Motor Imagery

Recent momentum

emerging

4 papers in the last 28 days · 0.1% of indexed attention

Twelve weeks of publication activity for this topic as it is defined today.

Weekly history

Recent digests

What was published in this topic, kept on the site without email delivery.

Period ending 2026-09-21

3 new papers

A weekly snapshot of new work published in Motor Imagery.

25 papers

Latest in Motor Imagery

Sep 14, 2026cs.LG

FRIST: FMRI Representation Informed Shared-space Training Improves EEG-only Individual-Finger BCI Decoding

Finger-level motor decoding is important for naturalistic brain-computer interface (BCI) control, yet individual-finger decoding from scalp electroencephalography (EEG) remains challenging because finger representations are spatially close in the sensorimotor cortex and blurred by volume conduction. Leveraging the high spatial resolution of functional MRI (fMRI), we introduce fMRI Representation-Informed Shared-Space Training (FRIST), a two-stage EEG decoding framework that first learns fMRI-informed spectral projections from simultaneous EEG-fMRI recordings and then uses fMRI-derived class geometry to guide residual refinement of EEG predictions. FRIST transfers information across recordings through shared finger labels without requiring paired trials and uses only EEG at inference. We evaluated 12 able-bodied participants during movement execution (ME) and motor imagery (MI) under two-class and three-class chronological session-held-out decoding simulating the online scenario. Using EEGNet as the EEG feature extractor, FRIST increased group average accuracy from 66.93% to 74.53% for two-class ME, from 44.83% to 56.58% for three-class ME, from 80.78% to 85.63% for two-class MI, and from 60.93% to 69.90% for three-class MI compared with the EEG-only EEGNet baseline. FRIST is also shown to improve EEG-only decoding when the target participant's own fMRI data were unavailable. FRIST also generalized across multiple EEG decoding backbones, reaching 87.40% in two-class MI and 72.54% in three-class MI with EEG Conformer as the EEG feature extractor. These findings indicate that fMRI provide useful spatial constraints for EEG representation learning. FRIST improves noninvasive EEG-based finger-level BCI decoding, offering a multimodal strategy for integrating the spatial specificity of fMRI with real-time applicability of EEG.
Jintao Zhang, Yidan Ding, Joshua Kosnoff +3
Sep 14, 2026cs.HC

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

The growing use of electroencephalography (EEG) motivates automated analysis that is accurate, transferable, and deployable on constrained hardware. Recent EEG foundation models learn general representations from large-scale pretraining, but their size and computational cost limit edge and wearable deployment. We introduce BRIDGE-EEG, an efficient multi-task EEG classification pipeline that preserves the benefits of pretraining while reducing model size. A unified preprocessing scheme maps heterogeneous recordings with different channel counts, montages, and sampling rates to a device-agnostic 62-channel time--frequency representation. We pretrain an SE-ResNet18 teacher (11.84 M parameters) with SimCLR on unlabeled EEG from five heterogeneous datasets, then compress it into SE-ResNet8 (1.56 M) and SE-ResNet4 (0.48 M) students using task-agnostic and task-specific distillation. We evaluate six benchmarks spanning abnormality detection, motor imagery, and emotion recognition. For abnormality detection and emotion recognition, the students achieve accuracy comparable to or better than several recent EEG foundation models with 10--1,000×\times more parameters. Motor imagery shows a remaining representation gap, highlighting the importance of pretraining diversity. Inference profiling on a server GPU, desktop CPU, and NVIDIA Jetson Orin Nano shows up to 3.0×\times lower edge energy per inference (15.64 mJ vs. 46.67 mJ). The compact models further support future deployment on MCU-class wearables.
Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu +2
Sep 14, 2026cs.RO

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.
Hyungseok Ryu, Pilwon Hur
Aug 31, 2026cs.CE

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499±\pm0.009), whereas REVE-base reached 0.847±\pm0.194 and outperformed REVE-large (0.806±\pm0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464±\pm0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.
Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
Aug 13, 2026cs.LG

EEG Decoding Using CNN and LSTM Network

Motor imagery (MI) brain--computer interfaces (BCIs) have emerged as a promising approach for establishing flexible communication pathways between the human brain and external devices , particularly for individuals affected by stroke or neurodegenerative disorders. Reliable decoding of motor-imagery electroencephalography (MI-EEG) remains challenging because EEG recordings contain substantial noise and exhibit complex, weakly informative relationships with the underlying brain activity. Although deep learning provides an effective means of learning representations directly from EEG signals, its application to MI-EEG feature learning remains comparatively limited. This study introduces a hybrid deep-learning architecture that integrates a convolutional neural network (CNN) with a bidirectional long short-term memory (bi-LSTM) network. The CNN is used to learn high-level spatial and temporal representations directly from raw MI-EEG recordings, whereas the bi-LSTM models temporal dependencies and relationships among the extracted features. The proposed approach is evaluated using both a publicly available dataset and a privately acquired dataset obtained with an EEG acquisition system. The experimental results indicate that the CNN&bi-LSTM architecture provides robust performance for both two- and three-class motor-imagery classification and demonstrates promising subject-independent decoding capability across the evaluated methods.
Athanasios Karagounis
Aug 5, 2026cs.LG

Rectifying Geometric Misalignment: Online Source-Free Adaptation for Class-Imbalanced EEG

Electroencephalography (EEG) based Brain-Computer Interfaces (BCIs) often require unsupervised domain adaptation (UDA) to generalize across subjects and sessions. While Riemannian alignment methods like the Riemannian Centering Transformation (RCT) are effective for handling covariate shifts, they implicitly assume balanced class priors. However, in realistic online BCI scenarios, the label distributions vary dynamically (label shift), causing standard alignment techniques to geometrically misalign the target data distributions. In this work, we propose OSPDIM (Online SPD manifold information maximization), a source-free online UDA framework designed to address label shifts on the Riemannian manifold. OSPDIM introduces a manifold-constrained bias parameter into the tangent space mapping, which is optimized via information maximization to correct the geometric skew caused by imbalanced data streams. Unlike offline methods relying on global batch statistics, OSPDIM estimates and corrects geometric bias on-the-fly. Simulations on 2D SPD matrices visually demonstrate that OSPDIM successfully rectifies the misalignment where standard centering fails. Extensive experiments on multiple motor imagery datasets show that OSPDIM significantly outperforms standard Riemannian baselines, particularly in challenging online adaptation scenarios with severe class imbalance, offering a robust solution for practical, plug-and-play BCI systems.
Shiwen Chu, Shanglin Li, Motoaki Kawanabe +1
Jul 26, 2026cs.CV

ATCNet-CIAM for Multi-Session Motor Imagery EEG Signal Classification

Motor imagery (MI)-based electroencephalography is widely used in non-invasive brain--computer interfaces (BCIs), but robust decoding remains challenging due to inter-subject variability and cross-session non-stationarity. This work proposes ATCNet-CIAM, an enhanced attention temporal convolutional network that integrates a lightweight channel-integrated attention module (CIAM) into the ATCNet framework to improve channel-spatial feature representation for MI decoding. The proposed model is evaluated on BCI Competition IV-2a, BCI Competition IV-2b, and the multi-day WBCIC-MI dataset under standard, within-session, and cross-session protocols. Experimental results show that ATCNet-CIAM achieves 86.32% accuracy on BCI IV-2a and 87.96% on BCI IV-2b under the standard protocol, while reaching 89.46% and 83.64% in the within-session WBCIC-MI on 2C and 3C, respectively. The proposed framework consistently improves classification stability and robustness under session-varying conditions, and ablation study confirms the complementary contribution of the proposed architectural components.
Le Huu Son Hai, Nguyen Chi Hai, Truong Viet Vu +3
Jul 25, 2026cs.LG

Bayesian Complete-Pooling in Cross-Subject Classification for Motor Imagery Electroencephalogram

Brain-computer interfaces (BCIs) have long sought calibration-free operation, but classifiers are typically benchmarked by discrimination alone, blind to whether predicted probabilities are well calibrated - a meaningful gap given nonstationary electroencephalogram (EEG) signals and the risk of overconfident point-estimate classifiers under distribution shift. We conducted a large-scale study contrasting Bayesian complete-pooling models against frequentist baselines for cross-subject, left-hand versus right-hand motor imagery EEG classification across 20 datasets. Six frequentist pipelines were each paired with an analogous Bayesian pipeline sharing identical feature engineering, fit via Markov chain Monte Carlo posterior sampling. Our primary metric was the Brier score, decomposed into reliability and resolution, alongside AUROC for discrimination and Shannon entropy for sharpness. Each metric was analyzed via random-effects meta-analysis (REML, Knapp-Hartung adjustment), verified by leave-one-out influence analysis. Bayesian complete-pooling produced statistically but not practically significant improvements in reliability and increases in predictive uncertainty (lower sharpness); Brier score, resolution, and discrimination showed no significant differences. Between-study heterogeneity was low across all metrics, though the reliability result was sensitive to leave-one-out removal. We additionally profiled computational cost, finding that Bayesian pipelines consumed roughly thirteen times more energy than their frequentist counterparts, a cost that remains modest relative to common household appliances. These results suggest that Bayesian complete-pooling alone offers limited practical benefit for cross-subject motor imagery classification, and that partial-pooling across subjects and sessions is a more promising direction for future work.
Ethan Davis
Jul 24, 2026q-bio.NC

Subject-Level Heterogeneity in EEG Motor Imagery Decoding: A Large-Scale Benchmark and Portfolio-Based Reduction of the Search Space

Robust EEG motor imagery decoding remains limited by strong inter-individual variability, making it difficult to identify pipelines that generalize across users. We present a large-scale, standardized within-session benchmark of decoding pipelines across three public datasets: Cho2017 (52 subjects), PhysionetMI (109 subjects), and Zhou2016 (4 subjects). Using a common MOABB LeftRightImagery setting, two frequency bands (8-15 Hz and 8-30 Hz), and a broad combination of feature extraction, preprocessing, and classification steps, we analyzed 216,714 raw evaluation rows, which after structured aggregation yielded 44,928, 109,000, and 4,192 subject-level observations respectively. Covariance tangent-space projection (cov-tgsp) and Common Spatial Patterns (CSP) consistently defined the strongest methodological families, though their relative ordering was dataset-dependent. On Cho2017, the best family-level mean accuracy came from cov-tgsp in 8-30 Hz (0.712 +/- 0.140), whereas Zhou2016 favored CSP (0.832 +/- 0.121 in 8-15 Hz). These aggregate rankings concealed substantial subject-level heterogeneity: 42 distinct winning pipelines across 52 Cho2017 subjects, and 93 across 109 PhysionetMI subjects. We then used the benchmark as an empirical performance landscape for building compact portfolios of pipelines of size K. Several construction procedures were compared, including a ranking-based Top-K Mean heuristic and search-based strategies. Results were broadly consistent, with Top-K Mean giving the best trade-off. A single best global pipeline already retained 94.2% of the oracle in Cho2017 and 81.8% in PhysionetMI; at K = 12, oracle retention rose to 96.5% and 90.0%. The landscape is therefore subject-dependent, and this heterogeneity can be exploited through compact portfolios that make personalization more feasible.
Xavier Vasques, Paul Barbaste, Olivier Oullier
Jul 22, 2026cs.CV

Generative Augmentation for EEG Motor Imagery Classification: A Class-Conditional VAE with Cycle-Consistent Decoder Refinement

We investigate whether a generative model can supply useful synthetic motor-imagery (MI) electroencephalography (EEG) trials that improve the accuracy of independent downstream classifiers. We train a class-conditional variational autoencoder (CVAE) with an integrated latent classifier on the Zhou motor-imagery dataset, using the learned per-class prior as a generator: sampling the prior for a given label and decoding it into a synthetic, label-consistent signal. A constraint on the covariance matrix of the generated data encourages preservation of covariance structure, and the model is trained with a schedule that alternates ordinary VAE training with a decoder-focused phase that sharpens the generative pathway used for augmentation. We measure the effect of adding synthetic trials to the training set under two evaluation protocols -- within-user (pooled 60/20/20 split across subjects) and cross-user (leave-one-subject-out, LOSO) -- across four representative EEG classification pipelines: Common Spatial Patterns with Linear Discriminant Analysis (CSP+LDA), tangent-space features with a Support Vector Machine (TGSP+SVM), Minimum Distance to Riemannian Mean (MDM), and a neural network based on EEGNetv4 (henceforth EEGNet). Results are aggregated across independent augmentation draws, random seeds (within-user), or leave-one-subject-out folds (cross-user), with uncertainty reported as 95% confidence intervals (Student's tt-distribution) computed over per-seed/per-fold averages. We find that synthetic EEG from the CVAE is most credible as a source of class-structured, covariance-like data rather than as a substitute for real raw EEG: it can raise the point estimate for MDM, but the broader augmentation claim remains conservative -- observed gains are small and classifier-dependent.
Matei Moldoveanu, Alain Sirois, Claire Ben Ali +2
Jul 13, 2026cs.AI

Learning Residual Kinematic Corrections for Continuous Neural Decoding via Reinforcement Learning

Decoding continuous three-dimensional (3D) motor imagery (MI) using non-invasive electroencephalography (EEG)-based brain--computer interfaces (BCIs) remains challenging due to signal variability and residual decoding errors. Deep learning architectures such as convolutional neural network--long short-term memory (CNN--LSTM) models can capture spatial and temporal dynamics for continuous kinematic decoding; however, systematic residual errors persist in predicted trajectories. We propose a two-stage decoding framework that applies reinforcement learning (RL) to perform residual kinematic correction on the outputs of a CNN--LSTM decoder (CNN--LSTM--RL). The RL agent is trained offline without direct EEG input and instead operates on predicted kinematic trajectories to optimize movement accuracy relative to target trajectories. Decoding performance was quantified using Pearson correlation coefficients (rr) and Root Mean Square Errors (RMSE) along the x,yx, y, and zz axes. Compared to CNN--LSTM applied alone, CNN--LSTM--RL improved the mean correlation from 0.50760.5076 to 0.71810.7181 (p=0.0005p = 0.0005) in 2D and from 0.64200.6420 to 0.77800.7780 (p=0.0059p = 0.0059) in VR, with relative gains of 41.5%41.5\% and 21.2%21.2\%, respectively. Correspondingly, RMSE was reduced from 0.08900.0890 to 0.05320.0532 (2D, p<0.0001p < 0.0001) and from 0.07140.0714 to 0.04410.0441 (VR, p<0.0001p < 0.0001), representing relative reductions of 40.2%40.2\% and 38.2%38.2\%. These findings demonstrate that this scalable framework enhances 3D BCI MI decoding by correcting kinematic errors via offline residual RL without extra neural data, advancing neurorehabilitation, prosthetics, and virtual interaction.
Jiamian Li, Niall McShane, Attila Korik +6
Jul 3, 2026cs.LG

Stacked LoRA for Subject-Adaptive EEG Foundation Models in Motor Imagery Decoding

Electroencephalography (EEG) decoding for brain-computer interfaces (BCIs) faces a major challenge: substantial inter-subject variability limits effective cross-subject generalization. Consequently, practical systems still rely largely on subject-specific models trained from scratch and requiring individual recalibration. EEG foundation models have recently emerged as a promising alternative; however, even large pretrained models cannot simply be used as fixed feature extractors and still require additional adaptation before they can be reliably applied to downstream tasks. In this work, we address this challenge through targeted adaptation strategies. Building on recent EEG foundation models such as REVE, LaBraM, and LUNA, we examine the impact of different low-rank adaptation strategies on motor imagery classification. We propose a framework that structurally decouples subject-invariant knowledge from subject-specific neural signatures: the low-rank update at each adapted layer is split into a Global adapter, trained jointly across all subjects, and Subject-Specific adapters, each absorbing individual variability. To assess the contribution of each path, we compare three adaptation strategies: (i) subject-specific LoRA (ii) global LoRA and (iii) stacked LoRA, combining both Global and Subject Specific adapters. Experiments on BCI Competition IV-2a, PhysioNet Motor Imagery, and the clinical Zuo2025 benchmark show that Stacked LoRA effectively mitigates inter-subject variability, achieving the best accuracy in the large majority of backbone and dataset combinations. Our analysis further reveals that the optimal balance between the global and subject-specific paths depends on the target population: a shared adapter is sufficient for large, diverse cohorts, whereas subject-specific adaptation is decisive under the high inter-session variability of clinical recordings.
Aymen Sarhane, Fouad Lbakali, Mouad Souissi +2
Jun 29, 2026cs.AI

Temporal Feature Extractors in EEG Foundation Models: A Controlled Comparison Including a Pretrained Time-Series Model

Electroencephalography (EEG) foundation models aim to learn generalizable representations from large-scale brain recordings. However, the role of temporal feature extractors and whether pretrained time-series foundation models (TSFMs) can be effectively transferred to this setting remains underexplored. We conduct a controlled comparison of three temporal feature extraction strategies, including a linear baseline, a convolutional encoder, and a frozen pretrained TSFM (MOMENT), within a unified EEG foundation model. We evaluate their impact on representation quality using two downstream tasks: motor imagery and emotion recognition. Results reveal different trends across the evaluated benchmarks. On the motor imagery dataset, simple temporal representations perform competitively, whereas the emotion dataset benefits from richer temporal modeling. Although not specifically adapted to EEG, the pretrained TSFM serves as an effective temporal feature extractor, suggesting that general-purpose time-series representations can be transferred as frozen temporal feature extractors within EEG foundation models.
Ayşe Betül Yüce, Chris Joey Leffler, Sarun Varghese +2
Jun 23, 2026cs.HC

Average Rankings Mask Per-Subject Optimality: A Friedman-Nemenyi Benchmark of EEG Motor-Imagery BCI Decoders

Electroencephalography (EEG) is the dominant non-invasive modality for brain-computer interfaces (BCIs), yet reliable decoding of motor imagery is hampered by inter- and intra-individual variability. A recurring claim is that one decoding pipeline, most often a spatial or Riemannian method, is broadly preferable. We test the weakest version of that claim under the most favourable conditions. Using the Mother of All BCI Benchmarks (MOABB) framework, we evaluated 1,056 decoding configurations (feature extractor x scaler x classifier), >340,000 subject-level model fits, across three public left-versus-right motor-imagery datasets (PhysionetMI, 109 participants; Cho2017, 52; Zhou2016, 4) and two frequency bands (8-15 Hz, 8-30 Hz). Every model is fit and tested within a single session of a single participant, the easiest regime, giving every pipeline its best chance. We apply the statistics standard for multi-classifier comparison: Friedman omnibus tests, Nemenyi critical-difference analysis and Wilcoxon signed-rank tests with effect sizes. Covariance tangent-space projection (cov-tgsp) and Common Spatial Patterns (CSP) are the strongest families, but their ordering is dataset-dependent and, on the largest and most heterogeneous cohort (PhysionetMI), statistically indistinguishable (Nemenyi p = 0.27; Kendall's W = 0.11). At the individual level the single best pipeline is optimal for only 35% of PhysionetMI participants, and nonlinear descriptors are best for roughly one third; matching pipeline to participant adds about seven accuracy points over the best fixed choice. The ranking is not an artefact of dimensionality, and classifier and scaler choices are secondary to the feature representation. Even in the easiest regime, no single pipeline dominates: a lower bound on the personalization problem and a quantitative case for participant-aware model selection rather than a universal decoder.
Xavier Vasques, Paul Barbaste, Olivier Oullier
Jun 15, 2026cs.LG

Learning aligned EEG representations with subject-specific encoders

Cross-subject EEG decoding promises more training data, but it also exposes neural networks to strong inter-subject distribution shifts. We study whether task supervision and architecture alone can learn subject-aligned representations. We replace a shared EEG encoder with subject-specific encoders followed by a common classifier, and compare this hybrid model with standard EEGNet, AttentionBaseNet, and CTNet baselines with Euclidean Alignment (EA) on three motor-imagery datasets and one motor-execution dataset. EA improves shared encoders by recentering subject covariances, whereas the hybrid encoder reduces reliance on EA: removing EA has little effect on validation-loss dynamics or latent-space organization, and both hybrid variants consistently outperform non-aligned shared baselines. Subject-specific heads increase class distinctiveness and place each subject close to its own latent manifold while improving within-subject class separation. However, on cross-subject classification, subject-specific heads hinder direct parameter transfer to unseen subjects, motivating quantitative head selection and a brief calibration session. Although decoding gains depend on the dataset and backbone, our main findings concern that the sole use of architecture pressure promotes representation learning and alignment in a direction complementary to domain adaptation methods such as Euclidean Alignment. A per-subject low-rank adapter of only 2Cr parameters recover the full encoder's accuracy across five backbones and ranks r=1r=1 to 16, so the per-subject module can be compressed by two to three orders of magnitude.
Bruna J. Lopes, Gabriel Schwartz, Sylvain Chevallier +2
Jun 15, 2026cs.RO

An Augmented Reality Brain-Robot Interface for Generalist Robot Arm Manipulation

The integration of augmented reality (AR) and EEG-based brain-computer interfaces (BCIs) offers a promising path for enabling intuitive control of robots for assistive purposes. However, existing AR brain-robot interface (BRI) systems are often constrained to task-specific structures, limiting their utility in real-world environments. We present an AR BRI designed for generalist robot arm manipulation that combines gaze-based object selection with motor imagery action control. Our system uses eye-tracking for intuitive object targeting and context-aware visual overlays ("Place" and "Use") to guide the user through tasks within a shared autonomy framework. We evaluated the interface through a feasibility study with 18 healthy participants performing three multi-step activities of daily living: drinking, using a drawer, and operating an oven. Our results demonstrate that this interaction paradigm enables effective sequential task execution and high user engagement, achieving a "Good" usability rating (SUS > 70). These findings support the feasibility of the proposed interaction paradigm for complex BCI-driven robotic assistance, and motivate future evaluation with the intended target population. Project website: https://ar-bri-manip.github.io/.
Shangkai Zhang, Rousslan Fernand Julien Dossa, Luca Nunziante +2
May 28, 2026cs.HC

A Domain-Informed Multi-Objective Framework for EEG Channel Selection in Motor Imagery BCIs

Motor imagery (MI) classification using electroencephalography (EEG) signals is essential for advancing brain-computer interfaces (BCIs). Traditional EEG channel selection methods often face limitations, such as dependency on single-objective criteria and susceptibility to local optima. To address these challenges, this work proposes a multi-objective optimisation framework that employs non-dominated sorting genetic algorithm, multiple-objective particle swarm optimisation, and a multi-objective evolutionary algorithm based on decomposition. Our approach effectively balances spatial relevance, using a Gaussian kernel, and functional discriminability, which assesses intratrial task-related desynchronisation, thereby improving performance. We evaluated this framework on four EEG datasets: Physionet, OpenBMI, HighGamma, and BCIIV-2A. The proposed approach successfully identifies compact, relevant channel subsets concentrated around sensorimotor cortex regions linked to MI activity, addressing the prevalent challenges of dimensionality and complexity inherent to traditional techniques. Furthermore, the framework achieved classification performance of 87%, 71%, 75%, and 65% on the Physionet, OpenBMI, HighGamma, and BCIIV-2A datasets, respectively. By outperforming existing single-objective and accuracy-based methods, and those relying on fixed subsets, these findings demonstrate that this new multi-objective optimisation framework can enhance MI-based BCI performance while facilitating compact channel configurations with reduced computational complexity, making them better suited for wearable, portable, and real-time BCI applications.
Dekka Muni Kumar, Dhruba Jyoti Kalita, Yogesh Kumar Meena
May 28, 2026cs.AI

Benchmarking Positional Encoding Strategies for Transformer-Based EEG Foundation Models

Electroencephalography (EEG) is a widely used non-invasive technique for measuring brain activity in brain-computer interface (BCI) applications. Supervised EEG decoding models often struggle to generalize across tasks, subjects, and datasets, motivating transformer-based EEG foundation models trained with self-supervised learning. Since transformers are permutation-invariant, they require explicit positional information. Unlike textual tokens, EEG electrodes are spatially distributed across the scalp, raising the question of how electrode positions should be encoded in transformer-based EEG models. In this study, we benchmark five positional encoding strategies within the CBraMod backbone and evaluate them under linear probing and fine-tuning protocols on motor imagery classification and emotion recognition. Our results show that no single strategy consistently outperforms across tasks. Spherical Positional Encoding (SPE) yields strong representations for motor imagery but underperforms on emotion recognition, while Asymmetric Conditional Positional Encoding (ACPE) demonstrates more consistent performance across tasks. These findings suggest that the optimal positional encoding strategy is task-dependent, with no universal solution across EEG decoding scenarios.
Ayse Betul Yuce, Sebastian Stober
May 11, 2026cs.LG

Explainability of Recurrent Neural Networks for Enhancing P300-based Brain-Computer Interfaces

Brain-Computer Interfaces (BCIs) based on P300 event-related potentials offer promising applications in health, education, and assistive technologies. However, challenges related to inter- and intra-subject variability and the explainability of Deep Learning (DL) models limit their practical deployment. In this work, we present the Post-Recurrent Module (PRM), an additional layer designed to improve both performance and transparency, incorporated into a Recurrent Neural Network (RNN) architecture for classifying P300 signals from EEG data. Our approach enables a dual analysis of spatio-temporal signals through both global and local explainability techniques, allowing us not only to identify the most relevant brain regions and critical time intervals involved in classification, but also to interpret model decisions in terms of spatio-temporal EEG patterns consistent with well-stablished neurophysiological descriptions of the P300. Experimental results show a 9% improvement in performance over state of the art, while also revealing the importance of inter- and intra-subject variability, in alignment with established neuroscience literature. By making model decisions transparent and efficient, we present a framework for explainable EEG-based models. This framework is not limited to more efficient P300 detection, but can be generalized to a wide range of EEG-based tasks. Its ability to identify key spatial and temporal features makes it suitable for applications such as motor imagery, steady-state visual evoked potentials, and even cognitive workload assessment.
Christian Oliva, Vinicio Changoluisa, Francisco B Rodríguez +1
May 11, 2026cs.LG

CFSPMNet: Cross-subject Fourier-guided Spatial-Patch Mamba Network for EEG Motor Imagery Decoding in Stroke Patients

Motor imagery electroencephalography (MI-EEG) decoding offers a non-invasive route for post-stroke rehabilitation, but cross-patient use remains difficult because pathological neural reorganization changes task-related EEG dynamics, aperiodic activity, local excitability, cross-regional coordination, and trial-level brain-state context. This makes source-learned MI representations unreliable for unseen patients. To address this problem, we propose CFSPMNet, a cross-patient adaptation framework that models post-stroke MI-EEG as latent neural-state organization. CFSPMNet combines a Fourier-Reorganized State Mamba Network (FRSM) with Shared-Private Prototype Matching (SPPM). FRSM represents each trial as a latent physiological token sequence, reorganizes token states in the Fourier domain, and uses Fourier-derived trial context to guide Mamba state-space propagation. SPPM improves target pseudo-label updating by combining semantic confidence with shared-private physiological consistency, filtering confident but physiologically inconsistent target predictions. Leave-one-subject-out experiments on two stroke MI-EEG datasets show that CFSPMNet outperforms representative CNN-, Transformer-, Mamba-, and adaptation-based baselines, achieving average accuracies of 68.23% on XW-Stroke and 73.33% on 2019-Stroke, with gains of 5.63 and 8.25 percentage points over the strongest competitors. Ablation, sensitivity, feature-alignment, pseudo-label selection, and neurophysiological visualization analyses further support the roles of Fourier-domain token-state reorganization and calibrated pseudo-label updating. These results suggest that latent neural-state modeling can improve rehabilitation-oriented cross-patient BCI decoding. Code is available at https://github.com/wxk1224/CFSPMNet.
Xiangkai Wang, Yun Zhao, Dongyi He +5
May 5, 2026q-bio.QM

A Machine Learning Framework for EEG-Based Prediction of Treatment Efficacy in Chronic Neck Pain

Chronic neck pain is a leading cause of disability worldwide, and current treatment selection remains largely trial and error. We present a machine learning framework that uses electroencephalography to predict treatment efficacy in patients with chronic neck pain, with the goal of supporting individualized therapy and reducing the burden on healthcare systems. The framework centers on a rigorous data preprocessing stage tailored to the characteristics of each EEG recording type. For resting-state EEG, the preprocessing pipeline comprises baseline signal removal, bad channel identification and exclusion, re-referencing, bandpass and notch filtering, Independent Component Analysis, and power spectral density analysis. For motor execution and motor imagery recordings, the same initial steps are applied, after which signals are aligned to trigger events so that event-related desynchronization (ERD) and event-related synchronization (ERS) can be quantified. Synchronously recorded electromyography data are bandpass filtered and smoothed with a moving average, then correlated with the corresponding EEG channels to characterize the EEG EMG relationship during attempted movement. In parallel, we performed an extensive literature review of machine learning models applied to clinical EEG (763 records initially screened, 16 patient and 47 healthy-control studies retained), to inform the post-processing strategy. Through this combined preprocessing and review effort, we aim to develop a robust predictive model that can support personalized healthcare strategies in chronic pain management.
Xiru Wang, Aiden Li, Hongzhao Tan +3
Apr 17, 2026cs.CV

PA-TCNet: Pathology-Aware Temporal Calibration with Physiology-Guided Target Refinement for Cross-Subject Motor Imagery EEG Decoding in Stroke Patients

Stroke patient cross-subject electroencephalography (EEG) decoding of motor imagery (MI) brain-computer interface (BCI) is essential for motor rehabilitation, yet lesion-related abnormal temporal dynamics and pronounced inter-patient heterogeneity often undermine generalization. Existing adaptation methods are easily misled by pathological slow-wave activity and unstable target-domain pseudo-labels. To address this challenge, we propose PA-TCNet, a pathology-aware temporal calibration framework with physiology-guided target refinement for stroke motor imagery decoding. PA-TCNet integrates two coordinated components. The Pathology-aware Rhythmic State Mamba (PRSM) module decomposes EEG spatiotemporal features into slowly varying rhythmic context and fast transient perturbations, injecting the fused pathological context into selective state propagation to more effectively capture abnormal temporal dynamics. The Physiology-Guided Target Calibration (PGTC) module constructs source-domain sensorimotor region-of-interest templates, imposing physiological consistency constraints and dynamically refining target-domain pseudo-labels, thereby improving adaptation reliability. Leave-one-subject-out experiments on two independent stroke EEG datasets, XW-Stroke and 2019-Stroke, yielded mean accuracies of 66.56% and 72.75%, respectively, outperforming state-of-the-art baselines. These results indicate that jointly modeling pathological temporal dynamics and physiology-constrained pseudo-supervision can provide more robust cross-subject initialization for personalized post-stroke MI-BCI rehabilitation. The implemented code is available at https://github.com/wxk1224/PA-TCNet.
Xiangkai Wang, Yun Zhao, Dongyi He +5
Nov 24, 2025cs.LG

Geometry-Aware Deep Congruence Networks for Manifold Learning in Cross-Subject Motor Imagery

Cross-subject motor imagery decoding remains a fundamental challenge in EEG-based brain-computer interfaces due to substantial inter-subject variability. Recent approaches have leveraged Riemannian geometry by representing EEG signals as covariance matrices on the symmetric positive definite (SPD) manifold. However, existing methods primarily focus on manifold-based representations while largely overlooking subject-specific variations in covariance dispersion and orientation. In this work, we address these challenges through geometry-aware congruence transformations and propose three complementary models: (i) Discriminative Congruence Transform (DCT), (ii) Deep Linear DCT (DLDCT), and (iii) Deep DCT-UNet (DDCT-UNet). The proposed models are evaluated both as manifold alignment modules for downstream classifiers and as end-to-end discriminative architectures optimized via cross-entropy with a custom logistic regression head. Experiments on challenging cross-subject motor imagery benchmarks demonstrate consistent improvements in transductive decoding performance, achieving 2-3% higher accuracy than strong baselines. These results highlight the effectiveness of geometry-aware congruence learning for mitigating inter-subject variability in EEG decoding.
Sanjeev Manivannan, Chandra Shekar Lakshminarayan
Oct 17, 2025cs.CV

Cortical-SSM: A Deep State Space Model for Motor Imagery Decoding from EEG Signals

Classification of electroencephalogram (EEG) signals obtained during motor imagery (MI) has substantial application potential, including communication assistance and rehabilitation support for patients with motor impairments. These signals remain inherently susceptible to physiological artifacts (e.g., eye blinking and swallowing), which pose persistent challenges. Although Transformer-based approaches for classifying EEG signals have been widely adopted, they often struggle to capture fine-grained dependencies within them. To overcome these limitations, we propose Cortical-SSM, a novel architecture that extends deep state space models to capture integrated dependencies of EEG signals across temporal, spatial, and frequency domains. We validated our method across two large-scale public MI EEG datasets containing more than 50 subjects. Our method outperformed baseline methods on both benchmarks. Furthermore, visual explanations derived from our model indicate that it effectively captures neurophysiologically relevant regions of EEG signals. These results indicate that Cortical-SSM provides a robust and interpretable alternative to attention-based architectures for MI EEG decoding. By enabling physiologically grounded feature learning, our method advances the reliability of subject-independent EEG classification and supports the development of practical and clinically deployable brain-computer interface systems.
Shuntaro Suzuki, Shunya Nagashima, Komei Sugiura
Sep 30, 2025cs.LG

EEG-based AI-BCI Wheelchair Advancement: Transformer-Based Learning with Motor Imagery for Brain Computer Interface

This paper presents an Artificial Intelligence (AI) integrated approach to Brain-Computer Interface (BCI)-based wheelchair development, utilizing a motor imagery right-left-hand movement mechanism for control. The system is designed to simulate wheelchair navigation based on motor imagery right and left-hand movements using electroencephalogram (EEG) data. A pre-filtered dataset, obtained from an open-source EEG repository, was segmented into arrays of 19x200 to capture the onset of hand movements. The data was acquired at a sampling frequency of 200Hz. The system integrates a Tkinter-based interface for simulating wheelchair movements, offering users a functional and intuitive control system. We propose TFormerEEG, a Transformer-driven deep learning architecture, for motor imagery EEG classification. The model achieves a test accuracy of 93.04% compared with various machine learning baseline models, including XGBoost, EEGNet, and an EEG-Deformer model. The TFormerEEG achieved a mean accuracy of 91.18% through stratified cross-validation, showcasing the effectiveness of this model.
Bipul Thapa, Biplov Paneru, Bishwash Paneru +1