification (Wu et al., 2024) and S-Score Weighted Fusion to improve both calibration and discrimination in medical multiple-choice question answering. Four specialist agents (respiratory, cardiology, neurology, gastroenterology) generate independent diagnoses using Qwen2.5-7B-Instruct. Each diagnosis undergoes a two-phase self-verification process that measures internal consistency and produces a Specialist Confidence Score (S-score). The S-scores drive a weighted fusion strategy that selects the final answer and calibrates the reported confidence. We evaluate on high-disagreement subsets of MedQA-USMLE and MedMCQA (100 and 250 questions). All results are specific to this filtered regime. On MedQA-250, the full system achieves ECE = 0.091 (74.4% reduction over the single-specialist baseline) and AUROC = 0.630 (+0.056) at 59.2% accuracy. Calibration gains of 49-74% hold across all four settings. Ablation analysis reveals that Two-Phase Verification drives ECE reduction while multi-agent reasoning drives AUROC improvement, suggesting that consistency checking and ensemble aggregation address different failure modes of LLM uncertainty. Whether the resulting confidence signal is sufficient to support clinical deferral decisions in practice remains a direction for future investigation.
Nov 20, 2026

Observed, Curated, Reused: Observation Bias in Clinical AI Evaluation

Clinical AI evaluations are vulnerable to observation bias embedded in routine medical documentation, which captures only what clinicians notice, test, and record rather than a complete clinical picture. As this evidence travels into publications and reference knowledge graphs, crucial distinctions disappear: unexamined symptoms blur with confirmed negatives, and chronological disease progression is lost. Surviving evidence can also enter both the benchmark query and the reference knowledge base, creating a self-referential loop where a patient is evaluated against clues derived from their own published case report. To quantify this bias, we tracked 6,503 clinical cases across six historical Human Phenotype Ontology (HPO) releases (October 2021-June 2026) to identify when HPO first cited the publications describing them. This yielded a confirmatory cohort with an observable "source ingestion" event, where HPO cited a case's source publication as target-disease evidence. Diagnostic rankers depended heavily on these source publications: for our primary semantic ranker (Resnik), publication-weighted mean reciprocal rank rose from 0.26 before paper ingestion to 0.84 upon inclusion in HPO, but collapsed to 0.05 when source-linked assertions were counterfactually removed. Two additional rankers (IC-cosine and LIRICAL) reproduced this trajectory, and control experiments confirmed the diagnostic jump was driven by the patient's publication rather than background HPO growth. Clinical AI systems may therefore score well because their knowledge base contains evidence linked to the test case's source publication, rather than through generalization. Modern knowledge is not the problem; evaluation evidence must match the claim. Trustworthy benchmarks must separate patients, source-linked evidence, and time: historical tests should use only knowledge available at the intended decision time.