Overview

3D medical imaging studies how to extract anatomical and clinical information from scans while preserving relationships across slices. CNNs, transformers, and self-supervised foundation models support tasks such as segmentation, lesion detection, registration, and report generation, evaluated on settings including BraTS brain MRI and LIDC-IDRI lung CT. For reconstruction and image enhancement, methods combine measured scan data and physical models with diffusion or flow models, neural fields, and Gaussian splatting. A central tension is that full-volume models capture spatial context but demand substantial computation, while slice-based approaches are cheaper; generalization across scanners and reliable clinical evaluation remain open challenges.

Latest papers

173 papers13 papers in the last four weeks, level with the four weeks before. 0.1% of all new papers.

Mar 9, 2026

VesselFusion: Diffusion Models for Vessel Centerline Extraction from 3D CT Images

Vessel centerline extraction from 3D CT images is an important task because it reduces annotation effort to build a model that estimates a vessel structure. It is challenging to estimate natural vessel structures since conventional approaches are deterministic models, which cannot capture a complex human structure. In this study, we propose VesselFusion, which is a diffusion model to extract the vessel centerline from 3D CT image. The proposed method uses a coarse-to-fine representation of the centerline and a voting-based aggregation for a natural and stable extraction. VesselFusion was evaluated on a publicly available CT image dataset and achieved higher extraction accuracy and a more natural result than conventional approaches.
Mar 8, 2026

Interpretable Aneurysm Classification via 3D Concept Bottleneck Models: Integrating Morphological and Hemodynamic Clinical Features

We are concerned with the challenge of reliably classifying and assessing intracranial aneurysms using deep learning without compromising clinical transparency. While traditional black-box models achieve high predictive accuracy, their lack of inherent interpretability remains a significant barrier to clinical adoption and regulatory approval. Explainability is paramount in medical modeling to ensure that AI-driven diagnoses align with established neurosurgical principles. Unlike traditional eXplainable AI (XAI) methods -- such as saliency maps, which often provide post-hoc, non-causal visual correlations -- Concept Bottleneck Models (CBMs) offer a robust alternative by constraining the model's internal logic to human-understandable clinical indices. In this article, we propose an end-to-end 3D Concept Bottleneck framework that maps high-dimensional neuroimaging features to a discrete set of morphological and hemodynamic concepts for aneurysm identification. We implemented this pipeline using a pre-trained 3D ResNet-34 backbone and a 3D DenseNet-121 to extract features from CTA volumes, which were subsequently processed through a soft bottleneck layer representing human-interpretable clinical concepts. The model was optimized using a joint-loss function to balance diagnostic focal loss and concept mean squared error (MSE), validated via stratified five-fold cross-validation. Our results demonstrate a peak task classification accuracy of 93.33% +/- 4.5% for the ResNet-34 architecture and 91.43% +/- 5.8% for the DenseNet-121 model. Furthermore, the implementation of 8-pass Test-Time Augmentation (TTA) yielded a robust mean accuracy of 88.31%, ensuring diagnostic stability during inference. By maintaining an accuracy-generalization gap of less than 0.04, this framework proves that high predictive performance can be achieved without sacrificing interpretability.
Mar 6, 2026

Optimizing 3D Diffusion Models for Medical Imaging via Multi-Scale Reward Learning

Diffusion models have emerged as powerful tools for 3D medical image generation, yet bridging the gap between standard training objectives and clinical relevance remains a challenge. This paper presents a method to enhance 3D diffusion models using Reinforcement Learning (RL) with multi-scale feedback. We first pretrain a 3D diffusion model on MRI volumes to establish a robust generative prior. Subsequently, we fine-tune the model using Proximal Policy Optimization (PPO), guided by a novel reward system that integrates both 2D slice-wise assessments and 3D volumetric analysis. This combination allows the model to simultaneously optimize for local texture details and global structural coherence. We validate our framework on the BraTS 2019 and OASIS-1 datasets. Our results indicate that incorporating RL feedback effectively steers the generation process toward higher quality distributions. Quantitative analysis reveals significant improvements in Fréchet Inception Distance (FID) and, crucially, the synthetic data demonstrates enhanced utility in downstream tumor and disease classification tasks compared to non-optimized baselines.
Mar 6, 2026

TumorChain: Interleaved Multimodal Chain-of-Thought Reasoning for Traceable Clinical Tumor Analysis

Accurate tumor analysis is central to clinical radiology and precision oncology, where early detection, reliable lesion characterization, and pathology-level risk assessment guide diagnosis and treatment planning. Chain-of-Thought (CoT) reasoning is particularly important in this setting because it enables step-by-step interpretation from imaging findings to clinical impressions and pathology conclusions, improving traceability and reducing diagnostic errors. Here, we target the clinical tumor analysis task and build a large-scale benchmark that operationalizes a multimodal reasoning pipeline, spanning findings, impressions, and pathology predictions. We curate TumorCoT, a large-scale dataset of 1.5M CoT-labeled VQA instructions paired with 3D CT scans, with step-aligned rationales and cross-modal alignments along the trajectory from findings to impression to pathology, enabling evaluation of both answer accuracy and reasoning consistency. We further propose TumorChain, a multimodal interleaved reasoning framework that tightly couples 3D imaging encoders, clinical text understanding, and organ-level vision-language alignment. Through cross-modal alignment and iterative interleaved causal reasoning, TumorChain grounds visual evidence, aggregates conclusions, and issues pathology predictions after multiple rounds of self-refinement, improving traceability and reducing hallucination risk. Experiments show consistent improvements over strong baselines in lesion detection, impression generation, and pathology classification, and demonstrate strong generalization on the DeepTumorVQA benchmark. These results highlight the potential of multimodal reasoning for reliable and interpretable tumor analysis in clinical practice. Detailed information about our project can be found on our project homepage at https://github.com/ZJU4HealthCare/TumorChain.
Mar 2, 2026

MAP-Diff: Multi-Anchor Guided Diffusion for Progressive 3D Whole-Body Low-Dose PET Denoising

Low-dose Positron Emission Tomography (PET) reduces radiation exposure but suffers from severe noise and quantitative degradation. Diffusion-based denoising models achieve strong final reconstructions, yet their reverse trajectories are typically unconstrained and not aligned with the progressive nature of PET dose formation. We propose MAP-Diff, a multi-anchor guided diffusion framework for progressive 3D whole-body PET denoising. MAP-Diff introduces clinically observed intermediate-dose scans as trajectory anchors and enforces timestep-dependent supervision to regularize the reverse process toward dose-aligned intermediate states. Anchor timesteps are calibrated via degradation matching between simulated diffusion corruption and real multi-dose PET pairs, and a timestep-weighted anchor loss stabilizes stage-wise learning. At inference, the model requires only ultra-low-dose input while enabling progressive, dose-consistent intermediate restoration. Experiments on internal (Siemens Biograph Vision Quadra) and cross-scanner (United Imaging uEXPLORER) datasets show consistent improvements over strong CNN-, Transformer-, GAN-, and diffusion-based baselines. On the internal dataset, MAP-Diff improves PSNR from 42.48 dB to 43.71 dB (+1.23 dB), increases SSIM to 0.986, and reduces NMAE from 0.115 to 0.103 (-0.012) compared to 3D DDPM. Performance gains generalize across scanners, achieving 34.42 dB PSNR and 0.141 NMAE on the external cohort, outperforming all competing methods.
Feb 27, 2026

3D Modality-Aware Pre-training for Vision-Language Model in MRI Multi-organ Abnormality Detection

Vision-language models (VLMs) show strong potential for complex diagnostic tasks in medical imaging. However, applying VLMs to multi-organ medical imaging introduces two principal challenges: (1) modality-specific vision-language alignment and (2) cross-modal feature fusion. In this work, we propose MedMAP, a Medical Modality-Aware Pretraining framework that enhances vision-language representation learning in 3D MRI. MedMAP comprises a modality-aware vision-language alignment stage and a fine-tuning stage for multi-organ abnormality detection. During the pre-training stage, the modality-aware encoders implicitly capture the joint modality distribution and improve alignment between visual and textual representations. We then fine-tune the pre-trained vision encoders (while keeping the text encoder frozen) for downstream tasks. To this end, we curated MedMoM-MRI3D, comprising 7,392 3D MRI volume-report pairs spanning twelve MRI modalities and nine abnormalities tailored for various 3D medical analysis tasks. Extensive experiments on MedMoM-MRI3D demonstrate that MedMAP significantly outperforms existing VLMs in 3D MRI-based multi-organ abnormality detection. Our code is available at https://github.com/RomantiDr/MedMAP.
Feb 25, 2026

Enhancing Renal Tumor Malignancy Prediction: Deep Learning with Automatic 3D CT Organ Focused Attention

Accurate prediction of malignancy in renal tumors is crucial for informing clinical decisions and optimizing treatment strategies. However, existing imaging modalities lack the necessary accuracy to reliably predict malignancy before surgical intervention. While deep learning has shown promise in malignancy prediction using 3D CT images, traditional approaches often rely on manual segmentation to isolate the tumor region and reduce noise, which enhances predictive performance. Manual segmentation, however, is labor-intensive, costly, and dependent on expert knowledge. In this study, a deep learning framework was developed utilizing an Organ Focused Attention (OFA) loss function to modify the attention of image patches so that organ patches attend only to other organ patches. Hence, no segmentation of 3D renal CT images is required at deployment time for malignancy prediction. The proposed framework achieved an AUC of 0.685 and an F1-score of 0.872 on a private dataset from the UF Integrated Data Repository (IDR), and an AUC of 0.760 and an F1-score of 0.852 on the publicly available KiTS21 dataset. These results surpass the performance of conventional models that rely on segmentation-based cropping for noise reduction, demonstrating the frameworks ability to enhance predictive accuracy without explicit segmentation input. The findings suggest that this approach offers a more efficient and reliable method for malignancy prediction, thereby enhancing clinical decision-making in renal cancer diagnosis.
Feb 25, 2026

Axial-Centric Cross-Plane Attention for 3D Medical Image Classification

Abridged: Clinicians commonly interpret 3D medical images by examining multiple anatomical planes rather than relying on volumetric views. In clinical CT workflows, the axial plane often serves as the primary diagnostic reference, while the auxiliary planes provide complementary spatial context. However, many existing 3D deep learning approaches either process volumetric data holistically or assign equal importance to all planes, failing to reflect this asymmetric, axial-centric interpretation strategy. To address this, we propose an axial-centric cross-plane attention architecture for 3D medical image classification that models asymmetric dependencies between anatomical planes. The architecture employs large-scale axial CT images pretrained MedDINOv3 as a frozen feature extractor for axial, coronal, and sagittal planes. RICA blocks and intra-plane transformer encoders capture plane-specific positional and contextual information, while axial-centric cross-plane transformer encoders selectively condition axial representations on complementary auxiliary representations. Experiments on six datasets from the MedMNIST3D benchmark show that the proposed method consistently outperforms existing 3D and multi-plane models in ACC and AUC. A lightweight variant, AC-Tiny, achieves competitive performance with substantially fewer trainable parameters, suggesting that architectural design contributes more to performance gains than increased model scale. Ablation studies further validate the importance of axial-centric querying, QKV allocation, directional cross-plane fusion, residual-free cross-attention, and classification head design. Slice-level Grad-CAM visualizations demonstrate that the model identifies diagnostically relevant regions across all planes. These findings highlight the value of aligning architectural design with clinical interpretation workflows for robust 3D medical image analysis.
Feb 20, 2026

Exploiting Completeness Perception with Diffusion Transformer for Unified 3D MRI Synthesis

Missing data problems, such as missing modalities in multi-modal brain MRI and missing slices in cardiac MRI, pose significant challenges in clinical practice. Existing methods rely on external guidance to supply detailed missing-state information for instructing generative models to synthesize missing MRIs. However, manual indicators are not always available or reliable in real-world scenarios due to the unpredictable nature of clinical environments. Moreover, these explicit masks are not informative enough to provide guidance for improving semantic consistency. In this work, we argue that generative models should infer and recognize missing states in a self-perceptive manner, enabling them to better capture subtle anatomical and pathological variations. Towards this goal, we propose CoPeDiT, a shared completeness-perception framework for 3D MRI synthesis, following a common conditioning strategy with task-specific instantiations for different missing-data scenarios. Specifically, we incorporate dedicated pretext tasks into our tokenizer, CoPeVAE, empowering it to learn completeness-aware discriminative prompt tokens, and design MDiT3D, a specialized diffusion transformer architecture for 3D MRI synthesis that effectively uses the completeness-aware prompt tokens as guidance to enhance semantic consistency in 3D space. Comprehensive evaluations on three large-scale MRI datasets demonstrate that CoPeDiT consistently improves upon state-of-the-art methods across diverse missing patterns, yielding high-fidelity and structurally consistent MRI synthesis. Our code is available at https://github.com/JK-Liu7/CoPeDiT.
Feb 20, 2026

3DMedAgent: Unified Perception-to-Understanding for 3D Medical Analysis

3D CT analysis spans a continuum from low-level perception to high-level clinical understanding. Existing 3D-oriented analysis methods adopt either isolated task-specific modeling or task-agnostic end-to-end paradigms to produce one-hop outputs, impeding the systematic accumulation of perceptual evidence for downstream reasoning. In parallel, recent multimodal large language models (MLLMs) exhibit improved visual perception and can integrate visual and textual information effectively, yet their predominantly 2D-oriented designs fundamentally limit their ability to perceive and analyze volumetric medical data. To bridge this gap, we propose 3DMedAgent, a unified agent that enables 2D MLLMs to perform general 3D CT analysis without 3D-specific fine-tuning. 3DMedAgent coordinates heterogeneous visual and textual tools through a flexible MLLM agent, progressively decomposing complex 3D analysis into tractable subtasks that transition from global to regional views, from 3D volumes to informative 2D slices, and from visual evidence to structured textual representations. Central to this design, 3DMedAgent maintains a long-term structured memory that aggregates intermediate tool outputs and supports query-adaptive, evidence-driven multi-step reasoning. We further introduce the DeepChestVQA benchmark for evaluating unified perception-to-understanding capabilities in 3D thoracic imaging. Experiments across over 40 tasks demonstrate that 3DMedAgent consistently outperforms general, medical, and 3D-specific MLLMs, highlighting a scalable path toward general-purpose 3D clinical assistants.Code and data are available at https://github.com/jinlab-imvr/3DMedAgent.
Feb 19, 2026

MeDUET: Disentangled Unified Pretraining for 3D Medical Image Synthesis and Analysis

Self-supervised learning (SSL) and diffusion models have respectively advanced representation learning and generative modeling for high-dimensional 3D visual data, yet they are often developed as separate paradigms. Their unification remains challenging under multi-source heterogeneity, as anatomical content must be preserved for analysis while acquisition-related style varies across centers and affects synthesis. In this paper, we propose MeDUET, a 3D Medical image Disentangled UnifiEd PreTraining framework in the variational autoencoder latent space. MeDUET formulates unified pretraining as an empirical factor identifiability problem, aiming to learn domain-invariant content factors for anatomy and domain-specific style factors for appearance. To improve factor separation, MeDUET first uses token demixing with a standard adversarial domain regularizer to establish basic content-style specialization, and further introduces Mixed Factor Token Distillation and Swap-invariance Quadruplet Contrast to reduce mixed-region factor leakage and organize factor spaces with factor-wise invariance and discriminability. With these learned factors, MeDUET transfers effectively to both synthesis and analysis, yielding higher fidelity, faster convergence, and better controllability for synthesis, while achieving competitive or superior domain generalization and label efficiency on diverse datasets, tasks, and modalities. Overall, MeDUET shows that multi-source heterogeneity can serve as useful supervision, with disentanglement providing an effective interface for unifying 3D medical image synthesis and analysis. Our code is available at https://github.com/JK-Liu7/MeDUET.
Feb 18, 2026

OmniCT: Towards a Unified Slice-Volume LVLM for Comprehensive CT Analysis

Computed Tomography (CT) is one of the most widely used and diagnostically information-dense imaging modalities, covering critical organs such as the heart, lungs, liver, and colon. Clinical interpretation relies on both slice-driven local features (e.g., sub-centimeter nodules, lesion boundaries) and volume-driven spatial representations (e.g., tumor infiltration, inter-organ anatomical relations). However, existing Large Vision-Language Models (LVLMs) remain fragmented in CT slice versus volumetric understanding: slice-driven LVLMs show strong generalization but lack cross-slice spatial consistency, while volume-driven LVLMs explicitly capture volumetric semantics but suffer from coarse granularity and poor compatibility with slice inputs. The absence of a unified modeling paradigm constitutes a major bottleneck for the clinical translation of medical LVLMs. We present OmniCT, a powerful unified slice-volume LVLM for CT scenarios, which makes three contributions: (i) Spatial Consistency Enhancement (SCE): volumetric slice composition combined with tri-axial positional embedding that introduces volumetric consistency, and an MoE hybrid projection enables efficient slice-volume adaptation; (ii) Organ-level Semantic Enhancement (OSE): segmentation and ROI localization explicitly align anatomical regions, emphasizing lesion- and organ-level semantics; (iii) MedEval-CT: the largest slice-volume CT dataset and hybrid benchmark integrates comprehensive metrics for unified evaluation. OmniCT consistently outperforms existing methods with a substantial margin across diverse clinical tasks and satisfies both micro-level detail sensitivity and macro-level spatial reasoning. More importantly, it establishes a new paradigm for cross-modal medical imaging understanding. Our project is available at https://github.com/ZJU4HealthCare/OmniCT.
Feb 17, 2026

Scaling Ultrasound Volumetric Reconstruction via Mobile Augmented Reality

Accurate volumetric characterization of lesions is essential for oncologic diagnosis, risk stratification, and treatment planning. While imaging modalities such as Computed Tomography provide high-quality 3D data, 2D ultrasound (2D-US) remains the preferred first-line modality for breast and thyroid imaging due to cost, portability, and safety factors. However, volume estimates derived from 2D-US suffer from high inter-user variability even among experienced clinicians. Existing 3D ultrasound (3D-US) solutions use specialized probes or external tracking hardware, but such configurations increase costs and diminish portability, constraining widespread clinical use. To address these limitations, we present Mobile Augmented Reality Volumetric Ultrasound (MARVUS), a resource-efficient system designed to increase accessibility to accurate and reproducible volumetric assessment. MARVUS is interoperable with conventional ultrasound (US) systems, using a foundation model to enhance cross-specialty generalization while minimizing hardware requirements relative to current 3D-US solutions. In a user study involving experienced clinicians performing measurements on breast phantoms, MARVUS yielded a substantial improvement in volume estimation accuracy (mean difference: 0.469 cm3) with reduced inter-user variability (mean difference: 0.417 cm3). Additionally, we prove that augmented reality (AR) visualizations enhance objective performance metrics and clinician-reported usability. Collectively, our findings suggests that MARVUS can enhance US-based cancer screening, diagnostic workflows, and treatment planning in a scalable, cost-conscious, and resource-efficient manner. Usage video demonstration available (https://youtu.be/m4llYcZpqmM).
Feb 17, 2026

Training-Free Zero-Shot Anomaly Detection in 3D Brain MRI with 2D Foundation Models

Zero-shot anomaly detection (ZSAD) has gained increasing attention in medical imaging as a way to identify abnormalities without task-specific supervision, but most advances remain limited to 2D datasets. Extending ZSAD to 3D medical images has proven challenging, with existing methods relying on slice-wise features and vision-language models, which fail to capture volumetric structure. In this paper, we introduce a fully training-free framework for ZSAD in 3D brain MRI that constructs localized volumetric tokens by aggregating multi-axis slices processed by 2D foundation models. These 3D patch tokens restore cubic spatial context and integrate directly with distance-based, batch-level anomaly detection pipelines. The framework provides compact 3D representations that are practical to compute on standard GPUs and require no fine-tuning, prompts, or supervision. Our results show that training-free, batch-based ZSAD can be effectively extended from 2D encoders to full 3D MRI volumes, offering a simple and robust approach for volumetric anomaly detection.
Oct 29, 2025

MedForj: An open, large-scale foundational generative prior for high-resolution 3D brain MRI

This work introduces MedForj, a suite of 3D foundational generative priors based on diffusion models. The MedForj models were trained on 72,65972{,}659 1~mm isotropic 3D T1T_1-weighted MRI human brain image volumes from 38,17438{,}174 subjects, drawn from a curated corpus of 80,67580{,}675 volumes from 42,50642{,}506 subjects spanning 3838 publicly available datasets. These training images were manually inspected to exclude those with poor quality and excessive pathology, and otherwise were minimally processed. The models include six different diffusion training strategies: rectified flow, latent diffusion rectified flow, flow matching, velocity prediction, clean prediction, and noise prediction. Image samples produced by each of these models were compared to each other and against real, ground truth data under downstream segmentation distributions, FID, five inverse problems, and blind human inspection in an observer study. Flow matching was the strongest strategy overall, achieving the best inverse problem solving results at 28.8028.80~dB PSNR and 0.8740.874 SSIM averaged over the five forward problems, the highest rate of reconstructions judged real by blind human raters at 72.6%72.6\%, and the closest per-structure match to real segmented anatomy in a permutation test. It was not best everywhere: rectified flow produced the most convincing unconditional samples in the observer study and the best FID, and the latent rectified-flow model achieved the smallest joint distributional distance to real anatomy. No other strategy, however, performed consistently well across all four evaluations. We therefore recommend flow matching as the default MedForj prior, while releasing every strategy so that the choice can be revisited per application. All model weights and corresponding code are publicly available at https://github.com/piksl-research/medforj.
Aug 25, 2025

Wound3DAssist: A Practical Framework for 3D Wound Assessment

Managing chronic wounds remains a major healthcare challenge, with clinical assessment often relying on subjective and time-consuming manual documentation methods. Although 2D digital videometry frameworks have aided wound measurement, these approaches struggle with perspective distortion, a limited field of view, and an inability to capture wound depth, especially in anatomically complex or curved regions. To overcome these limitations, we present Wound3DAssist, a practical framework for 3D wound assessment using monocular consumer-grade videos. Our framework generates 3D wound models from short handheld recordings captured using consumer-grade devices, enabling non-contact, automatic measurements from reconstructed multi-view surfaces. We integrate 3D reconstruction, wound segmentation, tissue classification, and periwound analysis into a modular workflow. We evaluate Wound3DAssist across digital models with known geometry, silicone phantoms, and real patients. Results show that the framework supports high-quality wound bed visualization, approximately millimeter-scale surface reconstruction accuracy in the evaluated clinical cases, and multi-view wound-tissue composition analysis. Full assessments are completed in under 20 minutes, demonstrating feasibility for a research framework intended for future clinical workflow evaluation.
Jul 28, 2025

Endoscopic Depth Estimation Based on Deep Learning: A Survey

Endoscopic depth estimation is a critical technology for improving the safety and precision of minimally invasive surgery. It has attracted considerable attention from researchers in medical imaging, computer vision, and robotics. Over the past decade, a large number of methods have been developed. Despite the existence of several related surveys, a comprehensive overview focusing on recent deep learning-based techniques is still limited. This paper endeavors to bridge this gap by comprehensively reviewing the state-of-the-art literature. Specifically, we provide a thorough survey of the field from three key perspectives: data, methods, and applications. Firstly, at the data level, we describe the acquisition process of publicly available datasets. Secondly, at the methodological level, we introduce both monocular and stereo deep learning-based approaches for endoscopic depth estimation. Thirdly, at the application level, we identify the specific challenges and corresponding solutions for the clinical implementation of depth estimation technology, situated within concrete clinical scenarios. Finally, we outline potential directions for future research, such as domain adaptation, real-time implementation, and the synergistic fusion of depth information with sensor technologies, thereby providing a valuable starting point for researchers to engage with and advance the field toward clinical translation.
Jul 15, 2025

Trexplorer Super: Topologically Correct Centerline Tree Tracking of Tubular Objects in CT Volumes

Tubular tree structures, such as blood vessels and airways, are essential in human anatomy and accurately tracking them while preserving their topology is crucial for various downstream tasks. Trexplorer is a recurrent model designed for centerline tracking in 3D medical images but it struggles with predicting duplicate branches and terminating tracking prematurely. To address these issues, we present Trexplorer Super, an enhanced version that notably improves performance through novel advancements. However, evaluating centerline tracking models is challenging due to the lack of public datasets. To enable thorough evaluation, we develop three centerline datasets, one synthetic and two real, each with increasing difficulty. Using these datasets, we conduct a comprehensive evaluation of existing state-of-the-art (SOTA) models and compare them with our approach. Trexplorer Super outperforms previous SOTA models on every dataset. Our results also highlight that strong performance on synthetic data does not necessarily translate to real datasets. The code and datasets are available at https://github.com/RomStriker/Trexplorer-Super.
Jun 29, 2025

Region-Aware Multimodal Large Language Model via SlowFast Tokenization and Pseudo-Mask Guidance for 3D CT Report Generation

Current CT report generation frameworks predominantly rely on global feature representations, often failing to capture region-specific details and potentially missing certain abnormalities. To overcome this limitation, we propose MedRegion-CT, a region-focused multimodal large language model framework featuring three key innovations. First, we revisit the SlowFast strategy to jointly model global and fine-grained information and adapt it to the medical domain via a Region-based SlowFast Tokenizer that extracts tokens guided by clinically meaningful regions. Second, generated pseudo-masks guide the model to attend to diagnostically important anatomical regions, facilitating a systematic understanding of the overall scan context. Third, quantitative lesion information, including size, diameter, and spatial location, is encoded as structured textual prompts, enabling context-aware and clinically informed report generation. To enable rigorous evaluation, we validate our framework on multi-institutional structured report generation benchmarks. Experimental results demonstrate that MedRegion-CT achieves state-of-the-art performance, outperforming existing approaches in both linguistic quality and clinical accuracy. All code is publicly available at: https://github.com/babbu3682/MedRegion-CT.
May 22, 2025

Render-FM: Feedforward Model for Real-time Photorealistic Volumetric Rendering

Photorealistic volumetric rendering of CT scans greatly benefits clinical workflows, yet neural approaches such as Neural Radiance Fields (NeRF) and 3D Gaussian Splatting (3DGS) require prohibitive per-scan optimization (hours for NeRF, about 30 minutes for 3DGS), making them impractical in clinical settings. We propose Render-FM, a feedforward model that eliminates this bottleneck by directly regressing 6D Gaussian Splatting (6DGS) parameters from a CT volume in a single 2.8-second forward pass, a 500x speedup over per-scan optimization. To bridge the domain gap between natural scene reconstruction and medical volumetric rendering, we introduce Anatomy-Guided Priming (AGP), which incorporates segmentation masks and transfer functions as structural and appearance priors, information that existing Gaussian splatting methods overlook. Built on an nnU-Net-inspired 3D U-Net trained on diverse CT scans, Render-FM predicts per-voxel 6DGS parameters and supports immediate real-time rendering. Unlike per-scan methods, it generalizes to unseen anatomies, novel transfer functions, and enables compositional organ visualization with zero additional preparation time. Optional 89-second fine-tuning further improves quality, surpassing per-scan optimized baselines. Project page: https://gaozhongpai.github.io/renderfm/.
Nov 23, 2024

Improving Factuality of 3D Brain MRI Report Generation with Paired Image-domain Retrieval and Text-domain Augmentation

Acute ischemic stroke (AIS) requires time-critical decision-making, where inaccurate interpretation of neuroimaging findings can lead to irreversible disability. Diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps from magnetic resonance imaging (MRI) are central to detecting acute infarction, yet generating factually reliable radiology reports directly from 3D MRI remains challenging due to the difficulty of learning robust cross-modal alignments between volumetric images and clinical text. We propose paired image-domain retrieval and text-domain augmentation (PIRTA), a retrieval-augmented generation framework that improves report factuality by avoiding explicit image-text alignment. PIRTA retrieves clinically similar 3D DWI/ADC volumes using a pretrained 3D vision encoder and leverages their paired clinician-authored reports to ground large language model (LLM)-based report generation. Experiments on multi-institutional in-house data, a held-out external privacy-preserving cohort, and the public ISLES benchmark demonstrate that PIRTA achieves strong image-domain retrieval performance and consistently improves ischemic-territory accuracy, a clinically grounded surrogate for report factuality, compared to direct image-to-text baselines. These results indicate that retrieval-grounded generation provides a scalable and reliable paradigm for producing factually consistent radiology reports from complex 3D brain MRI. Source code is available at https://github.com/jhlee0619/PIRTA.
Sep 18, 2024

Scale-specific auxiliary multi-task contrastive learning for deep liver vessel segmentation

Extracting hepatic vessels from abdominal images is of high interest for clinicians since it allows to divide the liver into functionally-independent Couinaud segments. In this respect, an automated liver blood vessel extraction is widely summoned. Despite the significant growth in performance of semantic segmentation methodologies, preserving the complex multi-scale geometry of main vessels and ramifications remains a major challenge. This paper provides a new deep supervised approach for vessel segmentation, with a strong focus on representations arising from the different scales inherent to the vascular tree geometry. In particular, we propose a new clustering technique to decompose the tree into various scale levels, from tiny to large vessels. Then, we extend standard 3D UNet to multi-task learning by incorporating scale-specific auxiliary tasks and contrastive learning to encourage the discrimination between scales in the shared representation. Promising results, depicted in several evaluation metrics, are revealed on the public 3D-IRCADb dataset.
May 17, 2024

3D Vessel Reconstruction from Sparse-View Dynamic DSA Images via Vessel Probability Guided Attenuation Learning

Digital Subtraction Angiography (DSA) is one of the gold standards for vascular disease diagnosis. With the help of a contrast agent, time-resolved 2D DSA images deliver comprehensive blood flow information and can be utilized to reconstruct 3D vessel structures for medical assessment. Current commercial DSA systems typically require hundreds of scanning views to perform reconstruction, resulting in substantial radiation exposure. In this study, we propose a neural rendering-based optimization framework tailored for high-quality sparse-view DSA reconstruction to reduce radiation dosage. Our approach, termed vessel probability guided attenuation learning, represents DSA imaging as a complementary weighted combination of static and dynamic attenuation fields, with the weights derived from the time-independent vessel probability field. Functioning as a foreground mask, vessel probability provides proper gradients for both static and dynamic fields adaptive to different scene types. This mechanism enables self-supervised decomposition between static backgrounds and dynamic contrast agent flow, and significantly improves reconstruction quality. Our model is trained by minimizing the discrepancy between synthesized projections and real captured DSA images. We further employ two training strategies to improve reconstruction quality: (1) coarse-to-fine progressive training for better geometry and (2) temporal perturbed rendering loss for temporal consistency. Experimental results have demonstrated high-quality 3D vessel reconstruction and 2D DSA image synthesis.