Magnetic Resonance Imaging

Also known as MRI

Overview

Magnetic resonance imaging research studies how to acquire, reconstruct, interpret, and quantify images of the body, from structural brain scans to cardiac motion and tissue microstructure. Approaches include physics-based and compressed-sensing reconstruction, deep unrolled networks, diffusion models and implicit representations, alongside methods for segmentation, diagnosis, image synthesis, and scanner harmonization. Work increasingly combines these tools with acquisition physics, multimodal or longitudinal data, and uncertainty estimates to accelerate scans and support clinical measurements. A central challenge is ensuring that reconstructed or synthesized detail is genuinely supported by the measurements and that models remain reliable across scanners, field strengths, protocols, and patient populations.

Latest papers

275 papers28 papers in the last four weeks, up 27% on the four weeks before. 0.2% of all new papers.

Dec 4, 2025

Equivariant symmetry-aware head pose estimation for fetal MRI

We present E(3)-Pose, a novel fast pose estimation method that jointly and explicitly models rotation equivariance and object symmetry. Our work is motivated by the challenging problem of accounting for fetal head motion during a diagnostic MRI scan. We aim to enable automatic adaptive prescription of diagnostic 2D MRI slices with 6-DoF head pose estimation, supported by rapid low-resolution 3D MRI volumes acquired before each 2D slice. Existing pose estimation methods struggle to generalize to clinical volumes due to pose ambiguities induced by inherent anatomical symmetries, as well as low resolution, noise, and artifacts. In contrast, E(3)-Pose captures anatomical symmetries and rigid pose equivariance by construction, and yields robust estimates of the fetal head pose. Our experiments on publicly available and representative clinical fetal MRI datasets demonstrate the superior robustness and generalization of our method across domains. Crucially, E(3)-Pose achieves state-of-the-art accuracy on clinical MRI volumes, supporting future clinical translation. Our implementation is publicly available at github.com/MedicalVisionGroup/E3-Pose.
Sep 15, 2025

End-to-End 4D Heart Mesh Recovery Across Full-Stack and Sparse Cardiac MRI

Reconstructing cardiac motion from CMR sequences is critical for diagnosis, prognosis, and intervention. Existing methods rely on complete CMR stacks to infer full heart motion, limiting their applicability during intervention when only sparse observations are available. We present TetHeart, the first end-to-end framework for unified 4D heart mesh recovery from both offline full-stack and intra-procedural sparse-slice observations. Our method leverages deformable tetrahedra to capture shape and motion in a coherent space shared across cardiac structures. Before a procedure, it initializes detailed, patient-specific heart meshes from high-quality full stacks, which can then be updated using whatever slices can be obtained in real-time, down to a single one during the procedure. TetHeart incorporates several key innovations: (i) an attentive slice-adaptive 2D-3D feature assembly mechanism that integrates information from arbitrary numbers of slices at any position; (ii) a distillation strategy to ensure accurate reconstruction under extreme sparsity; and (iii) a weakly supervised motion learning scheme requiring annotations only at keyframes, such as the end-diastolic and end-systolic phases. Trained and validated on three large public datasets and evaluated zero-shot on additional private interventional and public datasets without retraining, TetHeart achieves state-of-the-art accuracy and strong generalization in both pre- and intra-procedural settings. Code and dataset is available at https://github.com/Scalsol/TetHeart.
Sep 11, 2025

Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner

Biophysical diffusion MRI models like Neurite Exchange Imaging (NEXI) are essential for probing gray matter microstructure, estimating compartment diffusivities, neurite fraction, and exchange time. However, NEXI's multi-shell, multi-diffusion-time requirements cause prohibitively long acquisitions. Leveraging the Connectome 2.0 ultra-high gradient scanner, we developed a time-efficient protocol using an Explainable AI (XAI) framework. Combining XGBoost, SHAP, and Recursive Feature Elimination trained on synthetic signals, XAI identified an optimal 8-feature subset, cutting scan time from 27 to 14 minutes. Validated in vivo in seven healthy participants, the XAI protocol was benchmarked against the full 15-feature acquisition, a Cram'er-Rao Lower Bound (CRLB) theoretical optimum, and two heuristics ("Mid-Range" and "Corner"). It robustly reproduced parameter estimates and maintained test-retest reproducibility. Remarkably, the XAI selection converged to the CRLB optimum. This validates XAI's optimality while highlighting its main advantage: achieving gold-standard optimization without complex analytical Jacobians, making it easily adaptable to numerical models or complex noise where CRLB is intractable. Furthermore, XAI showed superior in vivo robustness over heuristics: "Mid-Range" sampling yielded biased exchange time estimates from insufficient temporal diversity, while "Corner" sampling gave unstable intra-neurite diffusivity estimates (5-fold higher CV) due to noise sensitivity. Ultimately, this robust 14-minute protocol accelerates exchange-sensitive microstructural mapping, establishing a model-agnostic optimization framework adaptable to future ultra-high gradient systems and existing clinical scanners.
Jul 18, 2025

Converting T1-weighted MRI from 3T to 7T quality using deep learning

Ultra-high resolution 7 tesla (7T) magnetic resonance imaging (MRI) provides detailed anatomical views, offering better signal-to-noise ratio, resolution and tissue contrast than 3T MRI, though at the cost of accessibility. We present an advanced deep learning model for synthesizing 7T brain MRI from 3T brain MRI. Paired 7T and 3T T1-weighted images were acquired from 172 participants (124 cognitively unimpaired, 48 impaired) from the Swedish BioFINDER-2 study. To synthesize 7T MRI from 3T images, we trained two models: a specialized U-Net, and a U-Net integrated with a generative adversarial network (GAN U-Net). Our models outperformed two previous state-of-the-art 3T-to-7T models in image-based evaluation metrics. Four blinded MRI professionals judged our synthetic 7T images as comparable in detail to real 7T images, and superior in subjective visual quality to 7T images, due to the reduction of artifacts. Using both SynthSeg and NextBrain, automated segmentations of the synthetic 7T images were more similar to real 7T segmentations than automated segmentations from the 3T images that were used to synthesize the 7T images. Finally, synthetic 7T images showed similar performance to real 3T images in downstream prediction of cognitive status using MRI derivatives (n=3,168). In all, we show that synthetic T1-weighted brain images approaching 7T quality can be generated from 3T images, which may improve image quality and segmentation, without compromising performance in downstream tasks. Future directions, possible clinical use cases, and limitations are discussed.
Jul 10, 2025

ArteryX: A Reliable End-to-End Toolbox for Standardized Intracranial Artery Feature Extraction from 3D TOF-MRA

Cerebrovascular research heavily relies on quantitative analysis of intracranial arteries from time-of-flight magnetic resonance angiography, yet existing processing pipelines remain limited by inconsistent artery labeling and a high manual correction burden. We present ArteryX, a toolbox for extracting features that standardizes artery classification across proximal and distal vascular territories. It integrates segmentation handling, isotropic processing, vessel-fused graph construction, and constrained landmark-based classification within a unified artery-specific feature reporting and reproducible workflow. The toolbox extracts morphological, topological, and complexity features including total length, mean radius, volume, surface area, branch count, tortuosity, and fractal dimensionality for standardized artery-segments. Test-and-validation were performed using three complementary datasets: (1)TopBrain-Challenge benchmarking with annotated arteries, (2)synthetic known-reference validation, and (3)exploratory in-vivo cohort of cerebral small vessel disease. In TopBrain analyses, ArteryX with supervised nnUnet segmentation showed minimal bias, while iCafe showed the highest bias and a large limit-of-agreement. ArteryX consistently demonstrated robust downstream quantification performance across segmentation sources (unsupervised/supervised). Agreement analyses showed minimal bias for radius and good sensitivity of extent-dependent metrics throughout the noisier segmentations compared to the state-of-the-art iCafe-toolbox. Furthermore, a stage-wise human-in-the-loop protocol showed lower intervention time than iCafe. In an in-vivo-cohort (48CSVD+, 20CSVD-), ArteryX-derived distal and territory-level features showed group-level differences, not evident with iCafe. To facilitate adoption-and-reproducibility, ArteryX is designed with versioned builds, tutorials, and documentation.